Masimo Rad-67 9794 Kit, Spot-Check Pulse CO-Oximeter with SpHb

SKU: MAS-9794

The Masimo 9794 is the Rad-67 kit: a handheld spot-check Pulse CO-Oximeter that reads functional oxygen saturation (SpO2), pulse rate, perfusion index (Pi), and noninvasive total hemoglobin (SpHb), plus one rainbow M20 patient cable.12 It is a needle-free hemoglobin spot check, not a blood-sample meter, and not a carbon monoxide (SpCO) device.3 The SpHb sensor is not in this kit. Next Generation SpHb on the Rad-67 is available only with a compatible next-generation sensor, the rainbow DCI-mini SC-400 (Masimo 3798, 400 spot checks).24 We are an authorized Masimo distributor and supply the genuine, new Masimo 9794.

What's in the Masimo 9794 box

Masimo's catalog and the dealer quote itemize the kit as the monitor and one patient cable. Sensors must be ordered separately.12 Third-party listings sometimes add an AC adapter or describe the cable as an RD cable. Those descriptions conflict with Masimo's own kit line, so this list marks anything we have not seen on a Masimo packing list as "confirm."

Item Included in 9794? Source
Rad-67 handheld Pulse CO-Oximeter, with SpO2, pulse rate, perfusion index, and SpHb enabled Yes Masimo catalog 2024 Q3; quote 0057507612
One rainbow M20 patient cable (not an RC cable and not an RD cable) Yes Quote 00575076 ("rainbow M20"); catalog kit line12
Built-in rechargeable lithium-ion battery Yes, in the device LAB-10262D (up to 6 hours at the lowest indicator brightness with wireless off; about 6 hours to charge)3
rainbow DCI-mini SpHb sensor (3798 or 3799) No. Order separately. Catalog: "Sensors must be ordered separately." Next Generation SpHb is only available with the DCI-mini.24
Masimo AC power supply / adapter Confirm The operator's manual lists the AC power supply as part of the Rad-67 system, but the catalog kit line and the quote do not itemize it. Confirm it on the packing list before you depend on it.3

Which part number is which: 9794, 9825, 9826, 3798, and 3799

Authorized-distributor listings use more than one Rad-67 kit number. They are not interchangeable. We list 9794 and the 3798 sensor separately.

Part What it is Sensor included?
9794 Rad-67 kit: SpO2, pulse rate, perfusion index, SpHb, and one rainbow M20 patient cable. This page. No12
9825 Listed by authorized distributors as a Rad-67 kit that includes a DCI-mini with 200 spot checks (SC-200). Not this page, and not on our 2024 Q3 catalog extract. Yes, 200 checks, per those listings5
9826 Listed as a Rad-67 adult starter kit that includes a DCI-mini with 400 spot checks (SC-400). Not this page. Yes, 400 checks, per those listings5
3798 rainbow DCI-mini SC-400 reusable sensor only, 400 SpHb spot checks. Quote-only product page. This is the sensor26
3799 rainbow DCI-mini, 1,000 spot checks. A different sensor part, not this kit and not our 3798 page. This is the 1,000-check sensor7

SpHb and prehospital blood administration

In prehospital blood programs, the Rad-67 provides a fast, needle-free SpHb spot check that supports, but does not replace, the protocol's physiologic transfusion criteria and laboratory hemoglobin. SpHb should not on its own start, withhold, delay, or stop transfusion.38 Results can display in as few as 30 seconds when the DCI-mini is connected.4

The 2025 Prehospital Blood Transfusion Coalition civilian EMS guideline uses suspected hemorrhagic shock and vital-sign criteria, not an SpHb cutoff. Those criteria include systolic blood pressure below 90 mm Hg (below 100 mm Hg if the patient is 65 or older), or a weak or absent radial pulse; a heart rate of 100 or more that does not respond to initial interventions; and a shock index (heart rate divided by systolic pressure) greater than 1.0. They are elements of a clinical algorithm under medical direction, not independent reasons to transfuse every patient with an abnormal vital sign.8

Masimo's operator's manual is direct: do not use SpHb spot-check measurements as the sole basis for clinical decisions on blood transfusions. The labeled SpHb accuracy range is 8 to 17 g/dL and does not include values below 8 g/dL, which may be important when deciding whether to transfuse.3 SpHb is not intended to replace laboratory blood testing. Blood samples should be analyzed by laboratory instruments before clinical decision making.4 A normal initial hemoglobin also does not exclude major bleeding; published trauma guidance cautions against transfusing on hemoglobin alone and recommends repeat measurements.9

SpHb on the Rad-67 is indicated for adult patients only (18 years or older). It is not intended for pediatric patients, pregnant patients, or patients with renal disease. The device is not intended to measure SpHb on pregnant women.3

What the studies support, and what they do not

Finding Source How we use it
In a selected trauma group with laboratory Hb below 8 g/dL (70 patients, 184 paired readings), reported bias was +0.12 g/dL and limits of agreement were -0.56 to +0.79 g/dL. Gamal et al., Shock 201710 Supportive in a narrow, in-hospital, low-Hb sample. Not a prehospital whole-blood trial, and figures are often repeated from manufacturer summaries.
During critical-care air-transport training, SpHb was captured on 97.7% of ground readings and 97.2% of in-flight readings. Participants were healthy. Davis et al., Military Medicine 202411 Shows it is often possible to obtain a value during transport. This is feasibility, not accuracy in hemorrhaging patients.
In 23 combat casualties, reported bias was +0.3 +/- 1.6 g/dL, the signal was present 76% of the time, and trend direction agreed 86% of the time. PubMed 2750112012 Small sample at trauma hospitals, not in a moving ambulance. Average bias was small; individual error and signal gaps were not.
Some operating-room studies of continuous SpHb reported less red-cell use or earlier transfusion. PubMed-indexed in-hospital series13 In-hospital continuous monitoring, not a prehospital spot-check protocol.
An emergency-department study of the Rad-67 and DCI-mini in 650 patients found a bias of 0.146 g/dL and limits of agreement of -2.58 to 2.87 g/dL versus the hospital analyzer (Pearson 0.812). The authors asked for more research on transfusion and outcomes. Al Aseri et al., Am J Emerg Med 202214 ED spot-check agreement, not a prehospital transfusion trial.
A Level 1 trauma repeat study (218 paired measurements) found bias +0.5 g/dL and limits of agreement of -3.6 to +4.1 g/dL, and concluded SpHb was not suitable as an initial diagnostic tool for trauma hemoglobin assessment. Jost et al., J Surg Res 202115 Cite this limit. Individual errors can be several grams per deciliter.
In 711 trauma patients, adding SpHb values and trends did not significantly improve prediction of urgent transfusion over models that used conventional pulse-oximetry features. Galvagno et al., 201516 SpHb is not established as an independent field transfusion trigger.
A study of percutaneous hemoglobin reported that transfusion decisions based on SpHb would have been wrong in 27.1% of patients. Anaesthesiol Intensive Ther17 Threshold-based use misclassifies patients. Do not import a cutoff into EMS.
In patients at risk of hemorrhage, about 15% of measurements failed, and agreement with laboratory hemoglobin change was about 60%. DTIC ADA62676618 A downward or stable trend is not automatically reliable.
Low peripheral perfusion can degrade SpHb accuracy. Kondo, ESA 201319 This matters in the shock patients a blood program is meant to treat.

An ARMS of about 1 g/dL means roughly two-thirds of readings fall within 1 g/dL of the reference in a controlled study, not that every reading does.4

Cable compatibility: M20, RC, and RD

The Rad-67 uses a rainbow M20 patient cable. One is in the 9794 kit. Some 3798 listings still say the sensor "requires a rainbow RC series patient cable." That wording comes from older catalogs written for classic rainbow SET monitors. Do not buy an RC-1 or RC-4 for the Rad-67 just because a sensor page says "RC."220 Verify the full combination of monitor, cable, and sensor before use; an incorrect set can degrade performance or injure the patient.3 See also our Masimo part-number cross-reference.

Cable family Example part numbers Fits which monitor Fits which sensors Use with Rad-67 and 3798?
rainbow M20 4236 (M20-01, 1 ft), 4237 (M20-04, 4 ft) Rad-67 M20 port rainbow and M-LNCS sensors, including the DCI-mini Yes. This is the documented Rad-67 cable family.220
rainbow RC 2405 (RC-1), 2406 (RC-4), 2404 (RC-12), and EMS RC cables 4480 and 4481 Classic 20-pin rainbow monitors such as the Rad-57 and Radical-7 rainbow sensors, including the DCI-mini, on those monitors No, not on the Rad-67. Use RC when the 3798 is on a Rad-57 or similar classic rainbow SET device.2
RD rainbow SET M20 or MD20 RD M20 cables (for example 4255, 4256, 4257) and MD20 cables (for example 4072, 4073, 4792) RD or MD20 instrument connectors RD rainbow SET and LNCS-II sensors, not the DCI-mini No. "M20" in an RD cable name is not the same as rainbow M20. Do not substitute.20

Rad-67 compared with Rad-57, Rad-97, Pronto, and HemoCue

These are different tools. The table is factual, not a ranking. Choose the device that matches the job and the labeled parameters.

Rad-67 (9794) Rad-57 Rad-97 Pronto HemoCue Hb 801
Role Handheld spot-check Pulse CO-Oximeter for SpO2 and needle-free SpHb Handheld continuous Pulse CO-Oximetry; the usual Masimo tool for EMS carbon monoxide work when SpCO is enabled Compact continuous monitor, with family models that can add capnography or non-invasive blood pressure Earlier Masimo handheld SpHb spot-check platform Handheld hemoglobin meter that uses a blood sample
SpO2 and pulse rate Yes, spot-check Yes, continuous Yes, continuous Yes No
SpHb Yes, adult spot-check; Next Generation SpHb needs the DCI-mini, sold separately Available when that parameter is enabled Available when enabled Spot-check SpHb on that platform Invasive: about 10 uL of capillary or venous blood; labeled range 1.0 to 25.6 g/dL
SpCO Not a US feature on the 9794 Available on SpCO-configured kits Upgradeable on supported configurations Not the current EMS CO handheld of record No
Alarms and workflow No physiological alarms; touchscreen; stored, patient-tagged spot checks Continuous readings and trend memory Continuous trends, patient profiles, optional extra modules Spot-check handheld A blood-sample result, not a pulse-oximeter

If the assignment is firefighter or EMS carbon monoxide screening, see the Rad-57 collection. If you need rainbow sensors and cables more broadly, see rainbow sensors and rainbow cables.

Product Highlights

  • Spot-check SpO2, pulse rate, perfusion index, and SpHb on one handheld, with a color touchscreen, patient identifiers, and storage for up to 2,000 spot-check sessions.34
  • Masimo SET Measure-through Motion and Low Perfusion pulse oximetry for SpO2 and pulse rate.4
  • Next Generation SpHb when used with the DCI-mini; results display in as few as 30 seconds, with signal-quality indicators.4
  • Rechargeable lithium-ion battery, up to 6 hours at the lowest indicator brightness with wireless off, and about 6 hours to charge.3
  • Wireless printing of results at the point of care on a compatible printer.4

Specifications

Masimo Part Number 9794
SKU MAS-9794
Product Family Rad-67 Pulse CO-Oximeter
Device Type Handheld spot-check Pulse CO-Oximeter kit2
US parameters in this kit SpO2, pulse rate, perfusion index, SpHb2
SpO2 accuracy (DCI-mini, 70-100%) 2% ARMS no motion and low perfusion; 3% ARMS motion; adults, pediatrics, and infants4
Pulse rate accuracy (25-240 bpm) 3 bpm ARMS no motion and low perfusion; 5 bpm ARMS motion4
SpHb accuracy range 8-17 g/dL, adults only. Operator's manual: -1.82 to 2.07 g/dL (660 samples).3
SpHb resolution 0.1 g/dL3
Battery Lithium-ion, up to 6 hours; 6 hours charge time3
Display Backlit TFT LCD, 720 x 12803
Dimensions 7.6 x 3.2 x 0.9 in (19.4 x 8.2 x 2.4 cm)3
Weight 0.81 lb (0.37 kg) for the device3
Ingress IP243
Operating temperature 32 to 95 F (0 to 35 C)3
GTIN 00843997012812

Buying, lead time, and warranty

  • Authorized Masimo distributor. Units ship new, in original Masimo packaging, not refurbished.
  • Checkout asks for a clinical attestation before this order ships.
  • Lead time: Masimo quote 00575076 stated delivery in 2 to 4 weeks after receipt of order. That quote expired on 2026-09-28, so confirm the current lead time when you order.1
  • Warranty, as printed in the US operator's manual: Masimo warrants the Rad-67 hardware to the original end-user against defects in material and workmanship for 12 months, and the battery for 6 months, from the date the end-user obtained the product, subject to the exclusions in LAB-10262D. The remedy is repair or replacement at Masimo's option.3
  • We accept orders when the item is not on the shelf. Add MAS-9794 to your cart, or contact CustomerService@pacificbiomedical.com or 844.436.3526. We support net terms for agencies and hospitals and ship to all 50 states.

Directions for use and official documents

Frequently Asked Questions

What's included in the Masimo Rad-67 9794 kit? Does it include a DCI-mini SpHb sensor?

The 9794 kit includes the Rad-67 with SpO2, pulse rate, perfusion index, and SpHb, and one rainbow M20 patient cable.12 It does not include a DCI-mini sensor. Order 3798 (400 spot checks) separately if you want Next Generation SpHb. The AC power supply is part of the Rad-67 system in the manual; confirm it on the packing list.

How much does the Rad-67 cost, and what's the total cost with sensor and spot checks?

This 9794 kit is $1,215. The 3798 sensor is quote-only until we have a current dealer cost, so the combined total depends on that quote. Part 9826 is a different kit that, in authorized-distributor listings, already includes a 400-check DCI-mini; we are not listing 9826 on this page.

What is the difference between 9794, 9825, and 9826?

9794 is the Rad-67 with an M20 cable and no sensor. Authorized-distributor listings describe 9825 as a Rad-67 kit with a 200-check DCI-mini (SC-200) and 9826 as a Rad-67 adult starter kit with a 400-check DCI-mini (SC-400).5 Confirm the exact part number, the cable, and whether a sensor is included before you compare prices.

Does the Rad-67 measure SpCO or SpMet? Can it be upgraded?

Not on this US 9794 kit. US indications are SpO2, pulse rate, and adult SpHb. SpCO and SpMet appear as optional upgrades only in an international brochure that excludes the US and Canada.21 Confirm any upgrade with Masimo before you promise one. For field CO screening, use a Rad-57 kit that includes SpCO.

Rad-67 vs Rad-57 vs Rad-97: which is better for EMS?

They do different jobs. The Rad-67 is a spot-check device for needle-free SpHb and SpO2, with no physiological alarms. The Rad-57 is the usual Masimo handheld for continuous monitoring and, when configured, carbon monoxide (SpCO) work. The Rad-97 is a larger continuous monitor with optional capnography or blood-pressure models. See the comparison table above. A HemoCue Hb 801 is a different tool: it measures hemoglobin from a blood sample, not from a finger sensor.

Can SpHb be used to decide on prehospital blood transfusion or whole blood?

Not by itself. Use it as a fast, needle-free adjunct to the clinical picture, vital signs, and the service's approved protocol. The 2025 Prehospital Blood Transfusion Coalition guideline uses suspected hemorrhagic shock and vital-sign criteria, not an SpHb cutoff.8 Do not use SpHb as the sole basis for transfusion decisions, and do not wait on an SpHb value when hemorrhage resuscitation is already indicated.3 A normal or stable SpHb must not be used to withhold otherwise indicated blood.

How accurate is SpHb in trauma and EMS?

It depends on the study. A selected low-Hb trauma series reported tight limits of agreement, and an ED study of the Rad-67 found acceptable average agreement with laboratory hemoglobin.1014 A Level 1 trauma repeat study found limits of agreement from about -3.6 to +4.1 g/dL and concluded SpHb was not suitable for initial trauma hemoglobin assessment.15 Adding SpHb did not improve transfusion prediction in 711 trauma patients.16 Transport data show that a value can often be captured in flight, but that study used healthy trainees and did not test accuracy in bleeding patients.11 Treat SpHb as adjunctive.

What are SpHb's limitations vs lab hemoglobin, and what is the validated range?

SpHb does not replace laboratory hemoglobin.4 The labeled range is 8 to 17 g/dL and does not include values below 8 g/dL.3 Low perfusion, motion, and several clinical conditions can degrade accuracy.19 About two-thirds of readings in controlled studies fall within the published ARMS or limits of agreement, not every reading.

How many spot checks does the 3798 have, and what happens when they run out?

The 3798 is an SC-400 sensor, rated for 400 spot checks, not 400 unique patients. X-Cal stops the sensor once that rating is used up. Do not assume it will keep working as an SpO2-only sensor afterward.6 Replace it when the device reports that the sensor is expired or must be replaced.

What is the difference between 3798 and 3799 (400 vs 1,000)?

Both are rainbow DCI-mini reusable sensors. 3798 is the 400-spot-check (SC-400) version, which we list as quote-only. 3799 is the 1,000-spot-check version, a different part number that is not this kit and not our 3798 page.7

Which cable does the Rad-67 use: M20 or RC? Does the 3798 really need an RC cable?

The Rad-67 uses a rainbow M20 cable. One is in the 9794 kit. Replacement examples are 4236 (1 ft) and 4237 (4 ft).2 The "requires RC" line on some 3798 listings comes from older catalogs for classic rainbow SET monitors such as the Rad-57. Do not buy an RC cable for the Rad-67. Use an RC cable when the 3798 is connected to a Rad-57 or similar 20-pin rainbow monitor. Do not use an RD M20 or MD20 cable with the DCI-mini.20

Which monitors are compatible with the DCI-mini 3798?

The sensor directions for use say rainbow DCI-mini reusable sensors are for devices containing Masimo rainbow SET technology, version 7.4 or higher, or a licensed device, with the SpHb parameter enabled for hemoglobin readings.6 On a Rad-67, use the rainbow M20 cable. On a Rad-57 or other classic rainbow SET monitor, use a rainbow RC series cable. A matching plug is not enough; confirm the monitor, cable, sensor, and enabled parameters.

Can the Rad-67 be used on pediatric or pregnant patients, or patients with renal disease?

SpO2 and pulse rate may be used on adult and pediatric patients as labeled. SpHb is indicated for adults only and is not intended for pediatric patients, pregnant patients, or patients with renal disease. The manual lists pregnancy as a contraindication for SpHb measurement.3

Is the Rad-67 a continuous monitor? Does it have alarms?

No. It is a spot-check device. The manual states that it provides no physiological alarms and is not intended as an apnea monitor.3

How long does the battery last?

The built-in lithium-ion battery is rated for up to 6 hours at the lowest indicator brightness with wireless functions off, and about 6 hours to charge, per LAB-10262D.3 Runtime is shorter if the display is bright or wireless is on. The limited warranty on the battery is 6 months from the date the end-user obtained the product.

References

  1. Masimo. Quotation 00575076, Pacific Biomedical, 9794 Kit, Rad-67, including one rainbow M20 patient cable. Created 2026-07-01, expired 2026-09-28. Delivery stated as 2-4 weeks after receipt of order. Opened 2026-11-21.
  2. Masimo. Product Catalog 2024 Q3, PLM-10062P. Handheld Instruments, part 9794, Rad-67; Sensors, part 3798, rainbow DCI-mini SC-400; Cables, parts 4236 and 4237, rainbow M20. August 2024.
  3. Masimo. Rad-67 Pulse CO-Oximeter Operator's Manual, Spot-Check, for sale in the USA. LAB-10262D. Indications, contraindications, transfusion warning, specifications, limited warranty (12 months hardware, 6 months battery). https://techdocs.masimo.com/globalassets/techdocs/pdf/lab-10262d_master.pdf. Opened 2026-11-21.
  4. Masimo. Noninvasive Next Generation SpHb Technology / Rad-67 product information. PLM-11187A-0419 and PLM-11186B-0419, 2019. PLM-11187A. PLM-11186B. Opened 2026-11-21.
  5. Authorized-distributor listings for Masimo 9825 (Rad-67 with DCI-mini SC-200, 200 spot checks) and 9826 (Rad-67 adult starter kit with DCI-mini SC-400, 400 spot checks), including Discount Catheters, Concord Health Supply, MFI Medical, and Medequip Depot, as summarized in the 2026-11-21 Perplexity run (p01, p08). These kit numbers are not on our 2024 Q3 catalog extract. Opened 2026-11-21.
  6. Masimo. Directions for Use, rainbow DCI-mini Series Reusable SpHb and SpO2 Sensors. LAB-10263A-eIFU-0419. Includes rainbow SET version 7.4 or higher, X-Cal, and a one-year limited warranty to the initial buyer. https://techdocs.masimo.com/globalassets/techdocs/pdf/lab-10263a-eifu.pdf. Opened 2026-11-21.
  7. Masimo technical documents and DCI-mini product information list part IDs 3797, 3798, and 3799 in the rainbow DCI-mini series, with 3798 as the 400-spot-check SC-400 and 3799 as the 1,000-spot-check version (PLM-11188B; techdocs rainbow DCI-mini series index). techdocs index. Opened 2026-11-21.
  8. Prehospital Blood Transfusion Coalition. Clinical Practice Guideline for Civilian Emergency Medical Services, 2025. Physiologic criteria for transfusion; no SpHb cutoff. prehospitaltransfusion.org PDF. Opened 2026-11-21.
  9. Rossaint R, Afshari A, Bouillon B, et al. The European guideline on management of major bleeding and coagulopathy following trauma: sixth edition. Crit Care. 2023. doi:10.1186/s13054-023-04327-7. Opened 2026-11-21.
  10. Gamal M, et al. Evaluation of noninvasive hemoglobin monitoring in trauma patients with low hemoglobin. Shock. 2017. Figures as commonly summarized on Masimo SpHb Outcomes and related pages. Opened 2026-11-21.
  11. Davis WT, et al. Noninvasive hemoglobin monitoring during critical care air transport training. Mil Med. 2024;189(S3):448. Opened 2026-11-21.
  12. Accuracy of noninvasive hemoglobin monitoring in combat casualties. PubMed 27501120. Opened 2026-11-21.
  13. In-hospital continuous SpHb transfusion-management studies, including PMC4621711 and PMC13267314, as listed on Masimo SpHb Outcomes. Opened 2026-11-21.
  14. Al Aseri ZAA, Aldawood BA, Altamimi AA, et al. Accuracy of noninvasive hemoglobin level measurement in the emergency department. Am J Emerg Med. 2022. doi:10.1016/j.ajem.2022.11.012. Opened 2026-11-21.
  15. Jost G, et al. Evaluation of noninvasive hemoglobin measurements in trauma patients: a repeat study. J Surg Res. 2021. PubMed 34023577. Opened 2026-11-21.
  16. Galvagno SM Jr, Hu P, Yang S, et al. Accuracy of continuous noninvasive hemoglobin monitoring for the prediction of blood transfusion in trauma. 2015. PubMed 25753142. Opened 2026-11-21.
  17. Blood transfusion decisions cannot be based on percutaneous haemoglobin measurements. Anaesthesiol Intensive Ther. PMC10158438. Opened 2026-11-21.
  18. Accuracy of Noninvasive Hemoglobin Monitoring in Patients at Risk for Hemorrhage. Defense Technical Information Center, ADA626766. Opened 2026-11-21.
  19. Kondo. Influence of peripheral perfusion index on accuracy of noninvasive hemoglobin monitoring. ESA 2013. Masimo clinical-evidence PDF. Opened 2026-11-21.
  20. Masimo. SET and rainbow Sensor and Cable Compatibility, US. PLM-10747D. https://professional.masimo.com/siteassets/us/documents/pdf/plm-10747d-sales-tool-sensor-and-cable-compatibility-us.pdf. See also the 2026-11-21 cable-compatibility review citing rainbow M20 parts 4236 and 4237. Opened 2026-11-21.
  21. Masimo. Rad-67 product information, UK/international, PLM-10356C, 2018, which lists optional SpCO and SpMet and excludes the US and Canada. PLM-10356C. Opened 2026-11-21.
Item # Image Price Quantity

Masimo Rad-67 9794 Kit, Spot-Check Pulse CO-Oximeter with SpHb

MAS-9794

$1,215.00

ea

Authorized Masimo Distributor Genuine Masimo Product

Most items ship in 1 to 2 business days

Authorized Masimo Distributor
Genuine Masimo Product
Most items ship in 1 to 2 business days
Item # Image Description Quantity