CAT vs SAM XT vs SWAT-T: Choosing Tourniquets for EMS and Agency Kits
The C-A-T Gen 7 and the SAM XT are CoTCCC-recommended windlass tourniquets. The SWAT-T is an elastic wrap that is not on that list, and junctional devices cover the groin and armpit where a limb tourniquet cannot reach.
If you're stocking a limb tourniquet for an ambulance or a patrol car, the two windlass tourniquets on the Committee on Tactical Combat Casualty Care (CoTCCC) recommended list that Pacific Biomedical carries are the North American Rescue C-A-T Gen 7 and the metal-windlass SAM XT600.1 The SWAT-T is an elastic stretch-and-wrap device that isn't on that list, and its maker positions it for small limbs and for bleeding high in the groin or armpit where a windlass won't fit.2 After that, let your agency protocol and what your people actually train on make the call.
Exsanguination remains the leading cause of preventable death in trauma, and the American College of Surgeons Committee on Trauma, the American College of Emergency Physicians and NAEMSP put prehospital hemorrhage control in a joint position statement in 2023.3 Buying the device is the easy part. It works when the provider holding it has put that exact model on a real arm enough times that nobody has to think through the steps.
Tourniquets Side by Side
| Device | CoTCCC status | Design | Fit |
|---|---|---|---|
|
C-A-T Gen 7 North American Rescue, 30-0001 black, 30-0023 orange |
Recommended; Gen 6 acceptable until replaced1 | Windlass, single routing buckle, 1.5 in strap, 37.5 in open length4 | NAR says it works down to a pediatric-sized limb4 |
|
SAM XT600 and XT700 SAM Medical, metal or polymer windlass |
XT600 recommended (listed as SAM-XT); SAM does not claim it for the XT7001 | Windlass with an auto-locking TRUFORCE buckle5 | 5.75 to 32.5 in limb circumference6 |
|
SWAT-T Safeguard Medical |
Not listed1 | Elastic polyisoprene band: stretch, wrap and tuck2 | Small limbs, plus high inguinal and axillary bleeds, per the maker2 |
|
SAM Junctional Tourniquet SAM Medical, JT400-EN |
CoTCCC names no junctional product1 | Belt with inflatable target compression devices7 | Difficult inguinal and axillary bleeds, pelvic fracture immobilization8 |
|
AAJT-S Compression Works |
CoTCCC names no junctional product1 | Belt with a wedge-shaped inflatable bladder9 | Bleeding in the pelvis, inguinal area and axilla, pelvic fracture stabilization9 |
C-A-T Gen 7
The C-A-T is the windlass tourniquet a lot of us learned on. North American Rescue lists a 1.5 inch strap, a 37.5 inch open length and a weight of 2.7 ounces, with a single routing buckle, a windlass clip that locks from either side and a hook-and-loop strap that holds the windlass rod in place during movement.4
CoTCCC recommends the Gen 7 and accepts the Gen 6 until units come up for life-cycle replacement, so there's no reason to pull serviceable Gen 6 tourniquets off a rig tomorrow.1 North American Rescue states the C-A-T has been the Official Tourniquet of the U.S. Army since 2005, and it says the device works on a pediatric-sized limb.4
We carry the C-A-T Gen 7 in Tactical Black (30-0001) and Rescue Orange (30-0023), plus the blue Trainer (30-0033) for the training bag.
SAM XT600 and XT700
The SAM XT uses a TRUFORCE buckle that auto-locks at a set amount of circumferential force, and SAM says that takes out nearly all of the slack before you start turning the windlass.5 SAM lists a fit range of 5.75 to 32.5 inches of limb circumference.6
In a manikin study of 60 military medicine cadets, the SAM XT and the C-A-T Gen 7 left about the same amount of slack, roughly 5 mm, and controlled simulated hemorrhage at similar rates of 73.3% and 67.7%. The SOF Tactical Tourniquet Wide trailed both at 35%.10 Those are trainee numbers on a manikin, and neither device came close to 100% in that model, but it is one of the few studies that puts the two side by side under the same conditions.
SAM makes the XT with a metal windlass (XT600) or a polymer windlass (XT700). CoTCCC lists the SAM-XT under the XT600's NSN, and SAM claims the CoTCCC recommendation for the XT600 only, so buy the metal version when your protocol calls for a CoTCCC-recommended device.15
SWAT-T
The SWAT-T is a band of polyisoprene about 10.4 cm wide, with no windlass and no buckle.11 Safeguard Medical sells it as a wrap, a splint or a tourniquet, and positions it for small limbs, like a child's or a working K9's, and for bleeding high in the groin or armpit where a windlass tourniquet won't fit.2 It isn't on the CoTCCC recommended limb tourniquet list.1
All of the SWAT-T research comes from volunteers and models, not patients. In 16 volunteers, the wide SWAT-T needed less pressure to occlude arterial flow than the 3.8 cm C-A-T.11 In a small head-to-head on the leg, nine emergency medicine residents stopped distal arterial flow 89% of the time with the C-A-T Gen 7 and 67% of the time with the SWAT-T, and the SWAT-T took longer to apply, 23.1 seconds against 10.4.12
The band has shapes printed on it that change when it is stretched correctly. A study of students with minimal training found the SWAT-T could stop arterial flow, but occlusion came more often on arms than on legs, and the authors concluded that many appliers need some training to use it well.13
Small limbs are where the SWAT-T earns its place. In pediatric manikins and PVC pipe models, it tightened on every pipe, while no windlass tourniquet tightened on a pipe 5.75 inches around or smaller.14 That study measured whether the device could be tightened and secured. It didn't measure blood flow, so it doesn't show that the SWAT-T stops bleeding in a child.
Junctional Tourniquets for the Groin and Armpit
At the junctions, where the leg or arm meets the trunk, a limb tourniquet runs out of limb. CoTCCC doesn't recommend a specific junctional product and leaves the choice to any FDA device indicated for junctional hemorrhage control.1
The SAM Junctional Tourniquet (JT400-EN) is a belt with inflatable target compression devices.7 FDA cleared it in 2013 for battlefield and trauma use to control difficult bleeds in the inguinal and axilla areas and to immobilize a pelvic fracture, and its 510(k) summary describes use for up to 4 hours.8 The AAJT-S from Compression Works is a wedge-shaped bladder that compresses the lower abdomen, the groin or the axilla. Its 2023 clearance covers bleeding in the pelvis, inguinal area and axilla and pelvic fracture stabilization, with up to 1 hour of abdominal use and up to 4 hours of junctional use.9
The evidence is thinner here than for limb tourniquets. A 2019 meta-analysis of eight studies put the SAM Junctional Tourniquet's average effectiveness at 87% and the AAJT's abdominal application at 52%, and every one of those studies was done in healthy volunteers rather than patients.15 I think of these as tools for medics and flight crews, or for agencies with the training time to keep people current on them.
Strap Width: 1 Inch vs 1.5 Inch
CoTCCC removed the original 1 inch SOF Tactical Tourniquet from its recommendations and kept the 1.5 inch SOFTT-Wide.1 In 116 volunteers, wide blood flow restriction cuffs shut off arterial flow at a lower pressure than narrow cuffs, and in the tourniquet study above, the 10.4 cm SWAT-T needed less pressure than the 3.8 cm C-A-T.1611 The cuff study used exercise equipment rather than emergency tourniquets, so trust the direction of the finding more than the exact pressures.
Trainers and Live Units
North American Rescue makes a fully functioning C-A-T Gen 7 in blue so instructors and students can tell training devices apart from operational tourniquets at a glance.4 A trainer gets cranked down over and over in a class. Keep trainers in the training bag and live units sealed on the rig, and don't let one drift into the other's pouch. The C-A-T Trainer Blue (30-0033) makes that easy to police during rig checks.
Buying for an Agency
- Standardize. My bias is one windlass model on every rig and in every training bag. People fall back on what their hands know, and a mixed fleet means somebody meets an unfamiliar buckle on the worst call of the month.
- Color. Black and orange C-A-Ts are the same Gen 7 device.4 Pick by where it rides: black on a duty belt or a plate carrier, orange if it lives in a crowded jump bag.
- Carry. A tourniquet at the bottom of a bag doesn't help anybody. SAM makes a MOLLE holster for the SAM XT (XT100-TH-BK), and North American Rescue makes a rigid Gen 7 C-A-T case.
- Counterfeits. In September 2024 the U.S. International Trade Commission issued a general exclusion order barring the import of windlass tourniquets that infringe a C-A-T patent, on a complaint from Composite Resources and North American Rescue.17 Buy through an authorized distributor and be suspicious of a price that looks too good.
- Inspection and replacement. North American Rescue calls the C-A-T a single-use device with no shelf life as long as it stays unused, in its packaging and stored somewhere dry, dark and climate controlled.4 Replace any tourniquet that has been used on a patient, check packaging during rig checks and follow each maker's instructions for use.
For the bigger picture on how military trauma care found its way onto civilian rigs, see EMS History: 250 Years From the Battlefield to Prehospital Blood.
Frequently Asked Questions
Which tourniquets are TCCC recommended?
The CoTCCC limb tourniquet list includes the C-A-T Gen 7 (with the Gen 6 acceptable until replaced), RMT-T, SAM-XT, SOFTT-W, TMT, TX2 and TX3, plus the pneumatic EMT and TPT2 for medics and evacuation platforms rather than individual kits. The SWAT-T is not on the list.1
What is the difference between the CAT Gen 6 and Gen 7?
North American Rescue's Gen 7 uses a single routing buckle, a windlass clip that locks from either side and a windlass retention strap.4 CoTCCC recommends the Gen 7 and accepts the Gen 6 until units reach life-cycle replacement.1
Is the SWAT-T as effective as a CAT?
The evidence comes from volunteers and models. The SWAT-T occludes at a lower pressure, but in one nine-person leg study it stopped distal flow 67% of the time against 89% for the C-A-T Gen 7, and it is not CoTCCC recommended.121
Is a 1.5 inch tourniquet better than a 1 inch tourniquet?
CoTCCC dropped the 1 inch SOFTT and kept the 1.5 inch SOFTT-Wide, and volunteer studies show wider bands shut off arterial flow at lower pressure.116
Do tourniquets expire?
North American Rescue says an unused C-A-T in its packaging, stored dry, dark and climate controlled, has no shelf life. It is a single-use device, so once it goes on a patient it gets replaced.4 Check each maker's instructions for its own storage rules.
Shop the Tools
Pacific Biomedical carries the C-A-T Gen 7, SAM XT600 and XT700, SWAT-T, SAM Junctional Tourniquet and AAJT-S for EMS, fire and law enforcement agencies. For agency quantities, call (844) 436-3526 or email CustomerService@pacificbiomedical.com.
Shop tourniquets →References
- Committee on Tactical Combat Casualty Care. CoTCCC recommended devices and adjuncts. Joint Trauma System. Accessed November 14, 2026. https://books.allogy.com/web/tenant/8/books/f94aad5b-78f3-42be-b3de-8e8d63343866/
- Safeguard Medical. SWAT-T tourniquet. Safeguard Medical. Accessed November 14, 2026. https://safeguardmedical.com/products/swat-t%E2%84%A2-tourniquet
- Berry C, Gallagher JM, Goodloe JM, Dorlac WC, Dodd J, Fischer PE. Prehospital hemorrhage control and treatment by clinicians: a joint position statement. Prehosp Emerg Care. 2023;27(5):544-551. doi:10.1080/10903127.2023.2195487
- North American Rescue. Combat Application Tourniquet (C-A-T). North American Rescue. Accessed November 14, 2026. https://www.narescue.com/combat-application-tourniquet-c-a-t.html
- SAM Medical. SAM XT tourniquet (MW). SAM Medical. Accessed November 14, 2026. https://www.sammedical.com/products/sam-xt-tourniquet
- SAM Medical. SAM XT600 metal windlass product overview, AF-SXT600-SS-EN-07. SAM Medical; 2026. Accessed November 14, 2026. https://sammedical.app.box.com/s/ldea45zouenmzdfp8i8iy59lt1hudclw
- SAM Medical. SAM Junctional Tourniquet. SAM Medical. Accessed November 14, 2026. https://www.sammedical.com/products/sam-junctional-tourniquet
- US Food and Drug Administration. 510(k) premarket notification K131561: SAM Junctional Tourniquet. July 24, 2013. Accessed November 14, 2026. https://www.accessdata.fda.gov/cdrh_docs/pdf13/K131561.pdf
- US Food and Drug Administration. 510(k) premarket notification K221661: Abdominal Aortic and Junctional Tourniquet, Stabilized (AAJT-S). March 3, 2023. Accessed November 14, 2026. https://www.accessdata.fda.gov/cdrh_docs/pdf22/K221661.pdf
- Katsnelson S, Oppenheimer J, Gerrasi R, et al. Assessing the current generation of tourniquets. Mil Med. 2020;185(3-4):e377-e382. doi:10.1093/milmed/usz392
- Wall PL, Duevel DC, Hassan MB, Welander JD, Sahr SM, Buising CM. Tourniquets and occlusion: the pressure of design. Mil Med. 2013;178(5):578-587. doi:10.7205/MILMED-D-12-00490
- Ellis J, Morrow MM, Belau A, et al. The efficacy of novel commercial tourniquet designs for extremity hemorrhage control: implications for spontaneous responder every day carry. Prehosp Disaster Med. 2020;35(3):276-280. doi:10.1017/S1049023X2000045X
- Wall PL, Welander JD, Singh A, Sidwell RA, Buising CM. Stretch and wrap style tourniquet effectiveness with minimal training. Mil Med. 2012;177(11):1366-1373. doi:10.7205/milmed-d-12-00150
- El-Sherif N, Lowndes B, Franz W, Hallbeck MS, Belau S, Sztajnkrycer MD. Sweating the little things: tourniquet application efficacy in two models of pediatric limb circumference. Mil Med. 2019;184(suppl 1):361-366. doi:10.1093/milmed/usy283
- Smith S, White J, Wanis KN, Beckett A, McAlister VC, Hilsden R. The effectiveness of junctional tourniquets: a systematic review and meta-analysis. J Trauma Acute Care Surg. 2019;86(3):532-539. doi:10.1097/TA.0000000000002159
- Loenneke JP, Fahs CA, Rossow LM, et al. Effects of cuff width on arterial occlusion: implications for blood flow restricted exercise. Eur J Appl Physiol. 2012;112(8):2903-2912. doi:10.1007/s00421-011-2266-8
- US International Trade Commission. Certain blood flow restriction devices with rotatable windlasses and components thereof; institution of a formal enforcement proceeding (Inv. No. 337-TA-1364). Fed Regist. 2025;90(54):13390-13391. Accessed November 14, 2026. https://www.govinfo.gov/content/pkg/FR-2025-03-21/html/2025-04822.htm
This article is intended for educational purposes for trained EMS professionals and does not replace local protocols, medical direction, or formal clinical training. Always practice within your scope and your service's current clinical guidelines.
