Masimo 2918 LNCS E1 Adult Single-Patient-Use Ear Sensor, 3 ft, 10/Box
Need a reusable ear clip sensor? See the RD SET TC-I ear clip (4053).
The 2918 is the LNCS version of the Masimo E1; the M-LNCS version is the 2919 and the RD SET version is the 4015. For a reusable ear clip on an LNC or Red LNC cable, see the 1895 TC-I.19
Works With:
| Patient Cable | Red LNC cable (20-pin port): 2055 Red LNC-04, 4 ft, 2056 Red LNC-10, 10 ft.3 LNC cable (14-pin port): 2017 LNC-4, 4 ft, 1814 LNC-10, 10 ft.2 More: Masimo LNCS patient cables. |
|---|---|
| Monitors |
Zoll X Series, X Series Advanced, Propaq: Zoll 8000-000456.8 LIFEPAK 15: Stryker's selection guide lists 11171-0000674 and its store files it under LIFEPAK 15 and LIFEPAK 20e,7 though its LIFEPAK 15 and 20e accessories guides do not.56 Other devices: Masimo SET MS-2000 (version 4.8 or higher) or rainbow SET MX.1 |
| Stryker / Physio-Control Number | 11171-000067 (LNCS E1, adult; Stryker's store descriptor reads REF 2918)47 |
| Zoll Number | 8000-000456 (LNCS E1, single patient ear sensor, box of 10)8 |
| Cross-Reference | See the Masimo 2918 row in the Masimo Part Number Cross-Reference |
Product Highlights:
- Ear concha placement: The emitter limb rests in the hollow of the inner ear, the detector limb lies flat behind the ear, and the notch fits under the smallest part of the lobe. It is not for any other site.1
- Monitor requirement: Runs only on Masimo SET MS-2000 (version 4.8 or higher) or rainbow SET MX monitors; an LNC cable alone is not enough. Validated on the Radical-7, Rad-8, Rad-5, Rad-87 and Rad-57.1
- Accuracy: SpO2 2.5% Arms and pulse rate 3 bpm with Masimo SET, at no motion and in low perfusion.1
- Single patient use: Discard it after one patient. It is not for prolonged use at one site; for extended monitoring move it to the opposite ear.1
- Contraindications: Foam rubber or adhesive tape allergy, a pierced ear, and redness, swelling, infection or broken skin at the site, including behind the ear.1
Specifications:
| Masimo Part Number | 2918 |
|---|---|
| SKU | MAS-2918 |
| Product Family | LNCS E1 (Masimo SET) |
| Sensor Type | Single-patient-use ear sensor, inner ear (cavum conchae)110 |
| Parameters | SpO2 and pulse rate1 |
| Patient Weight | Adult and pediatric, over 30 kg1 |
| Cable Length | 3 ft11 |
| Connector | LNCS (9-pin DB9), for LNC and Red LNC patient cables9 |
| Use | Single patient use; discard after use1 |
| Pack Quantity | Box of 10 sensors1011 |
| Natural Rubber Latex | Not made with natural rubber latex110 |
| Sterility | Non-sterile1 |
| GTIN | 1084399700496810 |
| Directions for Use | Masimo LAB-6041L1 |
Who Uses This:
- Fire Departments: Crews take an ear reading at rehab or on scene when digit access is not possible, with no sensor to clean afterward.112
- EMS Agencies: Crews use it as the single-patient ear option when digit access is not possible, discarding the sensor after use.112
- Flight and Critical Care Transport: Transport teams use the E1 as an ear site on an LNC or Red LNC cable when neck stabilization or a forehead brain function or cerebral oximetry sensor rules out the forehead.12
- Clinics and Urgent Care: On monitors that meet the E1's software requirement, exam-room and urgent care staff check patients with finger deformities or limited digit access at the ear.112
Related Products:
- Masimo 2055 Red LNC-04 SpO2 Patient Cable, 20-Pin, 4 ft
- Masimo 2017 LNC-4 SpO2 Patient Cable, 14-Pin, 4 ft
- Masimo 1895 LNCS TC-I Adult Reusable Ear Clip SpO2 Sensor, 3 ft
- Masimo 2919 M-LNCS E1 Adult Single-Patient-Use Ear Sensor, 10/Box
- Masimo 4015 RD SET E1 Adult Single-Patient-Use Ear Sensor, 10/Box
- Masimo LNCS Sensors
Frequently Asked Questions:
Which monitors work with the Masimo 2918 LNCS E1, and what software does it need?
The monitor must contain Masimo SET MS-2000 (version 4.8 or higher) or rainbow SET MX technology; an LNC cable alone is not enough.19 Masimo validated the E1 on the Radical-7, Rad-8, Rad-5, Rad-87 and Rad-57.1 Zoll lists the 2918 for the X Series, X Series Advanced and Propaq.8 For a LIFEPAK 15, send us the monitor and cable model and we confirm the fit.
Does any LNC cable work with the Masimo 2918, or does it need something special?
No special cable. The 2918 uses the same LNC and Red LNC cables as other LNCS sensors, chosen by the monitor port: the Red LNC-04 (2055) or Red LNC-10 (2056) on a 20-pin port, the LNC-4 (2017) or LNC-10 (1814) on a 14-pin port.23 The cable is not the limit: on a monitor without the required board the E1 may give no reading.1 M-LNC, rainbow RC and RD cables do not take it.9
What are the Stryker/Physio-Control and Zoll numbers for the Masimo 2918?
11171-000067 is the Stryker/Physio-Control number, and Stryker's store descriptor for it reads REF 2918.47 8000-000456 is the Zoll number, listed as the single patient ear sensor, LNCS E1, box of 10.8 Do not confuse 11171-000067 with Stryker's M-LNCS E1, 11171-000066, which is the 2919.
Pick the 2918, 2919 or 4015 E1: which Masimo E1 matches my monitor cable?
Match the cable. An LNC or Red LNC cable takes the 2918. An M-LNC or rainbow RC cable takes the 2919, Stryker 11171-000066. An RD or RD rainbow SET cable takes the 4015, Stryker 11996-000507.9 All three are single-patient-use ear sensors for patients over 30 kg.1
Is the Masimo 2918 an ear clip or an adhesive sensor, and how do I place it?
Neither: the ear holds it. Pull the emitter and detector limbs apart, set the emitter limb (star forward) in the hollow of the inner ear, lay the detector pad flat behind the ear, and fit the notch under the smallest part of the lobe. Stick the cable's anchor tab to the anchor pad on the shoulder skin, not clothing, and do not tape the sensor.1
Can the Masimo 2918 go on a pierced ear or a small ear?
Not over a piercing. It also cannot go on skin that is red, swollen, infected or broken, or on a patient allergic to foam rubber or adhesive tape.1 If the inner ear cannot hold the emitter limb without touching the tragus or crus of helix, use a digit sensor instead, such as the 1863 DCI.1
Is the Masimo 2918 reusable, and how long can it stay on one ear?
No. It is single patient use: it stays with one patient and is discarded. It is not for prolonged use at one site and carries no fixed hour limit; move it to the opposite ear for extended monitoring, or use a Masimo adhesive digit sensor if it cannot be moved. Check the site frequently, as often as every hour on poorly perfused patients.1
Is this a genuine Masimo 2918?
Yes. We are an authorized Masimo distributor. Every Masimo 2918 ships new in its original Masimo packaging.
How fast does the Masimo 2918 ship?
Most orders ship within 1 to 2 business days. Expedited and overnight shipping are available at checkout.
How do I order the Masimo 2918 or request a quote?
Add it to your cart on this page, or contact CustomerService@pacificbiomedical.com or 844.436.3526 with SKU MAS-2918. We support net terms for agencies and hospitals and ship to all 50 states.
References
- Masimo. Directions for Use, E1 Series ear sensors, LNCS/M-LNCS single patient use. LAB-6041L. techdocs.masimo.com.
- Masimo. Directions for Use, LNC patient cables. LAB-3490L. techdocs.masimo.com.
- Masimo. Directions for Use, Red patient cables (Red LNC and Red PC). LAB-3569P. techdocs.masimo.com.
- Stryker. Masimo sensor selection guide for SpO2 and rainbow (SpO2, SpCO, SpMet), for use with LIFEPAK 15 monitor/defibrillators. GDR 3308460_H, 2019. stryker.com.
- Stryker. LIFEPAK 15 accessories guide, pulse oximetry accessories (02/2025), page 8. stryker.com.
- Stryker. LIFEPAK 20e genuine accessories, GDR 3300292_K. stryker.com.
- Stryker. Online store listing, Masimo LNCS E1 Ear Sensor (LNCS E1, ADULT, EAR SENSOR, REF 2918), catalog 11171-000067, filed under LIFEPAK 15 and LIFEPAK 20e equipment, reviewed October 2026.
- Zoll. Zoll web store, Masimo Single Patient Ear Sensor, LNCS E1, Box of 10, item 8000-000456 (Propaq, X Series, X Series Advanced); Red LNC-4 and Red LNC-10 cables, items 8000-0330 and 8000-0331. Reviewed October 2026.
- Masimo. SET and rainbow Sensor and Cable Compatibility, with minimum software requirements. PLM-10747D, 2023. masimo.fr.
- U.S. Food and Drug Administration. Global Unique Device Identification Database (GUDID), box identifier 10843997004968, MasimoSET LNCS E1 SpO2 Adult Pulse Oximeter Adhesive Sensor, model 2918, device count 10. accessgudid.nlm.nih.gov.
- Masimo. LNCS single-patient-use sensors, product table: LNCS E1 Adult SpO2 Ear Sensor, 3 ft, over 30 kg (masimo.co.uk). masimo.co.uk.
- Masimo. E1 Ear Sensor, single-patient-use sensor designed for the ear concha, product information. PLM-11747C, 2019. masimo.fr.
| Item # | Image | Price | Quantity |
|---|---|---|---|
|
Masimo 2918 LNCS E1 Adult Single-Patient-Use Ear Sensor, 3 ft, 10/Box MAS-2918 |
|
$244.00 10-bx
|
Authorized Masimo Distributor Genuine Masimo Product Most items ship in 1 to 2 business days |
| Item # | Image | Description | Quantity |
|---|