Masimo 3737 Rad-57 Kit with SpMet, Adult and Pediatric Sensors

This item requires a clinical attestation, confirmed in your cart.

SKU: MAS-3737
The Masimo 3737 Rad-57 Kit with SpMet is a handheld Pulse CO-Oximeter kit for adult and pediatric patients that measures SpO2, pulse rate, perfusion index and methemoglobin (SpMet), and it does not read carboxyhemoglobin (SpCO).12 It contains the Rad-57 with the SpMet option, an adult and a pediatric rainbow sensor that share one RC-01 patient cable, and a red carry case.1 The 3737 is a genuine Masimo device for methemoglobin readings on adult and pediatric patients.

Choose the 3737 for methemoglobin, not carbon monoxide: only the 3734, 3735 and 3736 carry the SpCO option. The 9216-U is the SpO2-only Rad-57, and the 3737 and 3735 are the two kits with a pediatric sensor.1

Works With:

In the Box Rad-57, SpMet option, adult and pediatric rainbow sensors, RC-01 cable, red carry case.1
The kit line prints no part numbers; Masimo's Rad-57 page shows the rainbow DCI (2696) and DCI-P (2697) sensors and the RC cables (2405, 2406) beside the kit table. The red carry case has no published part number: the manual lists the 2208 as black and the 2209 as red.12
Sensors SpMet reads on the rainbow DCI (adult, over 30 kg) and DCI-P (pediatric, 10 to 50 kg), on the adhesives 2221, 2219, 2222 and 2220, and on direct-connect rainbow sensors.2
LNCS sensors give SpO2 only.2
Patient Cable Rainbow RC cables: RC-1 (2405), RC-4 (2406), RC-4 EMS (4481).34
Direct-connect rainbow sensors plug into the Rad-57 with no cable.2
Accessories SpCO option (2296): ask us whether your unit accepts it.2
Rad-57 EMS carrying case (2208); data transfer download cable (2063), whose 72-hour trend memory records only while Trend is set to ON (factory default Off).52
Not For Carbon monoxide screening: no SpCO option in this kit; see the 3734, 3735 or 3736.1

Product Highlights:

  • No carbon monoxide reading: The kit has the SpMet option only, so it reads methemoglobin, not carboxyhemoglobin; CO exposure can sit behind a normal SpO2.6
  • Accuracy: SpMet is rated 1% over 1 to 15% (ARMS), from testing on healthy adult volunteers, and it was not validated under motion or low perfusion.56
  • Two sensors, one cable: An adult sensor for patients over 30 kg and a pediatric sensor for 10 to 50 kg share the RC-01 cable.16
  • Alarm default: SpMet high alarm 3% and low alarm off, adjustable, kept after a power cycle.2
  • Screen, not diagnosis: SpMet does not replace laboratory blood testing; confirm suspected methemoglobinemia with laboratory CO-oximetry.56

Specifications:

Masimo Part Number 3737
SKU MAS-3737
Product Family Rad-57 Pulse CO-Oximeter7
Device Type Handheld Pulse CO-Oximeter kit1
Parameters SpO2, pulse rate, perfusion index, SpMet12
Patient Weight Adult sensor over 30 kg; pediatric sensor 10 to 50 kg6
Battery 4 AA alkaline (none named in the kit line); up to 10 hours at lowest indicator brightness51
Display LED5
Dimensions 6.9 x 3 x 1.4 in (17.5 x 7.6 x 3.6 cm)5
Weight 13 oz with batteries5
GTIN 00843997010429
Directions for Use Masimo LAB-9204A (Rad-57 Operator's Manual)2

Who Uses This:

  • Fire Departments: Fire-based EMS units that want SpMet on adults and children use the 3737; carbon monoxide checks in rehab need the 3734 or 3735.1
  • EMS Agencies: Crews add an SpMet reading for a stable adult or pediatric patient whose pulse oximeter SpO2 does not fit the clinical picture, because methemoglobin alters SpO2.28
  • Flight and Critical Care Transport: Transport teams follow SpMet on adults and children with the kit's two sensors, within the Rad-57's -1,000 to 18,000 ft operating range.2
  • Clinics, Urgent Care and Dental Offices: Dental offices and clinics that apply benzocaine or prilocaine can read SpMet on adults and children; a published summary of 242 local-anesthetic episodes ties methemoglobinemia to both.8

Related Products:

Frequently Asked Questions:

Does the Masimo 3737 read carbon monoxide?

No. The 3737 has the SpMet option only, so its rainbow sensors read SpO2, pulse rate, perfusion index and SpMet, not SpCO.12 For carbon monoxide choose the 3734, 3735 or 3736, or add the SpCO option (2296) if your unit accepts it.

Which kit do I need for methemoglobin: the 3737 or the 3736?

The 3737 when SpMet is the added parameter and children are among your patients: it has adult and pediatric sensors but no SpCO. The 3736 reads SpMet and SpCO with an adult sensor only, and the 3735 has SpCO and both sensors but no SpMet.1

Which sensors read SpMet on the Masimo 3737?

The rainbow reusables (DCI over 30 kg, DCI-P 10 to 50 kg), the rainbow adhesives R25, R25-L, R20 and R20-L, and the direct-connect rainbow sensors all report SpMet on the Rad-57.2 Direct-connect sensors plug in with no cable and give SpMet without SpCO. LNCS sensors give SpO2 only.2

Can I follow SpMet with the Masimo 3737 during methylene blue treatment?

Not reliably. Intravascular dyes such as methylene blue and indocyanine green can make SpO2, SpCO and SpMet readings inaccurate on the Rad-57.26 When elevated methemoglobin is suspected, send a blood sample for laboratory CO-oximetry.6

Can the Masimo 3737 check SpMet on an infant or neonate?

The Rad-57's SpMet accuracy (1% over 1 to 15%) is specified for adults, pediatrics, infants and neonates.5 The kit's reusable sensors are for patients over 10 kg (adult over 30 kg, pediatric 10 to 50 kg), so smaller patients need a rainbow adhesive such as the 2220 on the RC cable.62

How do I take an SpMet reading with the Masimo 3737?

Connect the sensor to the RC-01 cable and the cable to the Rad-57, apply the sensor and press the power button. Dashes show until the readings settle: under 20 seconds for SpO2 and up to 120 seconds for SpMet.2 SpMet shows continuously once the sensor is placed and calibration finishes.2

Can I add SpCO to the Masimo 3737 later?

Possibly. SpCO is a parameter option for the Rad-57, installed with Masimo's Field Upgrader Tool.52 Send us the model and serial number and we will confirm the unit accepts it before you order the 2296. SpCO also needs an SpCO-rated rainbow sensor; the reusable DCI and DCI-P are.2

Which patient cable does the 3737 use?

The kit includes one RC-01 patient cable for its adult and pediatric rainbow sensors.1 Rainbow RC cables: RC-1 (2405), RC-4 (2406) and RC-4 EMS (4481). Direct-connect rainbow sensors plug in with no cable.342 See the part number cross-reference for sensors and patient cables.

Is this a genuine Masimo 3737?

Yes. We are an authorized Masimo distributor. Every Masimo 3737 ships new in its original Masimo packaging.

How fast does the Masimo 3737 ship?

Most orders ship within 1 to 2 business days. Expedited and overnight shipping are available at checkout.

How do I order the Masimo 3737 or request a quote?

Add it to your cart on this page, or contact CustomerService@pacificbiomedical.com or 844.436.3526 with SKU MAS-3737. We support net terms for agencies and hospitals and ship to all 50 states.

References
  1. Masimo. Rad-57 Pulse CO-Oximeter product page: options, accessories and kit lines (masimo.co.uk), reviewed October 2026. masimo.co.uk.
  2. Masimo. Rad-57 Signal Extraction Pulse CO-Oximeter Operator's Manual. LAB-9204A, 2016. techdocs.masimo.com.
  3. Masimo. Directions for Use, rainbow Series patient cables. LAB-4523J. techdocs.masimo.com.
  4. Masimo. Directions for Use, rainbow Series patient cables, EMS. LAB-9877B. techdocs.masimo.com.
  5. Masimo. Rad-57 Pulse CO-Oximeter product information, specifications and compatible accessories. PLM-10151C, 2022. masimo.com.
  6. Masimo. Directions for Use, rainbow DC Series reusable SpCO, SpMet and SpO2 sensors (rainbow DCI and DCI-P). LAB-4869K. techdocs.masimo.com.
  7. U.S. Food and Drug Administration. Global Unique Device Identification Database (GUDID), Masimo model 3737, Rad-57 Pulse CO-Oximeter (device identifier 00843997010429). accessgudid.nlm.nih.gov.
  8. Guay J. Methemoglobinemia related to local anesthetics: a summary of 242 episodes. Anesth Analg. 2009;108(3):837-845. pubmed.ncbi.nlm.nih.gov.
Item # Image Price Quantity

Masimo 3737 Rad-57 Kit with SpMet, Adult and Pediatric Sensors

MAS-3737

$4,699.50

ea

Authorized Masimo Distributor Genuine Masimo Product

Most items ship in 1 to 2 business days

Authorized Masimo Distributor
Genuine Masimo Product
Most items ship in 1 to 2 business days
Item # Image Description Quantity