NomoLine LH Adult Nasal CO2 Cannula with O2, 25/box

SKU: MAS-3820

The Masimo NomoLine LH Adult Nasal CO2 Cannula with O2 (Mas-3820, 25 per box) Delivers supplemental oxygen to an adult patient and, at the same time, draws a continuous sidestream sample so your monitor can display an end-tidal CO2 number and waveform. It is a single-patient-use cannula on a 2 meter line that connects directly to a Masimo ISA gas analyzer, utilizing a hydrophobic bacterial filter keeps water and contamination out of the analyzer.1 

Item NumberMAS-3824
Pack25 per box
Line Length2 meters
PatientAdult, non-intubated
Sample Flow50 sml/min nominal
Water TrapNone required

Product Highlights

  • Oxygen and capnography through one cannula. The patient gets supplemental O2 and you get a continuous CO2 waveform without a second interface competing for the same face. That matters because supplemental oxygen is exactly the condition under which pulse oximetry stops being an early warning.
  • No water trap to empty, drain, or forget. NomoLine wicks condensed moisture into a hydrophilic absorbent and lets it evaporate out through the polymer cover, so the gas sample stays dry without a collection chamber. A hydrophobic bacterial filter protects the analyzer from water intrusion and contamination.1
  • Low sampling flow, 50 sml/min. The ISA analyzer draws only 50 sml/min through this line, which is what lets it read accurately on patients with small tidal volumes and fast respiratory rates.3 Masimo specifies accurate measurement from 0 to 150 breaths per minute at that sampling rate.7
  • Fast enough to trust the waveform. CO2 rise time at 50 sml/min is 200 milliseconds or less, and total analyzer system response time is under 3 seconds.3 Masimo states that under 3 second figure specifically with a 2 meter sampling line, which is exactly this part.7
  • LH means short-term, low-humidity use. Masimo's directions for use define LH as designed for short term applications with low humidity, where the line collects water, and HH as engineered to remove aspirated and condensed water for long term, high-humidity applications.2 That is a duty-cycle distinction, not a room-climate one, and almost nobody publishes it correctly.
  • Split-flow cannula with star-shaped O2 tubing. The split-flow design reduces mixing between the delivered oxygen and the sampled gas, and the star-shaped lumen on the oxygen tubing resists kinking.
  • Connects straight to the ISA analyzer. Part 3820 is in Masimo's direct-connection group, so no Luer adapter and no multi-patient adapter is needed between the cannula and the analyzer.2
  • Single patient use, not made with natural rubber latex, and not to be sterilized by any method, per the Masimo directions for use.2
  • 25 per box from Pacific Biomedical at $11.88 per cannula, which is 44 percent below the next national EMS distributor we priced for the same Masimo part number.

Why Sample CO2 Through the Same Cannula That Delivers the Oxygen

 A patient on oxygen can stop ventilating adequately and hold an acceptable SpO2 for some time, which means the oximeter reports normal while the problem is already underway. Capnography measures ventilation directly, breath by breath, and that is the argument for a cannula that carries both.

In a randomized controlled trial of 163 children undergoing 174 procedures under moderate sedation, all of whom received 2 L of supplemental oxygen by nasal cannula, blinded capnography indicated alveolar hypoventilation during 56 percent of procedures and apnea during 24 percent, while clinical staff relying on routine monitoring documented poor ventilation in only 3 percent and no apnea at all. Patients in the arm where capnography findings prompted intervention were significantly less likely to desaturate.4 In a separate controlled comparison during sedated colonoscopy, 29 episodes of apnea or hypoventilation occurred in 16 of 50 patients, and pulse oximetry detected only 38 percent of them, with a mean delay of 38.6 seconds on the episodes it did catch. The authors note that this delay is worse when supplemental oxygen is provided.5

Use the device according to the Masimo directions for use2 and your agency's protocols and medical direction.

Specifications and Compatibility

Specification Detail
Manufacturer Masimo Corporation
Item Number 3824
Pacific Biomedical SKU MAS-3824
Product NomoLine LH Adult Nasal CO2 Cannula with O2 Delivery
Humidity Class LH (low humidity). Designed for short term applications; the line collects water. HH lines are the long-term, high-humidity option.2
Patient Population Adult, non-intubated, spontaneously breathing
Sampling Line Length 2 meters (approximately 6.5 feet)1
Oxygen Delivery Integrated. Star-shaped lumen oxygen tubing; connect the supply tubing to the oxygen source and set the flow per your protocol.2
Sampling Flow Rate 50 plus or minus 10 sml/min at the ISA analyzer3
CO2 Rise Time 200 ms or less at 50 sml/min sample flow3
System Response Time Under 3 seconds, specified with a 2 meter sampling line7
Respiratory Rate Range Accurate from 0 to 150 breaths per minute at a 50 mL/min sampling rate7
Moisture Handling No water trap. Hydrophilic absorbent plus a Nomo polymer cover that evaporates water into the surrounding air, with a hydrophobic bacterial filter protecting the analyzer.1
Connection Direct connection to the ISA analyzer. No Luer adapter and no multi-patient adapter required.2
Reuse Single patient use.2 Do not attempt to sterilize by autoclave, irradiation, steam, gas, ethylene oxide, or any other method.2
Latex Not made with natural rubber latex2
Regulatory Status Prescription device. See the Regulatory and Shipping section below.
Pack Size 25 per box
Related Part Numbers 3817 adult nasal without O2; 3821 pediatric nasal with O2; 4624 adult nasal with O2 on a 4 meter line; 3824 adult nasal/oral with O2; 3814 adult/pediatric airway adapter set for intubated patients1
Maximum Use Time Masimo's directions for use describe the NomoLine sampling lines as single patient use products with a maximum of 14 days of use. Follow the directions for use and your agency's policy. Contact us if you need a written duration statement from Masimo for a bid or an infection control file.

Complete the Monitoring Setup

This cannula covers the spontaneously breathing adult on a Masimo ISA analyzer. Here is what Pacific Biomedical carries around it.

What's Included

  • 25 Masimo NomoLine LH Adult Nasal CO2 Cannulas with O2 delivery (item 3820)
  • Each cannula is a single-patient-use nasal interface on an integrated 2 meter sampling line with a hydrophobic bacterial filter and a direct ISA connector
  • Integrated oxygen supply tubing with a star-shaped lumen
  • No water trap, adapter, or separate filter to buy; nothing else is required between the cannula and a Masimo ISA analyzer
  • Pediatric (3821), 4 meter (4624), nasal/oral (3824), and intubated airway adapter (3814) configurations are made by Masimo. 

Who Uses This

Ground EMS & Ambulance

Altered mental status, overdose, respiratory distress, and post-sedation transports where the patient is on oxygen and breathing on their own, and the crew needs ventilation data, not just a saturation number.

Critical Care & Interfacility Transport

Long moves on a Masimo ISA-equipped monitor where nobody wants to be draining a water trap in the back of a truck or replacing a fouled sampling line mid-transport.

Emergency Department & Procedural Sedation

Non-intubated patients under moderate sedation on supplemental oxygen, the exact population where capnography catches what oximetry reports late.

Biomed & Materials Management

Standardizing the consumable that feeds the Masimo ISA analyzers already in the fleet, on a part number with a published flow rate, response time, and directions for use.

Frequently Asked Questions
What is an EtCO2 nasal cannula, and what is capnography on a nasal cannula used for?
An EtCO2 nasal cannula is a nasal interface that samples exhaled gas and pipes it to a capnography analyzer, giving you an end-tidal CO2 number and waveform on a patient who is breathing on their own rather than through a tube. This one also delivers oxygen through the same device. It is used to watch ventilation continuously in non-intubated patients: sedation, altered mental status, overdose, and respiratory distress.
Does supplemental oxygen through the cannula change the EtCO2 reading, and what flow rate should I use?
The split-flow design separates delivered oxygen from sampled gas to limit dilution, and the analyzer pulls a low 50 sml/min sample.3 Set the oxygen litre flow per your protocol; this is a standard low-flow nasal cannula, not a high-flow device, so it cannot deliver 100 percent oxygen. Note the two different flow numbers people mean by this question: the oxygen you set, and the fixed 50 sml/min the analyzer draws.
What is the difference between NomoLine LH and HH sampling lines?
Masimo's directions for use define LH as designed for short term applications with low humidity, where the line collects water, and HH as engineered to remove aspirated and condensed water for long term, high-humidity applications.2 It describes the duty cycle and the gas being sampled, not the temperature of the room you are working in. Item 3820 is an LH line. Neither type needs a water trap.
What can cause an inaccurate capnography reading with a sampling line?
Common causes are a kinked, occluded, or wet sampling line, a loose connection leaking room air into the sample, mouth breathing that bypasses a nasal-only cannula, and a line used past its intended duration. The NomoLine design addresses the moisture path specifically by wicking water out through the polymer and filtering the sample before it reaches the analyzer.1 If your patient is a mouth breather, the nasal/oral configuration 3824 is the right part.
Which monitors does this NomoLine work with, and will it fit a ZOLL Zenix?
Yes, it is compatible with the Zoll Zenix. It connects directly to Masimo ISA gas analyzers, including the host platforms Masimo lists for NomoLine: Rad-97, Root, Radical-7, and MOC-9 measurement modules.1 For the Zenix, go by ZOLL's own EMS operator's guide, which instructs users to "use only Masimo CO2 sampling lines" and refers to NomoLine by name.6 
Is it single use, and can it be cleaned or sterilized?
Single patient use. Masimo's directions for use classify the NomoLine sampling lines as single patient use products and instruct that they not be sterilized by autoclave, irradiation, steam, gas, ethylene oxide, or any other method.2 The same document describes a maximum of 14 days of use. It is not made with natural rubber latex. Follow the directions for use and your agency's policy on single-use consumables.
Is this a prescription device, and how many come in a box?
Yes, it is a prescription device. Both the NomoLine directions for use and the NomoLine ISA operator's manual carry the federal legend restricting sale to or on the order of a physician.2,3 The exact wording is in the Regulatory section below. Item 3820 is sold 25 cannulas per box. Contact us if your account is not yet set up for prescription items and we will walk you through it.
Is this an authentic Masimo product?
Yes. Pacific Biomedical supplies genuine, factory-fresh Masimo Corporation products sourced through authorized channels, shipped in original manufacturer packaging.
How fast does this ship?
In-stock orders typically ship within one business day. For expedited shipping, current lead times, or bulk orders, contact us at CustomerService@pacificbiomedical.com or 844.436.3526.
How do I place an order, request a quote, or set up an account?
Add the item to your cart to order online, or contact us for volume pricing, GPO or contract pricing, agency purchase orders, and net terms. Reach us at CustomerService@pacificbiomedical.com or 844.436.3526.
References
  1. Masimo Corporation. NomoLine cannulas and airway adapter sets. Accessed August 21, 2026. https://www.masimo.com/products/sensors/nomoline/airway-adapters/
  2. Masimo Corporation. NomoLine airway adapter sets and cannulas: directions for use. LAB-9841A-eIFU. Accessed August 21, 2026. https://techdocs.masimo.com/globalassets/techdocs/pdf/lab-9841a-eifu.pdf
  3. Masimo Corporation. NomoLine ISA CO2 sidestream gas analyzer operator's manual. LAB-10152A. Accessed August 21, 2026. https://techdocs.masimo.com/globalassets/techdocs/pdf/lab-10152a_master.pdf
  4. Lightdale JR, Goldmann DA, Feldman HA, Newburg AR, DiNardo JA, Fox VL. Microstream capnography improves patient monitoring during moderate sedation: a randomized, controlled trial. Pediatrics. 2006;117(6):e1170-e1178. doi:10.1542/peds.2005-1709
  5. Cacho G, Perez-Calle JL, Barbado A, Lledo JL, Ojea R, Fernandez-Rodriguez CM. Capnography is superior to pulse oximetry for the detection of respiratory depression during colonoscopy. Rev Esp Enferm Dig. 2010;102(2):86-89. doi:10.4321/s1130-01082010000200003
  6. ZOLL Medical Corporation. Zenix EMS operator's guide. 9650-000421-06. Accessed August 21, 2026. https://www.zoll.com/-/media/product-materials/product-manuals/zenix/06/9650-000421-06-sf_b.ashx
  7. Masimo Corporation. Masimo capnography and multi-gas monitoring. Whitepaper PLM-14382A. Accessed August 21, 2026. https://www.masimo.com/siteassets/us/documents/pdf/plm-14382a-whitepaper-masimo-infrared-spectrometry-global.pdf

Peer-reviewed citations located via PubMed. This information supports product education and does not replace your agency's protocols, medical direction, or the manufacturer's Instructions for Use.

Authorized Masimo Distributor (USA). Genuine, factory-fresh product in original manufacturer packaging.

This legend appears in both the NomoLine directions for use and the NomoLine ISA CO2 operator's manual.2,3

Single patient use. Not made with natural rubber latex. Do not attempt to sterilize by autoclave, irradiation, steam, gas, ethylene oxide, or any other method.2 Use the device according to the manufacturer's Instructions for Use and your agency's protocols and medical direction.

In-stock orders typically ship within one business day. For current lead times, expedited options, or bulk orders, contact us at CustomerService@pacificbiomedical.com or 844.436.3526.

Order the Masimo NomoLine LH Adult Nasal CO2 Cannula with O2, 25/box

Genuine Masimo Corporation product, item 3820. Volume, GPO, and agency pricing available.

844.436.3526

CustomerService@pacificbiomedical.com

Item # Image Price Quantity

NomoLine LH Adult Nasal CO2 Cannula with O2, 25/box

MAS-3820

Masimo NomoLine LH Adult Nasal CO2 Cannula with O2 PN 3820 — adult nasal cannula with teal oxygen tubing and clear CO2 sampling line on white background

$297.00

25-bx

Item # Image Description Quantity