SAM Pelvic Sling II, Small, 27-45 in, PS300-OB-EN

Rx Item: Approval Needed Before Checkout

Available to healthcare organizations, licensed prescribers and buyers with a signed medical director authorization form.

How to Qualify
  • Agency or facility: sign up with your work email. It's the fastest way to be verified.
  • Licensed prescriber: add your 10-digit NPI number or upload your license.
  • Working under a medical director: we email them our authorization form to sign online, or you can upload a signed copy.

We review accounts within 1 business day.

You can add it to your cart now and check out once you're approved.

Create Your Account

Already have an account? Sign In

SKU: SM-PS300-OB-EN

The SAM Medical PS300-OB-EN is the SAM Pelvic Sling II, Small, for hip circumferences of 27 to 45 in (69 to 114 cm): a non-invasive circumferential pelvic belt that stabilizes pelvic fractures during transport, with an AUTOSTOP buckle that clicks when the target force is reached.12 We supply it with the other pelvic binders.

Product Highlights:

  • Size: Small, hip circumference 27 to 45 in (69 to 114 cm).1
  • AUTOSTOP buckle: two prongs click out at 150 N of circumferential pressure, guarding against over- or under-tightening.2
  • Imaging: radiolucent except the buckle's two stainless steel springs; MR Conditional at 3 tesla or less.21
  • Tapered front: allows urinary catheterization, interventional radiology, external fixation and abdominal surgery without removal.2
  • Low-friction posterior slider: eases patient transfers.2
  • Single use: dispose of per facility biohazard protocol.13

What Is in the Box:

  • 1 SAM Pelvic Sling II, Small, part PS300-OB-EN.13

Specifications:

Manufacturer SAM Medical Products
Brand SAM Pelvic Sling II
Part number PS300-OB-EN1
GUDID device identifier 008220454286213
Size Small1
Hip circumference 27 to 45 in (69 to 114 cm)1
Operating principle Target force at 150 N circumferential pressure2
Color Orange/blue (civilian)2
Packaged size 5.5 x 7.5 x 3.75 in (14 x 19 x 9.5 cm)2
Packaged weight 8.6 to 9.2 oz (244 to 250 g), varies by size2
MRI MR Conditional, 3 T or less1
Single use Yes13
GMDN term Pelvic fracture binder, single-use3
Pack 1 sling

Sizes and Part Numbers:

The Standard size fits 95% of the population; Small and Large cover most other body types.2

Small, PS300-OB-EN Hip circumference 27 to 45 in (69 to 114 cm)1
Standard, PS301-OB-EN Hip circumference 32 to 50 in (81 to 127 cm)1
Standard military, PS301-OD-EN Hip circumference 32 to 50 in (81 to 127 cm), OD green/black1
Large, PS302-OB-EN Hip circumference 36 to 54 in (91 to 137 cm)1

Related Products:

Product Guides and Documents:

Frequently Asked Questions:

What does the PS300-OB-EN SAM Pelvic Sling treat?

It reduces and stabilizes unstable pelvic injuries in the field. It is indicated for patients who have, or are suspected of having, a pelvic ring fracture where hemorrhage might occur.51

Is the PS300-OB-EN pelvic sling the same as a pelvic binder?

Both names describe a circumferential pelvic belt. The SAM Pelvic Sling II is a non-invasive circumferential pelvic belt, and FDA GUDID classifies it under the GMDN term "Pelvic fracture binder, single-use".13

What size SAM Pelvic Sling do I need on PS300-OB-EN?

Measure hip circumference: Small fits 27 to 45 in, Standard 32 to 50 in and Large 36 to 54 in. The Standard size fits 95% of the population.12

How do you apply the SAM Pelvic Sling II on PS300-OB-EN?

Empty the pockets and pelvic area, place the sling black side up under the patient at the level of the trochanters, pass the black strap through the buckle, then pull it against the orange strap until the buckle clicks and press the black strap down to secure.1

When is a pelvic binder not recommended on PS300-OB-EN?

Do not use the SAM Pelvic Sling if anatomical landmarks are absent.1

How long can a pelvic binder stay on (PS300-OB-EN)?

The SAM Pelvic Sling II instructions give no fixed wear time; they direct you to monitor the patient's skin for pressure injury while it is in use.1

How does the AUTOSTOP buckle work?

PS300-OB-EN: The target force is reached at 150 N of circumferential pressure, which pushes two prongs from the AUTOSTOP buckle through the Precision Strap with a tactile and audible click.2

Can X-rays, CT or MRI be done with the sling on?

PS300-OB-EN: Yes. All materials are radiolucent except the buckle's two stainless steel springs, and the sling is MR Conditional at 3 tesla or less; keep it firmly attached and do not reposition or remove it in the MR room.21

Is the SAM Pelvic Sling II reusable on PS300-OB-EN?

No. It is a single-use device; reuse may cause infection or reduced performance.1

Can procedures be done without removing the sling?

PS300-OB-EN: Yes. The narrow, tapered front allows urinary catheterization, interventional radiology, external fixation and abdominal surgery without removal.2

Manufacturer Sources
  1. SAM Medical Products. SAM Pelvic Sling II Instructions for Use, PS-IS-EN-4 (issue 2025-12) (accessed 2026-11-07). sammedical.box.com.
  2. SAM Medical Products. SAM Pelvic Sling Product Overview, AFSLI-C-SS-05 (accessed 2026-11-07). sammedical.box.com.
  3. U.S. Food and Drug Administration. AccessGUDID: SAM Medical PS300-OB-EN, SAM Pelvic Sling Small, DI 00822045428621 (accessed 2026-11-07). accessgudid.nlm.nih.gov.
  4. SAM Medical Products. Pelvic Sling by SAM Medical product page (accessed 2026-11-07). sammedical.com.
  5. SAM Medical Products. Fracture Management collection and FAQ (accessed 2026-11-07). sammedical.com.

Specifications are from SAM Medical and FDA GUDID records. Remove objects from the patient's pockets and clothing before application and monitor the skin for pressure injury while the sling is in use.1

Item # Image Price Quantity

SAM Pelvic Sling II, Small, 27-45 in, PS300-OB-EN

SM-PS300-OB-EN

$70.25

ea