Bio-Med Devices Blender PM Kit, 2008B, box of 10

SKU: BMD-2008B

The Bio-Med Devices 2008B is the 10 pack of the Blender PM Kit, part 2008.1 Each kit holds the parts used in the 2-year major overhaul of a Bio-Med Devices air/oxygen blender.2 The 10 pack suits a department servicing several blenders. We supply 2008B by the box.

Product Highlights:

  • 10 pack: Part 2008B is the 10 pack of the Blender PM Kit1
  • Overhaul parts: Filters, O-rings, check valves, diaphragms and spring2
  • 2-year interval: Major overhaul, cleaning and calibration every 2 years21
  • Annual step: Calibration certification every year between PMs2
  • Factory option: Return to the factory is the recommended route for the 2-year service2

What Is in the Box:

  • 10 Blender PM Kits1
  • Each kit: Filters, O-rings, check valve ball, balancing chamber balls, duck bill check valves, bleed muffler and retainer, diaphragms, spring and label. Contents are subject to change without notice.2

Specifications:

Manufacturer Bio-Med Devices, Inc.3
Part number 2008B1
Single kit part number 20083
Pack 10 pack1
PM interval Every 2 years1
Calibration Annual, between PMs1

Size and Compatibility:

The service manual assigns part 2008 to all Bio-Med Devices blenders. The current product listing names it Blender Maintenance Kit, High-Low Flow.23

Related Products:

Product Guides and Documents:

Frequently Asked Questions:

What is in a Bio-Med Devices blender PM kit?

Filters, O-rings, check valve ball, balancing chamber balls, duck bill check valves, bleed muffler and retainer, diaphragms, spring and label. Contents are subject to change without notice.2

How many kits are in 2008B?

10. Part 2008 is the single kit and 2008B is the 10 pack.1

How often does an air/oxygen blender need maintenance?

A performance test before each use, calibration certification every year between PMs, and a major overhaul, cleaning and calibration every 2 years.21

What changes how often a blender needs service?

Frequency and length of use, the quality of the compressed gas sources, and environmental conditions.2

Does a blender need calibration after service?

Yes. Calibration procedures must be performed following servicing of the blender.2

When are the blender inlet filters replaced?

During major overhauls, or whenever they become contaminated. The filter element sits in the air and oxygen supply inlet fittings.2

What does an air/oxygen blender do?

It mixes medical grade air and oxygen to any concentration from 21% to 100% oxygen and delivers the mix to respiratory care devices.2

What is an oxygen blender used for?

Oxygen administration, bubble CPAP therapy and HFNC therapy.4

Which blenders does the PM kit fit?

The service manual assigns part 2008 to all Bio-Med Devices blenders. The current product listing names it Blender Maintenance Kit, High-Low Flow.23

Manufacturer Sources
  1. Bio-Med Devices. Repair Kits, Preventive Maintenance and Calibration Schedules (accessed 2026-11-04). biomeddevices.com.
  2. Bio-Med Devices. Air/Oxygen Blender Service Manual, Catalog #2121, Rev 032709, archived copy of the manufacturer document (accessed 2026-11-04). frankshospitalworkshop.com.
  3. Bio-Med Devices. Product Listing with Part Numbers, REV060326 (accessed 2026-11-04). biomeddevices.com.
  4. Bio-Med Devices. Blender Gallery Product Sheet, DDOC063 Rev031925 (accessed 2026-11-04). biomeddevices.com.

Kit contents are from Bio-Med Devices Service Manual Rev 032709 and are subject to change without notice. Factory installed gas supply fittings must not be substituted with parts not approved by Bio-Med Devices.2

Item # Image Price Quantity

Bio-Med Devices Blender PM Kit, 2008B, box of 10

BMD-2008B

$1,261.56

10-bx
Item # Image Description Quantity