Vyaire LTV Adult Circuit without PEEP, 22 mm, 29657-001, 10/Case
Vyaire LTV Adult Patient Circuit without PEEP, 22 mm, Single Use SPU (MPN 29657-001)
Product Highlights:
- Adult 22 mm circuit: Sized for adult patients over 20 kg (44 lb).3
- Without PEEP: 29657-001 is a patient circuit without PEEP.1 On the LTV 1200 and LTV 1150, PEEP is set with the PEEP control button and Set Value knob, range 0 to 20 cm H2O.4
- Sense lines and drive line: The two exhalation flow transducer sense lines use non-interchangeable Luer fittings, and the exhalation valve drive line connects to the Exh Valve port.4
- 6 ft circuit: 1.8 m x 22 mm inspiratory limb, wye and 61 cm x 22 mm expiratory limb.2
- Single use (SPU): Each circuit is single use and is supplied non-sterile.1
- Case of 10: 10 circuits per case, case GTIN 50190752115932.1
What's Included:
- 10 x Vyaire LTV Patient Circuit without PEEP, 22 mm, single use SPU (29657-001)1
Specifications:
| Brand | LTV1 |
|---|---|
| Manufacturer | Vyaire Medical, Inc.1 |
| Manufacturer part number (MPN) | 29657-0011 |
| Pacific Biomedical SKU | ENV-29657-001 |
| Description | Patient circuit without PEEP, 22 mm, SPU1 |
| Patient size | Adult, over 20 kg (44 lb)3 |
| For use with | LTV Series 1100, 1150 and 1200 ventilators (circuits without PEEP)2 |
| Circuit length | 6 ft2 |
| Inspiratory limb | 1.8 m x 22 mm, with wye2 |
| Expiratory limb | 61 cm x 22 mm2 |
| Earlier catalog number | 10822x10 (22 mm SPU adult circuit without PEEP, LTV 1100, 1150 and 1200)5 |
| Ventilator connection (LTV 1200 / 1150) | 22 mm outlet port, two flow transducer sense lines (Luer), exhalation valve drive line4 |
| Use | Single use (SPU)1 |
| Sterility | Non-sterile1 |
| Pack | 10 per case1 |
| GTIN | Case 50190752115932, unit 101907521159341 |
| FDA premarket submission | 510(k) K101643, Model LTV 1100 Ventilator16 |
| GMDN term | Ventilator breathing circuit, single-use1 |
Use Cases:
- Adult ventilation with an LTV brand 22 mm patient circuit, for patients over 20 kg (44 lb)13
- Stocking a fresh single use circuit for each adult patient1
- Pre-use leak testing of the circuit with the ventilator's Leak Test4
Related products:
- Venti.Plus Adult Test Lung 1.0 L
- Bio-Med Devices Adult Test Lung, PN 1020
- Test lungs for ventilator checks
- All ventilator circuits
Frequently Asked Questions:
How is PEEP set with an LTV circuit without PEEP?
29657-001 is a patient circuit without PEEP.1 On the LTV 1200 and LTV 1150, PEEP is set with the PEEP control button and Set Value knob, range 0 to 20 cm H2O.4
Which LTV circuit is for adults and which is for pediatrics?
The 22 mm patient circuit is the adult circuit, for patients over 20 kg (44 lb).3 The 15 mm patient circuit is the infant and pediatric circuit, for 5 kg to 20 kg (11 lb to 44 lb).3 For other sizes, see all ventilator circuits.
How does the LTV ventilator circuit connect?
On the LTV 1200 and 1150, connect the main breathing tube to the 22 mm outlet port on the right side of the ventilator, the two exhalation flow transducer sense lines to the Flow Xducer ports, and the exhalation valve drive line to the Exh Valve port.4 The sense line fittings are non-interchangeable Luer fittings.4
How do I leak test an LTV circuit?
Attach all circuit accessories, connect the circuit to the ventilator, occlude the proximal end of the circuit with a gloved hand or a 4 x 4 gauze pad, and run the Leak Test from the menu after the 60 second warm up.4 The test fails if flow through the flow valve is greater than 1 L/min.4
Can the proximal sense lines be removed from the wye?
No. Do not remove the proximal sense lines from the patient wye.4 Orient the patient wye so the proximal sense lines point up during operation.4
How long is the LTV 29657-001 circuit, and which LTV ventilators is it for?
It is a 6 ft circuit: a 1.8 m x 22 mm inspiratory limb, wye and 61 cm x 22 mm expiratory limb.2 It is cataloged with the LTV Series 1100, 1150 and 1200 ventilator circuits without PEEP.2
Is 10822 the same circuit as 29657-001?
The 2012 CareFusion catalog listed the 22 mm SPU adult circuit without PEEP for the LTV 1100, 1150 and 1200 as 10822x10, 10 per package, with a 1.8 m x 22 mm inspiratory limb, wye and 61 cm x 22 mm expiratory limb.5 The 2017 catalog lists the same circuit description as 29657-001.2 A version with one water trap and a temp probe port is 29663-001, and the reusable 22 mm circuit without PEEP is 17997-001.2
Is the LTV 29657-001 circuit reusable?
No. It is single use (SPU) and is supplied non-sterile.1
How many circuits come in a case?
10 circuits per case.1
Is part 29657-001 still in commercial distribution?
Yes. 29657-001 is in commercial distribution in the FDA GUDID record.1
Which 510(k) does the FDA GUDID record list for 29657-001?
The record lists premarket submission K101643, product code CBK.1 K101643 is the CareFusion Model LTV 1100 Ventilator clearance, decided January 26, 2011.6
References
- US Food and Drug Administration. Global Unique Device Identification Database (GUDID) record: LTV Patient Circuit W/O PEEP, 22mm, SPU, version or model 29657-001, Vyaire Medical, Inc. (single use, non-sterile, case of 10, GTIN 50190752115932 and 10190752115934, GMDN ventilator breathing circuit single-use, in commercial distribution). Accessed October 30, 2026. accessgudid.nlm.nih.gov.
- CareFusion Corporation. Respiratory ventilation products, portable ventilators, United States catalog. RC8019. 2017:6 (LTV Series 1100, 1150 and 1200 ventilator circuits without PEEP; 29657-001, 6 ft, 1.8 m x 22 mm inspiratory limb, wye and 61 cm x 22 mm expiratory limb, 10 per package).
- CareFusion Corporation. LTV 1200 ventilator emergency set-up card RC2310. 2013 (22 mm patient circuit, adult, over 20 kg and 44 lb; 15 mm patient circuit, infant and pediatric, 5 kg to 20 kg and 11 lb to 44 lb). aarc.org.
- LTV 1200 and 1150 Ventilators Operator's Manual, P/N 19802-001 Rev. F pp. 1-11, 6-22, 11-8, 11-9, C-10 (proximal sense line caution, PEEP control range 0 to 20 cm H2O, Leak Test procedure, patient breathing circuit connection and wye orientation). aarc.org.
- CareFusion Corporation. Respiratory ventilation products, alternate care, United States catalog. RC714. 2012:6 (10822x10 patient circuit without PEEP, 22 mm SPU, LTV Series 1100, 1150 and 1200).
- US Food and Drug Administration. 510(k) premarket notification K101643: Model LTV 1100 Ventilator, CareFusion, decision date January 26, 2011, product code CBK. Accessed October 30, 2026. accessdata.fda.gov.
Follow the LTV ventilator operator's manual and your facility's policy for circuit setup, testing and replacement.
| Item # | Image | Price | Quantity |
|---|---|---|---|
|
Vyaire LTV Adult Circuit without PEEP, 22 mm, 29657-001, 10/Case ENV-29657-001 |
|
$260.00 |
|