Cables and Sensors OxiMax Adapter Cable, Nellcor DEC-4 Compatible
This item requires a clinical attestation, confirmed in your cart.
The Cables and Sensors E704-710 is a 3.5 ft Nellcor OxiMax SpO2 adapter cable compatible with Nellcor DEC-4, 41251 and EC-4.1 It joins sensors that have Nellcor OxiMax technology and 9 pins to the monitor, including LIFEPAK 12 and 15.1 It is a third-party cable, not a Nellcor product. We stock it with the genuine Nellcor OxiMax adhesive sensors.
Product Highlights:
- Replaces Nellcor DEC-4: Also 41251, EC-4, Physio-Control 11110-000042, Welch Allyn 5200-52.1
- OxiMax 9-pin: Male 9-pin D-sub purple to female 9-pin D-sub purple connectors.1
- 3.5 ft reach: Gray 4 mm cable.1
- LIFEPAK 12 and 15: Physio-Control LIFEPAK 12 and 15 are in its fit list.1
- Latex-free: Latex-free and supplied non-sterile.1
What Is in the Box:
- 1 Cables and Sensors E704-710 SpO2 adapter cable, 3.5 ft.1
Specifications:
| Manufacturer | Cables and Sensors1 |
|---|---|
| Part number | E704-7101 |
| Type | SpO2 adapter cable1 |
| Replaces | Nellcor DEC-4, 41251, EC-4; Physio-Control 11110-000042; Welch Allyn 5200-521 |
| SpO2 technology | Nellcor OxiMax1 |
| Monitor connector | Male 9-pin D-sub, purple, dual keyed1 |
| Sensor connector | Female 9-pin D-sub, purple1 |
| Length | 3.5 ft1 |
| Latex-free | Yes1 |
| Sterile | No1 |
| GTIN | 069456648594932 |
| Pack | 1 each |
Related Products:
- Pulse Oximeter Probes collection
- Cables and Sensors DS-100A compatible adult clip sensor
- Cables and Sensors D-YS compatible multisite sensor
- Cables and Sensors MAX-A compatible adult disposable sensor
- Sensoronics DEC-4 compatible OxiMax adapter cable, 4 ft
Frequently Asked Questions:
What does the E704-710 replace (E704-710)?
Nellcor DEC-4, 41251 and EC-4, Physio-Control 11110-000042 and Welch Allyn 5200-52.1
Which sensors does it work with (E704-710)?
Sensors that have Nellcor OxiMax technology and 9 pins.1
Does it fit the LIFEPAK 12 and 15 (E704-710)?
Yes. Physio-Control LIFEPAK 12 and 15 are in its fit list.1
How long is it (E704-710)?
3.5 ft. Cables and Sensors also makes 7 ft (E708-710) and 10 ft (E710-710) lengths.1
Is it a genuine Nellcor DEC-4 (E704-710)?
No. It is a Cables and Sensors cable cross-referenced to DEC-4.1
Why does the monitor show Sensor Off with a new cable or sensor (E704-710)?
That alarm usually means a break in the internal wiring or a bent pin in the connector. Check the pins before you swap parts.3
Is it latex-free (E704-710)?
Yes, latex-free and supplied non-sterile.1
Manufacturer Sources
- Cables and Sensors. Covidien Nellcor Compatible SpO2 Adapter Cable, DEC-4, part number E704-710 (accessed 2026-11-07). cablesandsensors.com.
- U.S. FDA AccessGUDID. Device identifier 06945664859493, model E704-710 (accessed 2026-11-07). accessgudid.nlm.nih.gov.
- Cables and Sensors. A Clinician's Guide to Reusable SpO2 Sensors, FAQ (accessed 2026-11-07). cablesandsensors.com.
Use only as directed in the Cables and Sensors labeling and the monitor maker instructions.1
| Item # | Image | Price | Quantity |
|---|---|---|---|
|
Cables and Sensors OxiMax Adapter Cable, Nellcor DEC-4 Compatible CAS-E704-710 |
$54.95 ea
|
|
| Item # | Image | Description | Quantity |
|---|


