ZOLL CPR Stat-padz HVP Electrodes, 8 Pairs per Case, 8900-0400
This item requires a clinical attestation, confirmed in your cart.
ZOLL CPR Stat-padz HVP multi-function CPR electrodes, part 8900-0400, come 8 pairs per case for crews that stock the adult electrode across several ZOLL defibrillators.12 Each pair has a CPR sensor and handles defibrillation, cardioversion, non-invasive pacing, CPR feedback and ECG monitoring, with a 24 month shelf life.31
Product Highlights:
- 8 pairs per case: Eight pairs of CPR Stat-padz HVP electrodes per case.12
- Multi-function: Defibrillation, cardioversion, non-invasive pacing, CPR feedback and ECG monitoring.3
- Works across ZOLL: Indicated with the AED Plus, AED Pro, AED 3, AED 3 BLS, R Series, X Series, X Series Advanced and Propaq MD.3
- 24 month shelf life: Shelf life is 24 months.1
- Latex-free: Not made with natural rubber latex.3
What Is in the Box:
Specifications:
| Part number | 8900-0400 (case); 8900-0402 (single pair)12 |
|---|---|
| Pack | 8 pairs per case1 |
| Manufacturer | ZOLL Medical Corporation2 |
| Function | Defibrillation, cardioversion, non-invasive pacing, CPR assistance and feedback, ECG monitoring3 |
| Indicated ZOLL devices | AED Plus, AED Pro, AED 3, AED 3 BLS, R Series, X Series, X Series Advanced, Propaq MD3 |
| Patient | Adults; not for patients under 8 years or under 55 lb (25 kg)3 |
| Shelf life | 24 months4 |
| Operating temperature | 0 to 50 C (32 to 122 F)3 |
| Storage temperature | Long term 0 to 35 C (32 to 95 F); short term -30 to 65 C (-22 to 149 F)3 |
| Wear time | Replace after 24 hours of skin contact or 8 hours of pacing3 |
| Natural rubber latex | Not made with natural rubber latex32 |
| MRI safety | MR Unsafe2 |
| Use | Single use2 |
| Device size | 9.3 x 8.5 x 1.0 in2 |
| GUDID DI | Case 10847946016316, holding 8 of DI 008479460163192 |
Related Products:
- ZOLL CPR Stat-padz HVP Multi-Function Electrodes, 1 Pair, 8900-0402
- ZOLL AED Plus Semi-Automatic with CPR-D-padz, 8000-004000-01
- ZOLL AED Plus Automatic with CPR-D-padz
- ZOLL CPR-D-padz One-Piece AED Plus Electrode, 8900-0800-01
- AEDs, Equipment and Supplies collection
Product Guides and Documents:
- CPR Stat-padz Instructions for Use, R2025-07 Rev. L (ZOLL)3
- CPR Stat-Padz Electrode, 8/Case, ZOLL WebStore item page1
Frequently Asked Questions:
How many electrodes are in a case of 8900-0400 (8900-0400)?
Eight pairs of CPR Stat-padz HVP electrodes.1 The FDA GUDID case record holds 8 of the single pair 8900-0402.2
Which ZOLL defibrillators are CPR Stat-padz compatible with (8900-0400)?
CPR Stat-padz are indicated for adult patients with the ZOLL AED Plus, AED Pro, AED 3, AED 3 BLS, R Series, X Series, X Series Advanced and Propaq MD.3 ZOLL WebStore compatibility for the part also covers the E Series and Propaq.1
What is the difference between CPR-D-padz and CPR Stat-padz (8900-0400)?
CPR Stat-padz are multi-function electrodes for defibrillation, cardioversion, non-invasive pacing, CPR feedback and ECG monitoring across several ZOLL defibrillators.3 CPR-D-padz are the one-piece AED Plus electrode with a five-year shelf life.5
Can CPR Stat-padz be used on children (8900-0400)?
No. CPR Stat-padz adult electrodes are not indicated for patients under 8 years of age or under 55 lb (25 kg).3 For a child, use pediatric electrode pads, which carry a lower charge.6
Where do you place CPR Stat-padz (8900-0400)?
Anterior-anterior: the anterior sternal pad on the upper right torso with the CPR sensor aligned to the sternal notch, and the anterior lateral pad below the pectoral muscle or under the breast. Anterior-posterior, which suits non-invasive pacing: posterior pad left of the spine below the scapula, anterior apical pad over the cardiac apex, with the CPR device on the sternal notch.3
How long can the electrodes stay on a patient (8900-0400)?
Replace them after 24 hours of skin contact or 8 hours of pacing.3
Can you do chest compressions on top of the pads (8900-0400)?
No. Do not compress through the electrodes; with the CPR sensor, place your hands directly on the sensor.3
Are CPR Stat-padz latex free (8900-0400)?
Yes. They are not made with natural rubber latex.3 They are single use and MR Unsafe.2
Do CPR Stat-padz expire (8900-0400)?
Yes. They have a 24 month shelf life; rotate case stock and do not use electrodes past the expiration date printed on the pouch label.13
Manufacturer Sources
- ZOLL Medical Corporation. ZOLL WebStore: CPR Stat-Padz Electrode, 8/Case, item 8900-0400 (accessed 2026-11-07). zollwebstore.com.
- U.S. Food and Drug Administration. AccessGUDID: CPR Stat-padz HVP Multi-Function CPR Electrodes 8900-0402, Zoll Medical Corporation, DI 00847946016319 (accessed 2026-11-07). accessgudid.nlm.nih.gov.
- ZOLL Medical Corporation. CPR Stat-padz Instructions for Use, R2025-07 Rev. L, January 2024 (accessed 2026-11-07). zoll.com.
- ZOLL Medical Corporation. ZOLL WebStore: CPR Stat-Padz Electrode, Single, item 8900-0402 (accessed 2026-11-07). zollwebstore.com.
- ZOLL Medical Corporation. ZOLL AED Plus (accessed 2026-11-07). zoll.com.
- ZOLL Medical Corporation. AED Plus Frequently Asked Questions (accessed 2026-11-07). zoll.com.
Specifications are from ZOLL and FDA GUDID records. Use only with ZOLL pacemaker and defibrillator products, as directed in the CPR Stat-padz instructions for use.3