ZOLL AccuVent Sensor for Real BVM Help, X Series Advanced, 10/Box

SKU: ZO-8000-001128-BX

The ZOLL AccuVent sensor, listed here as part 8000-001128, is the in-line flow sensor for Real BVM Help on the X Series Advanced monitor/defibrillator.1 Attached to the BVM circuit, it lets the monitor display ventilation rate and inspired volume for each manual breath.12 It is for adult patients and single use.1 We supply it with other BVM resuscitators and accessories.

Product Highlights:

  • Real BVM Help: Ventilation feedback by displaying ventilation rate and inspired volumes of manually delivered breaths.1
  • X Series Advanced: Real BVM Help requires the ZOLL AccuVent sensor and cable.1
  • Measurement range: Inspiratory volume 200 to 1000 mL; breath rate 4 to 40 BPM.1
  • Adult, single use: Adult patients only; single use; check the expiration date on the package.1
  • Manual ventilation only: Not for use with mechanical ventilators; not approved for use in aircraft.1

What Is in the Box:

  • 10 ZOLL AccuVent sensors (box of 10). The AccuVent interface cable is a separate ZOLL accessory.1

Specifications:

Manufacturer ZOLL Medical1
Part number 8000-001128
Use with X Series Advanced with Real BVM Help and the AccuVent sensor cable1
Inspiratory volume range 200 to 1000 mL1
Breath rate range 4 to 40 BPM1
Volume accuracy Greater of 50 mL or 20% of target1
Rate accuracy Plus or minus 3 BPM1
Operating temperature 0 to 50 C1
Patient Adult only1
Use Single use1
Pack 10 per box

Related Products:

Product Guides and Documents:

Frequently Asked Questions:

What is the ZOLL AccuVent sensor (8000-001128)?

An in-line flow sensor for ZOLL Real BVM Help. It measures air flow past the sensor so the X Series Advanced can show ventilation rate and inspired volume of manual breaths.1

Which monitor does AccuVent work with (8000-001128)?

The ZOLL X Series Advanced, through its AccuVent port and the AccuVent sensor cable.1

Is the AccuVent sensor reusable (8000-001128)?

No. The AccuVent flow sensor is single use. Clean the interface cable between uses.1

Can AccuVent be used on children (8000-001128)?

No. It is intended for adult patients only.1

Can it be used with a mechanical ventilator (8000-001128)?

No. The AccuVent sensor is not for use with mechanical ventilators.1

What range does it measure (8000-001128)?

Inspiratory volume 200 to 1000 mL and breath rate 4 to 40 BPM.1

How do I get accurate readings (8000-001128)?

Keep a tight seal between the mask and the patient, because the sensor measures air flow past it.1

Manufacturer Sources
  1. ZOLL Medical. X Series Advanced Operator's Guide, REF 9650-005355-01 Rev. A, November 2020 (accessed 2026-11-07). zoll.com.
  2. ZOLL Medical. Real BVM Help and AccuVent sensors (accessed 2026-11-07). zoll.com.

Adult use only, single use. Use only as directed in the ZOLL X Series Advanced Operator's Guide.1

Item # Image Price Quantity

ZOLL AccuVent Sensor for Real BVM Help, X Series Advanced, 10/Box

ZO-8000-001128-BX

ZOLL AccuVent sensor 8000-001128 for Real BVM Help, sensor in sealed pouch

$975.00

bx
Item # Image Description Quantity