Intersurgical i-view Disposable Video Laryngoscope, Macintosh Blade, One Adult Size, 8008000, 2/Box
Intersurgical i-view Disposable Video Laryngoscope, One Adult Size, 8008000
Product Highlights:
- One size, one code: One adult size, so there is no need to stock multiple sizes; code 8008000 is the only i-view code.12
- Single use, fully disposable: Reduces the risk of cross infection and avoids reprocessing costs, with no batteries to remove before disposal.2
- Ready in seconds: On/off switch; ready to use seconds after removal from the packaging.2
- Familiar Macintosh technique: Insertion is more familiar and instinctive than with hyper-angulated blades, and the i-view also works for direct laryngoscopy.2
- Integral LCD screen: Gives a view in a variety of light conditions, with a built-in camera and LED light.2
- Five year shelf life: Shelf life is five years from the date of manufacture, with the expiry date on the device itself, which suits pre-hospital kits and difficult airway carts where use is infrequent.32
- Protected for the bag or cart: Each device is individually packed in a rigid shell sealed with film for protection in transit and storage.2
What's Included:
- 2 i-view video laryngoscopes, each individually packed in a sealed rigid shell2
Specifications:
| Product | i-view video laryngoscope, single use1 |
|---|---|
| Manufacturer | Intersurgical Inc. |
| Code | 80080002 |
| Pacific Biomedical SKU | INT-8008000 |
| Size | One adult size1 |
| Blade | Macintosh2 |
| Display | Integral LCD screen2 |
| Imaging | Camera and LED light2 |
| Power | On/off button, held more than 0.5 seconds to switch off; automatic shut-off after 20 minutes of continuous use; no need to remove batteries prior to disposal32 |
| Shelf life | 5 years from date of manufacture3 |
| Bougie | Can be used with a bougie3 |
| Use | Single use, fully disposable14 |
| Sterility | Not packaged sterile4 |
| Latex | Not made with natural rubber latex4 |
| MRI | MR Unsafe4 |
| Lot and expiry | On the top edge above the LCD screen2 |
| Pack | 2 per box2 |
| GTIN | Box of 2: 05030267166497; each: 050302671506494 |
| Indication | Video or direct laryngoscopy for tracheal intubation, one adult size12 |
Use Cases:
- Pre-hospital and resuscitation airways in EMS and flight programs2
- Emergency department, intensive care and difficult airway carts2
- Anesthesia locations, including surgery centers and dental and oral surgery offices that provide deep sedation or general anesthesia25
- Sites where buying reusable video laryngoscopes for every location is not cost effective2
Related products:
- AirLife Bougie-To-Go adult endotracheal tube introducer, 15 Fr, 10/box: a bougie can be used with the i-view.3
- Adroit Surgical Tactical Bougie, 15 Fr, 10/box
- Rusch Safety Clear Plus cuffed endotracheal tube
- All airway management and suction
Videos:
Intersurgical's introduction to the i-view video laryngoscope:
The step-by-step i-view instruction video is on Intersurgical's i-view page. It shows the basic steps for use and does not replace the instructions for use.6
Frequently Asked Questions:
What is the i-view video laryngoscope?
It is Intersurgical's single use, fully disposable video laryngoscope, with an integral LCD screen, a camera and LED light, and a Macintosh blade, so it supports video and direct laryngoscopy.12
What sizes does the i-view come in?
One adult size only. Intersurgical lists a single code, 8008000, supplied in boxes of 2, so there is no need to stock multiple sizes.12
Is the i-view reusable, and does it need a separate handle or monitor?
No. It is single use and fully disposable, with the screen built into the handle, and it is ready to use seconds after it comes out of the package.2 The on/off button must be held for more than 0.5 seconds to switch it off, which prevents accidental shut-off during use, and the device turns itself off after 20 minutes of continuous use.3 There are no batteries to remove before disposal, and there is no reprocessing.2
Is video laryngoscopy better than direct laryngoscopy?
In the DEVICE trial of 1,417 critically ill adults intubated in emergency departments and ICUs, first-attempt success was 85.1% with a video laryngoscope and 70.8% with a direct laryngoscope, with similar rates of severe complications.7 That trial tested video laryngoscopes as a class. For the i-view itself, the published evidence is small: a 2017 King's College Hospital conference poster of 30 adult surgical patients reported 86.7% first attempt success, a 2020 randomized controlled study in super-obese patients (BMI above 50 kg/m2) found safe and effective intubation, and a 2020 retrospective series of 20 COVID-19 patients reported 18 first pass intubations with no failures.3
Why a Macintosh blade instead of a hyper-angulated blade?
The Macintosh blade makes insertion more familiar and instinctive than with hyper-angulated devices, and it lets the same device be used for direct laryngoscopy.2 The Macintosh geometry also aligns the axes for tube placement at the cords, a bougie can still be used, and the screen lets an assistant guide external laryngeal manipulation.3
Is the i-view a good prehospital video laryngoscope for EMS?
It is built for pre-hospital, emergency medicine and resuscitation use: one size, ready in seconds, single use, and individually packed in a rigid shell that protects it in transit and storage.2 Its five year shelf life from the date of manufacture suits ambulances, aircraft and airway bags where the device may sit unused for long periods.3
Does a dental or oral surgery office need a video laryngoscope?
For deep sedation and general anesthesia, ADA guidelines require that the equipment and drugs needed for advanced airway management and advanced cardiac life support be immediately available.5 A single use video laryngoscope like the i-view is one option for that advanced airway equipment, giving a dental or oral and maxillofacial surgery office video laryngoscopy without buying a reusable system.2
Is the i-view sterile, latex-free and MRI safe?
It is not packaged sterile, it is not made with natural rubber latex, and it is MR Unsafe, so keep it out of the MRI room.4 The lot number and expiry date are on the top edge above the LCD screen.2
Is there a video showing how to use the i-view?
Yes. Intersurgical publishes two: a short introduction to the i-view, embedded above, and an i-view instruction video that walks through the basic steps for use and summarizes the key benefits.6 The instruction video is a guide and does not replace the instructions for use.6
Is this a genuine Intersurgical i-view?
Yes. This is the new Intersurgical i-view video laryngoscope, code 8008000, in the original box of 2.2 Pacific Biomedical supplies Intersurgical airway products.
How fast does this ship?
Prepaid, in-stock orders placed before 12:00 PM Arizona time typically ship the same business day via UPS within the United States, and shipping cost is calculated at checkout. For lead times or expedited options, contact CustomerService@pacificbiomedical.com or 844.436.3526.
How do I order for an agency, hospital or practice?
Add it to your cart on this page, or contact CustomerService@pacificbiomedical.com or 844.436.3526 for a purchase order or pricing on multiple boxes.
References
- Intersurgical Inc. i-view video laryngoscope (video laryngoscopy product page: one adult size; single use; fully disposable; Macintosh blade; ideal for pre-hospital, emergency medicine, resuscitation, anesthesia and intensive care; code 8008000, box quantity 2). Accessed October 30, 2026. intersurgicalinc.com.
- Intersurgical Inc. i-view video laryngoscope information sheet. U.S. Lit No. 198.2 / IS6.15 US, Issue 3. April 2024 (one size; single use; fully disposable; pre-hospital, emergency medicine, resuscitation, anesthesia, difficult airway, intensive care; Macintosh blade for video and direct laryngoscopy; insertion more familiar than hyper-angulated blades; ready seconds after removal from packaging; integral LCD screen; camera and LED light; on/off switch; no need to remove batteries prior to disposal; cost-effective where reusable devices for multiple sites are limited; boxes of 2; individually packed rigid shell; lot and expiry on the top edge above the screen). Accessed October 30, 2026. intersurgicalinc.com.
- Intersurgical Ltd. i-view product improvements and published evidence (on/off button held more than 0.5 seconds; automatic switch-off after 20 minutes of continuous use; shelf life five years from date of manufacture; expiry etched on the device; bougie can be used; King's College Hospital 30-patient poster, first attempt success 86.7%; Gaszynski 2020 randomized study in super-obese patients; Corso 2020 COVID-19 series, 18/20 first pass, no failures). Accessed October 30, 2026. ie.intersurgical.com.
- US Food and Drug Administration, National Library of Medicine. AccessGUDID: I-VIEW VIDEO LARYNGOSCOPE, model 8008000, Intersurgical Incorporated, primary DI 05030267150649 (single use; not packaged sterile; not made with natural rubber latex; MR Unsafe; FDA product code CCW). Accessed October 30, 2026. accessgudid.nlm.nih.gov.
- American Dental Association. Guidelines for the Use of Sedation and General Anesthesia by Dentists. Adopted October 2016 (deep sedation and general anesthesia: equipment and drugs necessary to provide advanced airway management and advanced cardiac life support must be immediately available). Accessed October 30, 2026. ada.org.
- Intersurgical Inc. i-view video laryngoscope (product videos: "i-view video laryngoscope" and "i-view video laryngoscopy instruction video," which shows how the i-view should be used, incorporates a brief summary of the key benefits, and does not replace the instructions for use; code 8008000, box quantity 2). Accessed October 31, 2026. us.intersurgical.com.
- Prekker ME, Driver BE, Trent SA, et al. Video versus direct laryngoscopy for tracheal intubation of critically ill adults. N Engl J Med. 2023;389(5):418-429. doi:10.1056/NEJMoa2301601. pubmed.ncbi.nlm.nih.gov.
Follow the Intersurgical instructions for use.
| Item # | Image | Price | Quantity |
|---|---|---|---|
|
Intersurgical i-view Disposable Video Laryngoscope, Macintosh Blade, One Adult Size, 8008000, 2/Box INT-8008000 |
|
$270.00 bx/2
|
|