Every GO-PAP kit has the same generator, PEEP valve and oxygen tube. The part number tells you the mask size, the headgear and whether the nebulizer and Neb-Connect are included. Each part number is a box of 10 kits.2 No suffix means no nebulizer, N adds the nebulizer on a second oxygen flow at 8 LPM, and NC adds the Neb-Connect so one cylinder runs both.34 Standard is strap headgear and CAP is mesh cap headgear (see the headgear image). Shop opens the kit page. Quote sends the part number to our customer service.
| Part Number | Mask, Headgear | Nebulizer | Order |
|---|---|---|---|
| 313-4601 | Small, Standard | None | Shop |
| 313-4602 | Medium, Standard | None | Shop |
| 313-4602N | Medium, Standard | Nebulizer | Shop |
| 313-4602NC | Medium, Standard | Nebulizer and Neb-Connect | Shop |
| 313-4603N | Large, Standard | Nebulizer | Shop |
| 313-4603NC | Large, Standard | Nebulizer and Neb-Connect | Shop |
| 313-4601N | Small, Standard | Nebulizer | Quote |
| 313-4603 | Large, Standard | None | Quote |
| 313-4604 | Medium, CAP | None | Quote |
| 313-4604N | Medium, CAP | Nebulizer | Quote |
| 313-4604NC | Medium, CAP | Nebulizer and Neb-Connect | Quote |
| 313-4605 | Large, CAP | None | Quote |
| 313-4605N | Large, CAP | Nebulizer | Quote |
| 313-4605NC | Large, CAP | Nebulizer and Neb-Connect | Quote |
| Oxygen source | Metered-flow oxygen supply set to 10 LPM, connected with the included oxygen supply tube. Oxygen only.1 |
|---|---|
| Nebulizer gas | A second oxygen flow at 8 LPM, or the Neb-Connect on the regulator's 50 psi DISS port (6 to 8 LPM).3624 |
| Masks | BiTrac ED, adult small, medium or large, with standard or CAP headgear. Replacement masks: 313-7028, 313-7029, 313-7030.2 |
| Patients | Spontaneously breathing adults over 30 kg.1 |
| Care settings | Hospital and prehospital (EMS).1 |
| Manufacturer | Pulmodyne Inc., Indianapolis, Indiana |
|---|---|
| Device | Fixed-flow venturi CPAP generator with an integrated PEEP valve and nebulizer port1 |
| PEEP | 5, 7.5 or 10 cmH2O, adjustable, independent of flow2 |
| Oxygen flow | 10 LPM. Do not exceed 10 LPM.1 |
| Total flow to patient | About 90 LPM2 |
| FiO2 | About 30%2 |
| Run time | About 40 minutes on a D cylinder2 |
| Nebulizer flow | 8 LPM3 |
| Neb-Connect | 50 psi DISS port, 6 to 8 LPM, on/off switch24 |
| Mask | BiTrac ED, adult small, medium or large2 |
| Headgear | Standard (313-4601 to 313-4603) or CAP (313-4604, 313-4605)2 |
| Patients | Spontaneously breathing adults over 30 kg1 |
| Use | Single patient use. Do not sterilize or immerse.1 |
| Operating conditions | 5 to 40 degrees C (41 to 104 degrees F), 15% to 95% humidity1 |
| Storage conditions | -20 to 60 degrees C (-4 to 140 degrees F), up to 95% relative humidity, non-condensing1 |
| FDA product code | BYE (Attachment, Breathing, Positive End Expiratory Pressure)7 |
| Box quantity | 10 kits per box2 |
| Made in | USA1 |
Disposable EMS CPAP comes in two common designs. A flow-set CPAP turns the oxygen flowmeter into the pressure control: more oxygen flow, more PEEP, checked on a manometer. The GO-PAP separates the two: oxygen stays at 10 LPM and PEEP is a dial on the generator.4 The table compares the GO-PAP with a flow-set disposable CPAP that has a built-in color-coded manometer and an integrated-nebulizer version. Flow-set values come from that design's published flow-to-PEEP chart and instructions.
| Feature | Pulmodyne GO-PAP | Flow-set disposable CPAP (PEEP set by oxygen flow) |
|---|---|---|
| How PEEP is set | Knob on the generator: 5, 7.5 or 10 cmH2O, independent of flow54 | Raise or lower oxygen flow on the flowmeter, then read the manometer |
| Oxygen flow at 5 cmH2O | 10 LPM1 | About 8 to 9 LPM |
| Oxygen flow at 10 cmH2O | 10 LPM1 | About 13 to 14 LPM |
| Turning on the nebulizer | Generator flow stays at 10 LPM and PEEP stays independent of flow.5 N kits add 8 LPM on a second flow (about 18 LPM of oxygen in all). NC kits add 6 to 8 LPM from the same cylinder through the Neb-Connect (about 16 to 18 LPM).34 | Integrated-nebulizer version: CPAP pressure drops when the nebulizer turns on. About 15 to 16 LPM holds only 5 cmH2O, and about 24 to 25 LPM is needed for 10 cmH2O |
| D cylinder run time | About 40 minutes at 10 LPM2 | About 40 minutes at 5 cmH2O, shorter at higher PEEP |
| FiO2 | About 30%2 | Varies with breathing, about 70 to 75% in CPAP mode for an average adult |
| Pressure check | Built-in mechanical PEEP valve. No manometer in the kit.51 | Built-in color-coded manometer, read to confirm PEEP |
| Patients | Adults over 30 kg1 | Adult and child mask sizes |
| Care settings | Hospital and prehospital (EMS)1 | Hospital and prehospital |
Need more flow or a higher FiO2? Pulmodyne's O2-MAX disposable CPAP system delivers up to 140 LPM, connects to a 50 psi oxygen source rather than a flowmeter,8 takes 3-SET or 5-SET PEEP valves up to 15 cmH2O, filters bacteria and viruses, and selects 30, 60 or 90% FiO2 with the Trio adapter.9
The GO-PAP is a fixed-flow venturi CPAP. Oxygen at 10 LPM drives the generator, which entrains room air and delivers about 90 LPM to the mask at about 30% FiO2. A built-in mechanical PEEP valve holds 5, 7.5 or 10 cmH2O through inspiration and exhalation, independent of the patient's flow.125
10 LPM. Connect the oxygen tubing directly to the low-pressure port or flowmeter of the oxygen source and set 10 LPM. Do not exceed 10 LPM. The regulator's 50 psi DISS port is for the Neb-Connect on NC kits. At 10 LPM a D cylinder lasts about 40 minutes.512
Turn the GO-PAP knob clockwise or counterclockwise to 5.0, 7.5 or 10 cmH2O. The mechanical PEEP valve sets PEEP, so oxygen flow stays at 10 LPM at every setting. Set and adjust PEEP per local protocol.5
About 40 minutes on a full D cylinder at 10 LPM. Running the nebulizer from the same cylinder with the Neb-Connect adds 6 to 8 LPM, so the cylinder empties sooner while the nebulizer runs.524
About 30%. The venturi mixes 10 LPM of oxygen with entrained room air for about 90 LPM of total flow. For a selectable 30, 60 or 90% FiO2, the Pulmodyne O2-MAX system uses the Trio adapter.29
Use an NC kit. Connect the Neb-Connect to the regulator's 50 psi port, add the medication to the nebulizer canister, run its supply tubing to the Neb-Connect, then push the canister into the GO-PAP nebulizer port with a quarter turn and check that the pop-up valve is open. Turn the white Neb-Connect valve counterclockwise to start about 6 to 8 LPM. N kits run the canister from a second oxygen flow at 8 LPM.53
Medium is the most universal adult size, and GO-PAP kits come with adult small, medium or large BiTrac ED masks. To check fit, seat the mask at reading-glass level, adjust the Omni Clip so the forehead pad sits just above the eyebrows, and confirm the lower edge sits just below the lower lip.52
A leak may mean the mask size is wrong, so check the size first. Then check the fit. The BiTrac ED mask is designed to float on the face with a double silicone lip, so headgear pulled too tight can cause a leak. Make sure the seal is not crumpled against the face.5
Yes, when trained and within protocol. The GO-PAP is labeled for thoroughly trained personnel in the hospital and prehospital (EMS) environment, and hospital units such as the ED and PACU follow facility protocol.1 The 2019 National EMS Scope of Practice Model places CPAP devices at the EMT level, and each state sets its own scope and agency protocol.10
The GO-PAP may be contraindicated with facial lacerations, laryngeal trauma, recent tracheal or esophageal anastomosis, gastrointestinal bleeding or ileus, recent gastric surgery, basilar skull fracture, high risk of vomiting, emphysematous bulla or hypovolemia. It is for spontaneously breathing adults over 30 kg.1
Yes. We are an authorized Pulmodyne distributor. Every GO-PAP ships new in its original Pulmodyne packaging.
Most orders ship within 1 to 2 business days. Expedited and overnight shipping are available at checkout.
Select Shop beside a part number in the kit chart to open its kit page and add it to your cart. For a kit marked Quote, use that link, or contact CustomerService@pacificbiomedical.com or 844.436.3526 with the part number. We support net terms for agencies and hospitals and ship to all 50 states.
| Item # | Image | Quantity | |||
|---|---|---|---|---|---|
![]() |
$648.28 10-bx |
||||
![]() |
$648.28 10-bx |
||||
![]() |
$665.82 10-bx |
||||
![]() |
$743.39 10-bx |
||||
![]() |
$665.82 10-bx |
||||
![]() |
$743.39 10-bx |
||||