{"product_id":"o2-max","title":"Pulmodyne O2-MAX Disposable CPAP System for EMS and Hospital Use","description":"\u003cdiv class=\"pbm-product pbm-ax\"\u003e\n\u003cdiv class=\"pbm-lead\"\u003eThe \u003cstrong\u003ePulmodyne O2-MAX\u003c\/strong\u003e is a disposable, single-patient-use CPAP system for spontaneously breathing adults over 30 kg in hospital and prehospital (EMS) care. Its fixed-flow venturi generator runs on a 50 psi oxygen source, delivers up to 140 LPM at about 30% FiO2, and holds PEEP with a 3-SET, 5-SET or fixed valve, independent of the patient's flow.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e Air is filtered in both directions.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e Pacific Biomedical offers O2-MAX part numbers \u003cspan class=\"nw\"\u003e313-7538X\u003c\/span\u003e, \u003cspan class=\"nw\"\u003e313-7554XN-1\u003c\/span\u003e, \u003cspan class=\"nw\"\u003e313-7555X\u003c\/span\u003e, \u003cspan class=\"nw\"\u003e313-7555XN-1\u003c\/span\u003e, \u003cspan class=\"nw\"\u003e313-7556X\u003c\/span\u003e, \u003cspan class=\"nw\"\u003e313-7556XN-1\u003c\/span\u003e and \u003cspan class=\"nw\"\u003e313-7557XN-1\u003c\/span\u003e to order online in cases of 10 systems, and the rest of the O2-MAX line, including O2-MAX Trio, by quote.\u003c\/div\u003e\n\u003ch2\u003eChoose Your O2-MAX System:\u003c\/h2\u003e\n\u003cp\u003eEach part number is a case of 10 complete systems: generator with inhalation filter, 72 in circuit, PEEP valve, BiTrac ED mask with headgear and O2-MAX Guard exhalation filter.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e N adds the nebulizer, -1 adds a pre-attached Ohmeda Quik-Connect, and X is the expandable circuit.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e Shop opens the system page. Quote sends the part number to Pacific Biomedical customer service.\u003c\/p\u003e\n\u003ctable class=\"pbm-table\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003ePart Number\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMask, PEEP\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eNeb, Fitting\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eOrder\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003ca class=\"nw\" href=\"\/products\/pi-313-7538x\"\u003e313-7538X\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMedium, 10 cmH2O\u003c\/td\u003e\n\u003ctd\u003eNo, DISS\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pi-313-7538x\"\u003eShop\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003ca class=\"nw\" href=\"\/products\/pi-313-7554xn-1\"\u003e313-7554XN-1\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLarge, \u003cspan class=\"nw\"\u003e5-SET\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003eYes, Quik-Connect\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pi-313-7554xn-1\"\u003eShop\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003ca class=\"nw\" href=\"\/products\/pi-313-7555x\"\u003e313-7555X\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLarge, \u003cspan class=\"nw\"\u003e3-SET\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003eNo, DISS\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pi-313-7555x\"\u003eShop\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003ca class=\"nw\" href=\"\/products\/pi-313-7555xn-1\"\u003e313-7555XN-1\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLarge, \u003cspan class=\"nw\"\u003e3-SET\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003eYes, Quik-Connect\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pi-313-7555xn-1\"\u003eShop\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003ca class=\"nw\" href=\"\/products\/pi-313-7556x\"\u003e313-7556X\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMedium, \u003cspan class=\"nw\"\u003e3-SET\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003eNo, DISS\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pi-313-7556x\"\u003eShop\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003ca class=\"nw\" href=\"\/products\/pi-313-7556xn-1\"\u003e313-7556XN-1\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMedium, \u003cspan class=\"nw\"\u003e3-SET\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003eYes, Quik-Connect\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pi-313-7556xn-1\"\u003eShop\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003ca class=\"nw\" href=\"\/products\/pi-313-7557xn-1\"\u003e313-7557XN-1\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMedium, \u003cspan class=\"nw\"\u003e5-SET\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003eYes, Quik-Connect\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pi-313-7557xn-1\"\u003eShop\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"nw\"\u003e313-7554X\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLarge, \u003cspan class=\"nw\"\u003e5-SET\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003eNo, DISS\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pages\/contact-us?quote=313-7554X\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-7554X\"\u003eQuote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"nw\"\u003e313-7554XN\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLarge, \u003cspan class=\"nw\"\u003e5-SET\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003eYes, DISS\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pages\/contact-us?quote=313-7554XN\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-7554XN\"\u003eQuote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"nw\"\u003e313-7555XN\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLarge, \u003cspan class=\"nw\"\u003e3-SET\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003eYes, DISS\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pages\/contact-us?quote=313-7555XN\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-7555XN\"\u003eQuote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"nw\"\u003e313-7556XN\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMedium, \u003cspan class=\"nw\"\u003e3-SET\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003eYes, DISS\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pages\/contact-us?quote=313-7556XN\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-7556XN\"\u003eQuote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"nw\"\u003e313-7557X\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMedium, \u003cspan class=\"nw\"\u003e5-SET\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003eNo, DISS\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pages\/contact-us?quote=313-7557X\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-7557X\"\u003eQuote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"nw\"\u003e313-7557XN\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMedium, \u003cspan class=\"nw\"\u003e5-SET\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003eYes, DISS\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pages\/contact-us?quote=313-7557XN\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-7557XN\"\u003eQuote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eWhich fitting do I need?\u003c\/strong\u003e Every O2-MAX needs a 50 psi oxygen source, not a flowmeter.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOhmeda wall outlet:\u003c\/strong\u003e choose a -1 part number. The Ohmeda Quik-Connect comes attached.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCylinder regulator with a 50 psi DISS outlet:\u003c\/strong\u003e choose a part number without -1: 313-7538X, 313-7555X or 313-7556X, or with a nebulizer 313-7554XN, 313-7555XN, 313-7556XN or 313-7557XN by quote.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-4\"\u003e4\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChemetron, Puritan Bennett or Schrader wall outlet:\u003c\/strong\u003e choose a part number without -1 and add the matching Quik-Connect: \u003ca class=\"nw\" href=\"\/pages\/contact-us?quote=313-121111\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-121111\"\u003e313-121111\u003c\/a\u003e, \u003ca class=\"nw\" href=\"\/pages\/contact-us?quote=313-131111\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-131111\"\u003e313-131111\u003c\/a\u003e or \u003ca class=\"nw\" href=\"\/pages\/contact-us?quote=313-141111\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-141111\"\u003e313-141111\u003c\/a\u003e (by quote).\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-5\"\u003e5\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eO2-MAX Trio Systems:\u003c\/h2\u003e\n\u003cp\u003eTrio systems add a knob that sets about 30, 60 or 90%+ FiO2. They come with an expandable circuit, with or without the nebulizer.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-6\"\u003e6\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e The Trio control unit, part number 313-8000, converts a Fixed generator to a Trio, and cannot be used alone.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-7\"\u003e7\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-8\"\u003e8\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e All Trio part numbers are by quote.\u003c\/p\u003e\n\u003ctable class=\"pbm-table\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003ePart Number\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMask, PEEP\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eNeb, Fitting\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eOrder\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"nw\"\u003e313-8007X\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMedium, \u003cspan class=\"nw\"\u003e3-SET\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003eNo, DISS\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pages\/contact-us?quote=313-8007X\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-8007X\"\u003eQuote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"nw\"\u003e313-8007XN\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMedium, \u003cspan class=\"nw\"\u003e3-SET\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003eYes, DISS\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pages\/contact-us?quote=313-8007XN\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-8007XN\"\u003eQuote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"nw\"\u003e313-8007XN-1\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMedium, \u003cspan class=\"nw\"\u003e3-SET\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003eYes, Quik-Connect\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pages\/contact-us?quote=313-8007XN-1\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-8007XN-1\"\u003eQuote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"nw\"\u003e313-8008XN\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMedium, \u003cspan class=\"nw\"\u003e5-SET\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003eYes, DISS\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pages\/contact-us?quote=313-8008XN\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-8008XN\"\u003eQuote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"nw\"\u003e313-8017X\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLarge, \u003cspan class=\"nw\"\u003e3-SET\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003eNo, DISS\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pages\/contact-us?quote=313-8017X\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-8017X\"\u003eQuote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"nw\"\u003e313-8017XN\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLarge, \u003cspan class=\"nw\"\u003e3-SET\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003eYes, DISS\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pages\/contact-us?quote=313-8017XN\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-8017XN\"\u003eQuote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"nw\"\u003e313-8017XN-1\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLarge, \u003cspan class=\"nw\"\u003e3-SET\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003eYes, Quik-Connect\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pages\/contact-us?quote=313-8017XN-1\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-8017XN-1\"\u003eQuote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"nw\"\u003e313-8018XN\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLarge, \u003cspan class=\"nw\"\u003e5-SET\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003eYes, DISS\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pages\/contact-us?quote=313-8018XN\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-8018XN\"\u003eQuote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"nw\"\u003e313-8000\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControl unit only\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pages\/contact-us?quote=313-8000\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-8000\"\u003eQuote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eProduct Highlights:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh flow from a 50 psi source.\u003c\/strong\u003e The venturi generator connects directly to a 50 psi oxygen source and entrains room air to deliver up to 140 LPM at about 30% FiO2. The PEEP valves maintain positive pressure at flows from 60 to 140 LPM.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePEEP set by the valve, not the flowmeter.\u003c\/strong\u003e \u003cspan class=\"nw\"\u003e3-SET\u003c\/span\u003e (5, 7.5, 10), \u003cspan class=\"nw\"\u003e5-SET\u003c\/span\u003e (5 to 15) or fixed valves (2.5 to 20 cmH2O) hold PEEP independent of the patient's flow rate.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-9\"\u003e9\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiltered in and out.\u003c\/strong\u003e An inhalation filter on the generator and the pre-attached O2-MAX Guard exhalation filter. Filter efficiency is more than 99.99% bacterial and viral.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNebulize during CPAP.\u003c\/strong\u003e N systems include a nebulizer canister that pushes into the nebulizer port with a quarter turn. The filter sits before the nebulizer port, so it saturates with medication less than an in-line filter would, and flow to the patient stays consistent.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 28 minutes on a D cylinder\u003c\/strong\u003e (Fixed system), or run it from the vehicle or hospital wall outlet.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-5\"\u003e5\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelect 30, 60 or 90% FiO2 with Trio.\u003c\/strong\u003e Trio systems, or a Fixed generator fitted with the Trio control unit (313-8000), set about 30, 60 or 90%+ FiO2 with a knob.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-6\"\u003e6\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-8\"\u003e8\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-7\"\u003e7\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReady to apply.\u003c\/strong\u003e No assembly. The BiTrac ED mask comes with pre-attached headgear and the adjustable Omni Clip, on a 72 in anti-asphyxia circuit with expandable tubing. Check airflow and valve function before use.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-9\"\u003e9\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-10\"\u003e10\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuik-Connect ready.\u003c\/strong\u003e -1 systems come with a disposable Ohmeda Quik-Connect that plugs into an Ohmeda wall outlet and moves with the patient from bedside to ambulance.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-5\"\u003e5\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-9\"\u003e9\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWorks With:\u003c\/h2\u003e\n\u003ctable class=\"pbm-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOxygen source\u003c\/th\u003e\n\u003ctd\u003e50 psi (about 4 bar) oxygen only. Connect directly to a 50 psi outlet: an ambulance or hospital wall outlet, or a cylinder regulator with a 50 psi DISS outlet such as the \u003ca href=\"\/products\/gt-284ma-15ly1\"\u003eGentec 284MA-15LY1\u003c\/a\u003e. It connects to the 50 psi outlet, not to a flowmeter barb.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-4\"\u003e4\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection\u003c\/th\u003e\n\u003ctd\u003ePart numbers without -1 (such as 313-7555X): DISS connection on the oxygen hose. Part numbers with -1 (such as 313-7554XN-1): Ohmeda Quik-Connect, pre-attached. Replacement \u003ca href=\"\/products\/pi-313-111111\"\u003eOhmeda Quik-Connect 313-111111\u003c\/a\u003e, case of 30.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-5\"\u003e5\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMasks\u003c\/th\u003e\n\u003ctd\u003eBiTrac ED, adult medium or large, ships with the system. Replacement masks: \u003ca href=\"\/products\/pi-313-7028\"\u003e313-7028\u003c\/a\u003e small, \u003ca href=\"\/products\/pi-313-7029\"\u003e313-7029\u003c\/a\u003e medium, \u003ca href=\"\/products\/pi-313-7030\"\u003e313-7030\u003c\/a\u003e large.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePEEP valves\u003c\/th\u003e\n\u003ctd\u003eSnap onto the anti-asphyxia housing end of the circuit, seated fully onto the O2-MAX Guard filter. See the valve chart below.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-10\"\u003e10\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMonitoring\u003c\/th\u003e\n\u003ctd\u003eNo gauge in the kit: add an in-line pressure gauge or manometer, 0 to 30 cmH2O, per local protocol, plus SpO2.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e NASEMSO guidelines call for pulse oximetry and EtCO2 in respiratory distress.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-11\"\u003e11\u003c\/a\u003e\u003c\/sup\u003e Pacific Biomedical carries \u003ca href=\"\/products\/al-4msf1-7-6-25\"\u003eAirLife adult EtCO2\/O2 sampling cannulas\u003c\/a\u003e.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePatients\u003c\/th\u003e\n\u003ctd\u003eSpontaneously breathing adults over 30 kg.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCare settings\u003c\/th\u003e\n\u003ctd\u003eHospital and prehospital (EMS).\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003ePEEP Valves and Colors:\u003c\/h2\u003e\n\u003cp\u003eO2-CPAP valves snap onto the end of the O2-MAX circuit and maintain positive pressure at flows from 60 to 140 LPM.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e Swap a valve to change PEEP, or replace a valve that becomes occluded.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-12\"\u003e12\u003c\/a\u003e\u003c\/sup\u003e Each valve part number is a case of 10.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-13\"\u003e13\u003c\/a\u003e\u003c\/sup\u003e The standalone O2-MAX Guard exhalation filter is part number \u003cspan class=\"nw\"\u003e313-8300\u003c\/span\u003e (\u003ca href=\"\/pages\/contact-us?quote=313-8300\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-8300\"\u003eQuote\u003c\/a\u003e).\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\n\u003ctable class=\"pbm-table\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003ePart Number\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValve, PEEP (cmH2O)\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eColor\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eOrder\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"nw\"\u003e313-7725\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-SET adjustable, 5, 7.5 or 10\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pages\/contact-us?quote=313-7725\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-7725\"\u003eQuote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"nw\"\u003e313-7730\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-SET adjustable, 5, 7.5, 10, 12.5 or 15\u003c\/td\u003e\n\u003ctd\u003eGray\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pages\/contact-us?quote=313-7730\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-7730\"\u003eQuote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"nw\"\u003e313-7715\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, 2.5\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pages\/contact-us?quote=313-7715\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-7715\"\u003eQuote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"nw\"\u003e313-7716\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, 5.0\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pages\/contact-us?quote=313-7716\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-7716\"\u003eQuote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"nw\"\u003e313-7717\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, 7.5\u003c\/td\u003e\n\u003ctd\u003eYellow\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pages\/contact-us?quote=313-7717\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-7717\"\u003eQuote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"nw\"\u003e313-7718\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, 10.0\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pages\/contact-us?quote=313-7718\u0026amp;brand=Pulmodyne#contact_form\" rel=\"nofollow\" aria-label=\"Request a quote for 313-7718\"\u003eQuote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003ca class=\"nw\" href=\"\/products\/pi-313-7719\"\u003e313-7719\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, 12.5\u003c\/td\u003e\n\u003ctd\u003ePink\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pi-313-7719\"\u003eShop\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003ca class=\"nw\" href=\"\/products\/pi-313-7720\"\u003e313-7720\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, 15.0\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pi-313-7720\"\u003eShop\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003ca class=\"nw\" href=\"\/products\/pi-313-7721\"\u003e313-7721\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed, 20.0\u003c\/td\u003e\n\u003ctd\u003eGold\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pi-313-7721\"\u003eShop\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSpecifications:\u003c\/h2\u003e\n\u003ctable class=\"pbm-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003ePulmodyne Inc., Indianapolis, Indiana\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDevice\u003c\/th\u003e\n\u003ctd\u003eFixed-flow venturi CPAP generator with inhalation filter, 72 in anti-asphyxia circuit, O2-CPAP PEEP valve and O2-MAX Guard exhalation filter\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOxygen source\u003c\/th\u003e\n\u003ctd\u003e50 psi (about 4 bar), oxygen only\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow to patient\u003c\/th\u003e\n\u003ctd\u003eUp to 140 LPM; lower with the Guard filter attached\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFiO2\u003c\/th\u003e\n\u003ctd\u003eAbout 30% (Fixed). About 30, 60 or 90%+ (Trio).\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-6\"\u003e6\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePEEP\u003c\/th\u003e\n\u003ctd\u003e3-SET 5, 7.5 or 10 cmH2O. 5-SET 5, 7.5, 10, 12.5 or 15 cmH2O. Fixed valves 2.5 to 20 cmH2O.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-9\"\u003e9\u003c\/a\u003e\u003c\/sup\u003e With the Guard filter attached, delivered PEEP runs about 1.5 cmH2O above the valve setting.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRun time\u003c\/th\u003e\n\u003ctd\u003eUp to 28 minutes on a D cylinder (Fixed system)\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFiltration\u003c\/th\u003e\n\u003ctd\u003eInhalation filter and pre-attached O2-MAX Guard exhalation filter. Filter efficiency more than 99.99% bacterial and viral. Replace the Guard filter at least every 24 hours.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-10\"\u003e10\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNebulizer\u003c\/th\u003e\n\u003ctd\u003eIncluded on N systems; the canister pushes into the nebulizer port\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMask\u003c\/th\u003e\n\u003ctd\u003eBiTrac ED, adult medium or large, pre-attached headgear with Omni Clip\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-9\"\u003e9\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCircuit\u003c\/th\u003e\n\u003ctd\u003e72 in anti-asphyxia circuit, expandable tubing\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection\u003c\/th\u003e\n\u003ctd\u003eDISS, or Ohmeda Quik-Connect on -1 systems\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePatients\u003c\/th\u003e\n\u003ctd\u003eSpontaneously breathing adults over 30 kg\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eSingle patient use. No assembly. Do not sterilize or immerse.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating conditions\u003c\/th\u003e\n\u003ctd\u003e5 to 40 degrees C (41 to 104 degrees F), 15% to 95% humidity\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStorage conditions\u003c\/th\u003e\n\u003ctd\u003e-20 to 60 degrees C (-4 to 140 degrees F), up to 95% relative humidity, non-condensing\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFDA product code\u003c\/th\u003e\n\u003ctd\u003eBYE (Attachment, Breathing, Positive End Expiratory Pressure)\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-14\"\u003e14\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCase quantity\u003c\/th\u003e\n\u003ctd\u003e10 systems per case\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eO2-MAX vs Flow-Set Disposable CPAP:\u003c\/h2\u003e\n\u003cp\u003eDisposable EMS CPAP comes in two common designs. A flow-set CPAP uses the oxygen flowmeter as the pressure control: more oxygen flow, more PEEP, checked on a manometer. The O2-MAX separates the two: a 50 psi oxygen source drives a high-flow venturi, and the valve on the circuit sets PEEP.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-9\"\u003e9\u003c\/a\u003e\u003c\/sup\u003e The table compares the O2-MAX with a flow-set disposable CPAP that has a built-in color-coded manometer and an integrated-nebulizer version. Flow-set values come from that design's published flow-to-PEEP chart and instructions.\u003c\/p\u003e\n\u003ctable class=\"pbm-table\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePulmodyne O2-MAX\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFlow-set disposable CPAP (PEEP set by oxygen flow)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHow PEEP is set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eValve on the circuit: 3-SET (5, 7.5, 10), 5-SET (5 to 15) or fixed (2.5 to 20 cmH2O), independent of the patient's flow\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-9\"\u003e9\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eRaise or lower oxygen flow on the flowmeter, then read the manometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOxygen source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 psi outlet: wall outlet or a regulator's 50 psi DISS port\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eFlowmeter, about 8 to 9 LPM for 5 cmH2O and 13 to 14 LPM for 10 cmH2O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlow to the patient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 140 LPM. Valves hold PEEP at 60 to 140 LPM.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eSet by the oxygen flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiO2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAbout 30% (Fixed). About 30, 60 or 90%+ with Trio.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-6\"\u003e6\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eVaries with breathing, about 70 to 75% in CPAP mode for an average adult\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTurning on the nebulizer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNebulizer canister in the nebulizer port at the mask end of the circuit, with a consistent flow to the patient\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eIntegrated-nebulizer version: CPAP pressure drops when the nebulizer turns on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD cylinder run time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 28 minutes (Fixed system)\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eAbout 40 minutes at 5 cmH2O, shorter at higher PEEP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure check\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo manometer in the kit. Watch the valve stay open on inspiration; add an in-line gauge, 0 to 30 cmH2O, per protocol.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eBuilt-in color-coded manometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePatients\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdults over 30 kg\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eAdult and child mask sizes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeed a CPAP that runs from a flowmeter? Pulmodyne's \u003ca href=\"\/products\/go-pap\"\u003eGO-PAP disposable emergency CPAP\u003c\/a\u003e runs on a fixed 10 LPM from a metered oxygen supply, about 40 minutes per D cylinder, with PEEP set at 5, 7.5 or 10 cmH2O on the generator.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-15\"\u003e15\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\n\u003cp\u003eReplacing a flow-set disposable CPAP? Check the oxygen supply first: the O2-MAX connects to a 50 psi outlet, not a flowmeter, and PEEP moves from the flowmeter to the valve, so crews choose a valve setting instead of reading a flow-to-PEEP chart.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-9\"\u003e9\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\n\u003ch2\u003eWho Uses This:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMS Agencies and Fire Departments:\u003c\/strong\u003e high flow for severe respiratory distress,\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-11\"\u003e11\u003c\/a\u003e\u003c\/sup\u003e PEEP chosen with the valve, nebulizer systems for in-line treatments, and filtered exhalation in the patient compartment.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e Compare all \u003ca href=\"\/collections\/cpap-circuits\"\u003edisposable EMS CPAP devices\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMTs, Paramedics and BLS Crews:\u003c\/strong\u003e PEEP is a valve setting rather than a flow calculation,\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-9\"\u003e9\u003c\/a\u003e\u003c\/sup\u003e for agencies whose scope and protocols include CPAP at the EMT, AEMT or paramedic level.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-16\"\u003e16\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmergency Departments and Hospitals:\u003c\/strong\u003e labeled for hospital as well as prehospital use. The Quik-Connect plugs into the wall outlet and moves with the patient between rooms and to the ambulance.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-5\"\u003e5\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCritical Care and Interfacility Transport:\u003c\/strong\u003e Trio systems set about 30, 60 or 90%+ FiO2 for patients who need more oxygen, with continuous pulse oximetry.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-6\"\u003e6\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/go-pap\"\u003ePulmodyne GO-PAP disposable emergency CPAP (10 LPM flowmeter CPAP)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/gt-284ma-15ly1\"\u003eGentec click-style oxygen regulator with 50 psi DISS outlet, CGA 870 (284MA-15LY1)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pi-313-111111\"\u003ePulmodyne Quik-Connect, Ohmeda male DISS, case of 30 (313-111111)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pi-313-7029\"\u003eBiTrac ED replacement mask, adult medium (313-7029)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pi-313-7030\"\u003eBiTrac ED replacement mask, adult large (313-7030)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/al-4msf1-7-6-25\"\u003eAirLife adult EtCO2\/O2 filtered divided sampling cannula, box of 25\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/cpap-circuits\"\u003eDisposable CPAP circuits and EMS CPAP devices\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/oxygen-regulators\"\u003eOxygen regulators\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Guides and Documents:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.pulmodyne.com\/wp-content\/uploads\/2021\/09\/2764-o2-max-fixed-system-with-nebulizer.pdf\" rel=\"noopener\" target=\"_blank\"\u003eO2-MAX Fixed System with Nebulizer, Directions for Use (2764G, PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.pulmodyne.com\/wp-content\/uploads\/2021\/09\/3512-o2-max-fixed-system.pdf\" rel=\"noopener\" target=\"_blank\"\u003eO2-MAX Fixed System without nebulizer, Directions for Use (3512G, PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.pulmodyne.com\/wp-content\/uploads\/2021\/09\/2260-o2-max-trio-system.pdf\" rel=\"noopener\" target=\"_blank\"\u003eO2-MAX Trio System, Directions for Use (2260F, PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.pulmodyne.com\/wp-content\/uploads\/2021\/09\/3076-o2-max-guard-filter-standalone.pdf\" rel=\"noopener\" target=\"_blank\"\u003eO2-MAX Guard exhalation filter, Directions for Use (3076C, PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.pulmodyne.com\/wp-content\/uploads\/2021\/08\/O2-MAX-Brochure.pdf\" rel=\"noopener\" target=\"_blank\"\u003eO2-MAX brochure and ordering guide (2812H, PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.pulmodyne.com\/wp-content\/uploads\/2022\/11\/5805PROMO.pdf\" rel=\"noopener\" target=\"_blank\"\u003ePulmodyne accessories brochure with PEEP valve part numbers (5805E, PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.pulmodyne.com\/wp-content\/uploads\/2022\/08\/qc-8292.pdf\" rel=\"noopener\" target=\"_blank\"\u003eQuik-Connect disposable DISS fittings (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003ePulmodyne's O2-MAX overview video is in the gallery above.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions:\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat is the Pulmodyne O2-MAX CPAP and how does it work?\u003c\/summary\u003e\u003cp\u003eThe Pulmodyne O2-MAX (also written O2 MAX, 02 MAX or 02-MAX) is a disposable fixed-flow venturi CPAP. Oxygen from a 50 psi source drives the generator, which entrains room air and delivers up to 140 LPM to the mask at about 30% FiO2. An O2-CPAP valve on the circuit holds PEEP through inspiration and exhalation, independent of the patient's flow rate, and filters clean the air in both directions.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat oxygen supply does the O2-MAX need?\u003c\/summary\u003e\u003cp\u003eA 50 psi (about 4 bar) oxygen source. Connect the O2-MAX directly to a 50 psi outlet: an ambulance or hospital wall outlet, or a cylinder regulator with a 50 psi DISS outlet, such as the \u003ca href=\"\/products\/gt-284ma-15ly1\"\u003eGentec 284MA-15LY1\u003c\/a\u003e. It does not run from a flowmeter barb. Use oxygen only, and disconnect it from the source when not in use.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-4\"\u003e4\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhich oxygen fitting does the O2-MAX need: DISS or Quik-Connect?\u003c\/summary\u003e\u003cp\u003eIt depends on the outlet. For an Ohmeda wall outlet, choose a -1 part number, which comes with the Ohmeda Quik-Connect attached. For a cylinder regulator with a 50 psi DISS outlet, choose a part number without -1. For a Chemetron, Puritan Bennett or Schrader wall outlet, choose a part number without -1 and add the matching Quik-Connect: 313-121111, 313-131111 or 313-141111. Every O2-MAX needs a 50 psi source, not a flowmeter.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-5\"\u003e5\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eHow long does a D cylinder last on the O2-MAX?\u003c\/summary\u003e\u003cp\u003eUp to 28 minutes of run time on a D cylinder with a Fixed system.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e Run time at the Trio 60% and 90% settings is not specified. For longer transports, run the O2-MAX from the vehicle's main oxygen supply through a 50 psi wall outlet: -1 systems plug into Ohmeda-type outlets, and other outlet types take the matching Quik-Connect (nine types are made).\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-5\"\u003e5\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eHow many LPM and what FiO2 does the O2-MAX CPAP deliver?\u003c\/summary\u003e\u003cp\u003eUp to 140 LPM to the patient at about 30% FiO2 on Fixed systems, from a 50 psi oxygen source. There is no flowmeter setting and no flow-to-PEEP chart: the valve sets PEEP, which holds at flows from 60 to 140 LPM.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e Trio systems, or a Fixed generator with the Trio control unit (313-8000), deliver about 30, 60 or 90%+: turn the knob until the setting is fully visible in the window, or about 30% is delivered. Monitor SpO2, and use an oxygen analyzer for an exact FiO2.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-6\"\u003e6\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-8\"\u003e8\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eHow do I set PEEP on the O2-MAX?\u003c\/summary\u003e\u003cp\u003ePEEP is set with the valve on the circuit, not the flowmeter. Twist the top of the white 3-SET valve to 5, 7.5 or 10 cmH2O; the gray 5-SET valve covers 5, 7.5, 10, 12.5 and 15 cmH2O; fixed valves are color coded from 2.5 to 20 cmH2O. Watch that the valve stays open during inspiration, and set PEEP per local protocol.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-9\"\u003e9\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e With the pre-attached Guard filter, PEEP runs about 1.5 cmH2O above the valve setting.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I give albuterol through the O2-MAX for reactive airway, asthma or COPD patients?\u003c\/summary\u003e\u003cp\u003eYes, with an N system, when protocol calls for an in-line bronchodilator in reactive airway disease. Push the nebulizer canister into the nebulizer port with a quarter turn, set the gas flow and check for mist. The filter sits before the nebulizer port, so it saturates with medication less than an in-line filter would.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e NASEMSO guidelines advise giving bronchodilators in line with NIV when indicated.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-11\"\u003e11\u003c\/a\u003e\u003c\/sup\u003e CPAP evidence in asthma is limited,\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-17\"\u003e17\u003c\/a\u003e\u003c\/sup\u003e and guidelines favor bilevel NIV for acidotic COPD,\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-18\"\u003e18\u003c\/a\u003e\u003c\/sup\u003e so follow local protocol.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eDoes the O2-MAX filter exhaled air, and how often is the filter changed?\u003c\/summary\u003e\u003cp\u003eYes. The O2-MAX Guard exhalation filter comes pre-attached and the generator has an inhalation filter, so air is filtered in both directions; filter efficiency is more than 99.99% bacterial and viral.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e Replace the Guard filter at least every 24 hours, or sooner if resistance rises; the standalone Guard filter is part number 313-8300.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-10\"\u003e10\u003c\/a\u003e\u003c\/sup\u003e With the filter attached, PEEP runs about 1.5 cmH2O above the valve setting and maximum flow is lower than the 140 LPM rating, so confirm delivered pressure on an in-line manometer per protocol.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eCan EMTs, paramedics and BLS crews use the O2-MAX CPAP?\u003c\/summary\u003e\u003cp\u003eYes, when trained and within protocol. The O2-MAX is labeled for thoroughly trained personnel in hospital and prehospital (EMS) care.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e The 2019 National EMS Scope of Practice Model lists CPAP at the EMT, AEMT and paramedic levels, and each state sets its own scope and agency protocol.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-16\"\u003e16\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eIs prehospital CPAP used for congestive heart failure (CHF) and pulmonary edema?\u003c\/summary\u003e\u003cp\u003eYes. ERS\/ATS guidelines recommend CPAP or bilevel NIV for cardiogenic pulmonary edema and suggest it in the prehospital setting.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-18\"\u003e18\u003c\/a\u003e\u003c\/sup\u003e A 2019 Cochrane review of 24 trials, in emergency department and inpatient settings, found that CPAP or bilevel NPPV probably reduced intubation (risk ratio 0.49, moderate certainty).\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-19\"\u003e19\u003c\/a\u003e\u003c\/sup\u003e Choose and titrate PEEP per local protocol.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat are the contraindications for the O2-MAX CPAP?\u003c\/summary\u003e\u003cp\u003eThe O2-MAX may be contraindicated with facial lacerations, laryngeal trauma, recent tracheal or esophageal anastomosis, gastrointestinal bleeding or ileus, recent gastric surgery, basilar skull fracture, high risk of vomiting, emphysematous bulla or hypovolemia. It is for spontaneously breathing adults over 30 kg. With no oxygen flow from the generator, remove the mask.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eIs this a genuine Pulmodyne O2-MAX?\u003c\/summary\u003e\u003cp\u003eYes. Pacific Biomedical is an authorized Pulmodyne distributor. Every O2-MAX ships new in its original Pulmodyne packaging.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eHow fast does the O2-MAX ship?\u003c\/summary\u003e\u003cp\u003eMost orders ship within 1 to 2 business days, and current availability shows on each system page. Expedited and overnight shipping are available at checkout.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eHow do I order the O2-MAX or request a quote?\u003c\/summary\u003e\u003cp\u003eSelect Shop beside a part number in the system chart to open its page and add it to your cart. For a part marked Quote, use that link, or contact \u003ca href=\"mailto:CustomerService@pacificbiomedical.com\"\u003eCustomerService@pacificbiomedical.com\u003c\/a\u003e or 844.436.3526 with the part number. Pacific Biomedical supports net terms for agencies and hospitals and ships to all 50 states.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eReferences\u003c\/summary\u003e\u003cdiv class=\"pbm-refs\"\u003e\u003col\u003e\n\u003cli id=\"ref-1\"\u003ePulmodyne Inc. O2-MAX Fixed System With Nebulizer, Directions for Use, 2764G (2022). \u003ca href=\"https:\/\/www.pulmodyne.com\/wp-content\/uploads\/2021\/09\/2764-o2-max-fixed-system-with-nebulizer.pdf\" rel=\"noopener\" target=\"_blank\"\u003epulmodyne.com\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli id=\"ref-2\"\u003ePulmodyne Inc. O2-MAX Disposable CPAP Device brochure and ordering guide, 2812H (2022). \u003ca href=\"https:\/\/www.pulmodyne.com\/wp-content\/uploads\/2021\/08\/O2-MAX-Brochure.pdf\" rel=\"noopener\" target=\"_blank\"\u003epulmodyne.com\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli id=\"ref-3\"\u003ePulmodyne Inc. O2-MAX Frequently Asked Questions (filter, nebulizer, part numbers).\u003c\/li\u003e\n\u003cli id=\"ref-4\"\u003eGenStar Technologies. Gentec 284 and 285 Series click-style oxygen regulators, specifications (DISS outlet models, 50 psi delivery pressure). \u003ca href=\"https:\/\/www.genstartech.com\/click-style-regulator-hose-barb-outlet\" rel=\"noopener\" target=\"_blank\"\u003egenstartech.com\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli id=\"ref-5\"\u003ePulmodyne Inc. Quik-Connect disposable DISS gas fittings, qc-8292. \u003ca href=\"https:\/\/www.pulmodyne.com\/wp-content\/uploads\/2022\/08\/qc-8292.pdf\" rel=\"noopener\" target=\"_blank\"\u003epulmodyne.com\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli id=\"ref-6\"\u003ePulmodyne Inc. O2-MAX Trio System, Directions for Use, 2260F (2022). \u003ca href=\"https:\/\/www.pulmodyne.com\/wp-content\/uploads\/2021\/09\/2260-o2-max-trio-system.pdf\" rel=\"noopener\" target=\"_blank\"\u003epulmodyne.com\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli id=\"ref-7\"\u003ePulmodyne Inc. O2-MAX Trio Control Unit, Directions for Use, 2261D (2022). \u003ca href=\"https:\/\/www.pulmodyne.com\/wp-content\/uploads\/2021\/09\/2261-o2-max-trio-control-unit.pdf\" rel=\"noopener\" target=\"_blank\"\u003epulmodyne.com\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli id=\"ref-8\"\u003ePulmodyne Inc. O2-MAX Fixed System, Directions for Use, 3512G (2022). \u003ca href=\"https:\/\/www.pulmodyne.com\/wp-content\/uploads\/2021\/09\/3512-o2-max-fixed-system.pdf\" rel=\"noopener\" target=\"_blank\"\u003epulmodyne.com\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli id=\"ref-9\"\u003ePulmodyne Inc. O2-MAX product page (PEEP valves, Quik-Connects, Omni Clip, part list). \u003ca href=\"https:\/\/www.pulmodyne.com\/product\/o2-max\" rel=\"noopener\" target=\"_blank\"\u003epulmodyne.com\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli id=\"ref-10\"\u003ePulmodyne Inc. O2-MAX Guard Filter, Directions for Use, 3076C. \u003ca href=\"https:\/\/www.pulmodyne.com\/wp-content\/uploads\/2021\/09\/3076-o2-max-guard-filter-standalone.pdf\" rel=\"noopener\" target=\"_blank\"\u003epulmodyne.com\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli id=\"ref-11\"\u003eNational Association of State EMS Officials. National Model EMS Clinical Guidelines, Version 3.0 (2022), Respiratory Distress: NIV by CPAP, bronchodilators in line with NIV, pulse oximetry and EtCO2. \u003ca href=\"https:\/\/nasemso.org\/content.aspx?page_id=22\u0026amp;club_id=157064\u0026amp;module_id=701974\" rel=\"noopener\" target=\"_blank\"\u003enasemso.org\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli id=\"ref-12\"\u003ePulmodyne Inc. O2-CPAP Valve, Directions for Use, 3645. \u003ca href=\"https:\/\/www.pulmodyne.com\/wp-content\/uploads\/2021\/12\/3645-o2-cpap-valve.pdf\" rel=\"noopener\" target=\"_blank\"\u003epulmodyne.com\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli id=\"ref-13\"\u003ePulmodyne Inc. Accessories brochure (O2-CPAP and 3-SET\/5-SET PEEP valves), 5805E (2022). \u003ca href=\"https:\/\/www.pulmodyne.com\/wp-content\/uploads\/2022\/11\/5805PROMO.pdf\" rel=\"noopener\" target=\"_blank\"\u003epulmodyne.com\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli id=\"ref-14\"\u003eU.S. Food and Drug Administration. AccessGUDID device records, brand O2-MAX and O2-CPAP, Pulmodyne Inc. (product code BYE, single use, GTINs). \u003ca href=\"https:\/\/accessgudid.nlm.nih.gov\/devices\/search?query=O2-MAX\" rel=\"noopener\" target=\"_blank\"\u003eaccessgudid.nlm.nih.gov\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli id=\"ref-15\"\u003ePulmodyne Inc. GO-PAP Disposable CPAP Device brochure and ordering guide, 2503F (2022). \u003ca href=\"https:\/\/www.pulmodyne.com\/wp-content\/uploads\/2021\/08\/GO-PAP-Brochure.pdf\" rel=\"noopener\" target=\"_blank\"\u003epulmodyne.com\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli id=\"ref-16\"\u003eNational Highway Traffic Safety Administration. National EMS Scope of Practice Model 2019 (CPAP at the EMT, AEMT and paramedic levels). \u003ca href=\"https:\/\/www.ems.gov\/assets\/National_EMS_Scope_of_Practice_Model_2019.pdf\" rel=\"noopener\" target=\"_blank\"\u003eems.gov\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli id=\"ref-17\"\u003eLim WJ, Mohammed Akram R, Carson KV, et al. Non-invasive positive pressure ventilation for treatment of respiratory failure due to severe acute exacerbations of asthma. Cochrane Database Syst Rev. 2012;12:CD004360. \u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/23235608\/\" rel=\"noopener\" target=\"_blank\"\u003epubmed.ncbi.nlm.nih.gov\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli id=\"ref-18\"\u003eRochwerg B, Brochard L, Elliott MW, et al. Official ERS\/ATS clinical practice guidelines: noninvasive ventilation for acute respiratory failure. Eur Respir J. 2017;50(2):1602426. \u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/28860265\/\" rel=\"noopener\" target=\"_blank\"\u003epubmed.ncbi.nlm.nih.gov\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli id=\"ref-19\"\u003eBerbenetz N, Wang Y, Brown J, et al. Non-invasive positive pressure ventilation (CPAP or bilevel NPPV) for cardiogenic pulmonary oedema. Cochrane Database Syst Rev. 2019;4:CD005351. \u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/30950507\/\" rel=\"noopener\" target=\"_blank\"\u003epubmed.ncbi.nlm.nih.gov\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ol\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n","brand":"Pulmodyne Inc.","offers":[{"title":"Default Title","offer_id":49256844263735,"sku":"0016","price":70.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/7415\/6599\/files\/O2-MAX_DisposableCPAPSystem.webp?v=1770654433","url":"https:\/\/shop.pacificbiomedical.com\/products\/o2-max","provider":"Pacific Biomedical","version":"1.0","type":"link"}