{"product_id":"nomoline-lh-adt-ped-arwy-adpt-set-25-box","title":"NOMOLINE LH ADT\/PED ARWY ADPT SET,25\/BOX","description":"\u003cstyle\u003e\n    .pbm-product{--pbm-blue:#1E4C8A;--pbm-accent:#2563EB;--pbm-surface:#EFF6FF;--pbm-border:#CBD5E1;--pbm-text:#1F2937;--pbm-text2:#334155;color:var(--pbm-text);font-family:-apple-system,BlinkMacSystemFont,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;line-height:1.6;max-width:900px;margin:0 auto;overflow-wrap:break-word;}\n    .pbm-product h2{color:var(--pbm-blue);font-size:1.35rem;margin:2rem 0 .75rem;padding-bottom:.4rem;border-bottom:2px solid var(--pbm-surface);text-align:center;}\n    .pbm-product h3{color:var(--pbm-blue);font-size:1.05rem;margin:.25rem 0 .4rem;}\n    .pbm-product p{margin:.6rem 0;color:var(--pbm-text2);}\n    .pbm-product a{color:var(--pbm-accent);text-decoration:none;font-weight:600;}\n    .pbm-product a:hover{text-decoration:underline;}\n    .pbm-lead{background:var(--pbm-surface);border:1px solid var(--pbm-border);border-radius:10px;padding:1.25rem 1.5rem;margin-bottom:1.25rem;}\n    .pbm-lead p{color:var(--pbm-text);font-size:1.02rem;margin:0;}\n    .pbm-facts{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:.6rem;margin:1.25rem 0;}\n    @media (max-width:640px){.pbm-product .pbm-facts{grid-template-columns:repeat(2,minmax(0,1fr));}}\n    @media (max-width:400px){.pbm-product .pbm-facts{grid-template-columns:minmax(0,1fr);}}\n    .pbm-fact{background:var(--pbm-surface);border:1px solid var(--pbm-border);border-radius:8px;padding:.75rem .85rem;text-align:center;min-width:0;overflow-wrap:break-word;}\n    .pbm-product .pbm-fact-label{display:block;font-size:.7rem;font-weight:600;letter-spacing:.07em;text-transform:uppercase;color:var(--pbm-text2);margin-bottom:.3rem;}\n    .pbm-product .pbm-fact-value{display:block;font-size:.92rem;font-weight:600;color:var(--pbm-blue);line-height:1.35;}\n    .pbm-product .pbm-highlights{list-style:none !important;padding-left:0 !important;margin:.5rem 0;}\n    .pbm-product .pbm-highlights li{list-style:none !important;position:relative;padding:.5rem 0 .5rem 1.5rem;border-bottom:1px solid var(--pbm-surface);color:var(--pbm-text2);}\n    .pbm-product .pbm-highlights li::marker{content:\"\";}\n    .pbm-product .pbm-highlights li:before{content:\"\";position:absolute;left:0;top:.95rem;width:8px;height:8px;border-radius:50%;background:var(--pbm-accent);}\n    .pbm-clinical{background:#fff;border:1px solid var(--pbm-border);border-left:4px solid var(--pbm-accent);border-radius:8px;padding:1rem 1.25rem;margin:1.25rem 0;}\n    .pbm-clinical h3{margin-top:0;}\n    .pbm-clinical p{font-size:.95rem;}\n    .pbm-cite{font-size:.7em;vertical-align:super;line-height:0;}\n    .pbm-product .pbm-cite a{color:var(--pbm-accent);font-weight:600;text-decoration:none;}\n    .pbm-refs{background:#fff;border:1px solid var(--pbm-border);border-radius:10px;padding:1rem 1.25rem;margin:1.25rem 0;}\n    .pbm-refs h3{margin-top:0;text-align:center;}\n    .pbm-refs ol{margin:.5rem 0 0;padding-left:1.4rem;}\n    .pbm-refs li{font-size:.85rem;color:var(--pbm-text2);margin-bottom:.55rem;line-height:1.5;}\n    .pbm-refs .pbm-refnote{font-size:.8rem;color:var(--pbm-text2);margin-top:.85rem;}\n    .pbm-table{width:100%;border-collapse:collapse;margin:.75rem 0;font-size:.92rem;}\n    .pbm-table th,.pbm-table td{border:1px solid var(--pbm-border);padding:.6rem .8rem;text-align:left;word-break:break-word;}\n    .pbm-product .pbm-table th{background:var(--pbm-blue) !important;color:#ffffff !important;font-weight:600;}\n    .pbm-product .pbm-table th *{color:#ffffff !important;}\n    .pbm-table tr:nth-child(even) td{background:var(--pbm-surface);}\n    .pbm-table td:first-child{font-weight:600;color:var(--pbm-blue);width:38%;}\n    .pbm-compat{background:var(--pbm-surface);border:1px solid var(--pbm-border);border-radius:10px;padding:1.1rem 1.35rem;margin:1rem 0;}\n    .pbm-compat h3{margin-top:0;text-align:center;}\n    .pbm-product .pbm-compat ul{list-style:none !important;padding-left:0 !important;margin:.5rem 0 0;}\n    .pbm-product .pbm-compat li::marker{content:\"\";}\n    .pbm-compat li{padding:.5rem 0;border-bottom:1px solid #fff;}\n    .pbm-compat li:last-child{border-bottom:none;}\n    .pbm-cards{display:grid;grid-template-columns:repeat(auto-fit,minmax(190px,1fr));gap:1rem;margin:.75rem 0;}\n    .pbm-card{background:#fff;border:1px solid var(--pbm-border);border-top:3px solid var(--pbm-accent);border-radius:10px;padding:1rem 1.1rem;}\n    .pbm-card h3{margin-top:0;font-size:1rem;}\n    .pbm-card p{font-size:.9rem;margin:.35rem 0 0;}\n    .pbm-faq details{border:1px solid var(--pbm-border);border-radius:8px;margin:.5rem 0;overflow:hidden;background:#fff;}\n    .pbm-product .pbm-faq summary{cursor:pointer;padding:.85rem 1.1rem;font-weight:600;color:var(--pbm-blue);background:var(--pbm-surface);list-style:none !important;}\n    .pbm-product .pbm-faq summary::marker{content:\"\";}\n    .pbm-faq summary::-webkit-details-marker{display:none;}\n    .pbm-faq summary:after{content:\"+\";float:right;color:var(--pbm-accent);font-weight:700;}\n    .pbm-faq details[open] summary:after{content:\"\\2013\";}\n    .pbm-faq .pbm-answer{padding:.85rem 1.1rem;color:var(--pbm-text2);font-size:.94rem;}\n    .pbm-reg{background:#fff;border:1px solid var(--pbm-border);border-radius:10px;padding:1rem 1.25rem;margin:1.25rem 0;}\n    .pbm-reg .pbm-trust{color:var(--pbm-blue);font-size:.95rem;margin:0 0 .5rem;}\n    .pbm-order{background:var(--pbm-blue);border-radius:10px;padding:1.25rem 1.5rem;margin-top:1.5rem;text-align:center;}\n    .pbm-product .pbm-order,.pbm-product .pbm-order h3,.pbm-product .pbm-order p,.pbm-product .pbm-order a,.pbm-product .pbm-order strong{color:#ffffff !important;}\n    .pbm-order p{margin:.35rem 0;}\n    .pbm-order a{text-decoration:underline;}\n    .pbm-order .pbm-phone{font-size:1.25rem;font-weight:700;}\n  \n.pbm-collapsible{border:1px solid var(--pbm-border);border-radius:10px;margin:1.25rem 0;overflow:hidden;background:#fff;}\n.pbm-product .pbm-collapsible\u003esummary{cursor:pointer;padding:.85rem 1.1rem;font-weight:600;font-size:1.1rem;color:var(--pbm-blue);background:var(--pbm-surface);list-style:none !important;}\n.pbm-product .pbm-collapsible\u003esummary::marker{content:\"\";}\n.pbm-collapsible\u003esummary::-webkit-details-marker{display:none;}\n.pbm-collapsible\u003esummary:after{content:\"+\";float:right;color:var(--pbm-accent);font-weight:700;}\n.pbm-collapsible[open]\u003esummary:after{content:\"\\2013\";}\n.pbm-collapsible\u003e.pbm-faq{margin:.5rem 1rem 1rem;padding:0;}\n.pbm-collapsible\u003e.pbm-refs{margin:0;border:none;border-radius:0;padding:1rem 1.25rem 1.1rem;}\n\u003c\/style\u003e\n\u003cdiv class=\"pbm-product\"\u003e\n\u003c!-- 1. LEAD OVERVIEW --\u003e\n\u003cdiv class=\"pbm-lead\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eMasimo NomoLine LH Adult\/Pediatric Airway Adapter Set\u003c\/strong\u003e (item 3814, 6.6 foot line, 25 per box) is the sidestream capnography consumable for an \u003cstrong\u003eintubated\u003c\/strong\u003e adult or pediatric patient.  Compatible with the \u003cstrong\u003eZOLL Zenix\u003c\/strong\u003e, item 8000-010115, \"ADULT\/PEDIATRIC NOMOLINE LH AIRWAY ADAPTER SET (BOX OF 25) REF 3814\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- 2. AT-A-GLANCE SPEC GRID --\u003e\n\u003cdiv class=\"pbm-facts\"\u003e\n\u003cdiv class=\"pbm-fact\"\u003e\n\u003cspan class=\"pbm-fact-label\"\u003eItem Number\u003c\/span\u003e\u003cspan class=\"pbm-fact-value\"\u003e3814\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pbm-fact\"\u003e\n\u003cspan class=\"pbm-fact-label\"\u003ePack\u003c\/span\u003e\u003cspan class=\"pbm-fact-value\"\u003e25 per box\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pbm-fact\"\u003e\n\u003cspan class=\"pbm-fact-label\"\u003eLine Length\u003c\/span\u003e\u003cspan class=\"pbm-fact-value\"\u003e6.6 feet\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pbm-fact\"\u003e\n\u003cspan class=\"pbm-fact-label\"\u003ePatient\u003c\/span\u003e\u003cspan class=\"pbm-fact-value\"\u003eAdult\/pediatric, intubated\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pbm-fact\"\u003e\n\u003cspan class=\"pbm-fact-label\"\u003eDead Space\u003c\/span\u003e\u003cspan class=\"pbm-fact-value\"\u003e6 mL\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pbm-fact\"\u003e\n\u003cspan class=\"pbm-fact-label\"\u003eConnection\u003c\/span\u003e\u003cspan class=\"pbm-fact-value\"\u003eDirect to ISA inlet\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- 3. PRODUCT HIGHLIGHTS \/ WHY IT MATTERS --\u003e\n\u003ch2\u003eProduct Highlights\u003c\/h2\u003e\n\u003cul class=\"pbm-highlights\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eZOLL Zenix part.\u003c\/strong\u003e ZOLL sells this set as item 8000-010115, \"Adult\/Pediatric NomoLine LH Airway Adapter Set (Box of 25), REF 3814,\u003cspan class=\"pbm-cite\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul class=\"pbm-highlights\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eDead space 6 mL.\u003c\/strong\u003e Adult and pediatric only. Not for infants or neonates. The infant\/neonatal set is part 4367 at 0.7 mL.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-1\"\u003e1\u003c\/a\u003e,\u003ca href=\"#pbm-ref-3\"\u003e3\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSampling flow 50 plus or minus 10 sml\/min.\u003c\/strong\u003e\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-4\"\u003e4\u003c\/a\u003e\u003c\/span\u003e Accurate from 0 to 150 breaths per minute at that rate.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-5\"\u003e5\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 rise time 200 ms or less\u003c\/strong\u003e at 50 sml\/min; total analyzer system response time under 3 seconds, specified with a 6.6 foot line.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-4\"\u003e4\u003c\/a\u003e,\u003ca href=\"#pbm-ref-5\"\u003e5\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLH class.\u003c\/strong\u003e Collects water; short term applications with low humidity. HH (part 3827) removes aspirated and condensed water for long term applications with high humidity.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-1\"\u003e1\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo water trap.\u003c\/strong\u003e NomoLine no-moisture tubing with an inline hydrophobic bacterial filter.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-1\"\u003e1\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul class=\"pbm-highlights\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle patient use.\u003c\/strong\u003e Maximum 14 days of use. Not made with natural rubber latex. Do not submerge or sterilize by any method.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-1\"\u003e1\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e25 sets per box\u003c\/strong\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- 4. CLINICAL \/ TECHNICAL CONTEXT (E-E-A-T; cited, conservative, IFU line included) --\u003e\n\u003cdiv class=\"pbm-clinical\"\u003e\u003c\/div\u003e\n\u003ch2\u003eSpecifications and Compatibility\u003c\/h2\u003e\n\u003ctable class=\"pbm-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eMasimo Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eItem Number\u003c\/td\u003e\n\u003ctd\u003e3814\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacific Biomedical SKU\u003c\/td\u003e\n\u003ctd\u003eMAS-3814\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eNomoLine LH Adult\/Pediatric Airway Adapter Set\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-9\"\u003e9\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePatient Population\u003c\/td\u003e\n\u003ctd\u003eIntubated adult and pediatric patients. Not for infants or neonates.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-1\"\u003e1\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Class\u003c\/td\u003e\n\u003ctd\u003eLH (low humidity). Collects water; short term applications. HH (part 3827) removes aspirated and condensed water for long term, high humidity use.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-1\"\u003e1\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Line Length\u003c\/td\u003e\n\u003ctd\u003e6.6 feet (2 meters, as the Masimo catalog lists it)\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-9\"\u003e9\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Group\u003c\/td\u003e\n\u003ctd\u003eGroup 2. Connects directly to the ISA gas inlet connector.\u003cspan class=\"pbm-cite\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZOLL Cross-Reference\u003c\/td\u003e\n\u003ctd\u003eZOLL item 8000-010115, \"Adult\/Pediatric NomoLine LH Airway Adapter Set (Box of 25), REF 3814.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-2\"\u003e2\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirway Adapter Dead Space\u003c\/td\u003e\n\u003ctd\u003e6 mL. The infant\/neonatal set (part 4367) is 0.7 mL and is not interchangeable.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-1\"\u003e1\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Flow Rate\u003c\/td\u003e\n\u003ctd\u003e50 plus or minus 10 sml\/min at the ISA analyzer\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-4\"\u003e4\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCO2 Rise Time\u003c\/td\u003e\n\u003ctd\u003e200 ms or less at 50 sml\/min sample flow\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-4\"\u003e4\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Response Time\u003c\/td\u003e\n\u003ctd\u003eUnder 3 seconds, specified with a 6.6 foot sampling line\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-5\"\u003e5\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRespiratory Rate Range\u003c\/td\u003e\n\u003ctd\u003eAccurate from 0 to 150 breaths per minute at a 50 mL\/min sampling rate.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-5\"\u003e5\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Placement\u003c\/td\u003e\n\u003ctd\u003eSmall diameter end to the Y-piece of the ventilation source, large end to the endotracheal tube.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-1\"\u003e1\u003c\/a\u003e\u003c\/span\u003e Position between the elbow and the ventilator circuit wye, not between the ET tube and the elbow; sampling tube exits the top.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-3\"\u003e3\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoisture Handling\u003c\/td\u003e\n\u003ctd\u003eNomoLine no-moisture tubing with an inline hydrophobic bacterial filter. No water trap required.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-1\"\u003e1\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReuse\u003c\/td\u003e\n\u003ctd\u003eSingle patient use. Do not re-use; cross contamination risk.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-1\"\u003e1\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCleaning and Sterilization\u003c\/td\u003e\n\u003ctd\u003eDo not submerge in any cleaning solution or attempt to sterilize by autoclave, irradiation, steam, gas, ethylene oxide, or any other method.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-1\"\u003e1\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Use Time\u003c\/td\u003e\n\u003ctd\u003eReplace for each new patient with a maximum of 14 days of use. Masimo's own footnote: the lifetime of the product depends on the application and product type.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-1\"\u003e1\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLatex\u003c\/td\u003e\n\u003ctd\u003eNot made with natural rubber latex\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-1\"\u003e1\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegulatory Status\u003c\/td\u003e\n\u003ctd\u003ePrescription device. See the Regulatory and Shipping section below.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack Size\u003c\/td\u003e\n\u003ctd\u003e25 per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelated Part Numbers\u003c\/td\u003e\n\u003ctd\u003e4620 same set on a 13.1 foot line; 3827 HH adult\/pediatric 6.6 ft; 4367 HH infant\/neonatal 6.6 ft; 3820 adult nasal cannula with O2 for non-intubated patients\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-9\"\u003e9\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterility\u003c\/td\u003e\n\u003ctd\u003eNot stated in the manufacturer's directions for use. Contact us if you need a written statement from Masimo for a bid or an infection control file, and we will get one rather than repeat something we cannot stand behind.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- 6. COMPLETE-THE-SYSTEM \/ INTERNAL LINKING (capnography consumables cluster) --\u003e\n\u003cdiv class=\"pbm-compat\"\u003e\n\u003ch3\u003eComplete the Capnography Setup\u003c\/h3\u003e\n\u003cp\u003eThis set covers the intubated adult or pediatric patient on a Masimo ISA analyzer. Here is what Pacific Biomedical carries around it, with the honest note on where each one fits.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSame range, patient breathing on their own:\u003c\/strong\u003e \u003ca href=\"\/products\/nomoline-lh-adult-nasal-co2-cannula-with-o2-25-box\"\u003eNomoLine LH Adult Nasal CO2 Cannula with O2, 25\/box (3820)\u003c\/a\u003e. Also a Group 2 direct-connect line, so it uses the same inlet. Swap the adapter set for the cannula when the patient is not tubed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMainstream instead of sidestream:\u003c\/strong\u003e \u003ca href=\"\/products\/mas-9632\"\u003eMasimo 9632 EMMA Capnometer Kit\u003c\/a\u003e with its \u003ca href=\"\/products\/masimo-emma-airway-adapter\"\u003eEMMA Airway Adapters\u003c\/a\u003e. EMMA measures in the airway with its own adapter and no sampling line at all. A useful standalone for a rig with no capnography head on the monitor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntubated patient on a non-Masimo sampling system:\u003c\/strong\u003e \u003ca href=\"\/products\/airlife-4msf5-6-25\"\u003eAirLife Adult\/Pediatric Filtered EtCO2 Line with ETT Adapter, 6 ft\u003c\/a\u003e. Use the line your monitor manufacturer specifies and do not mix brands on one analyzer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygenation on the same patient:\u003c\/strong\u003e \u003ca href=\"\/products\/masimo-1863\"\u003eMasimo 1863 LNCS DCI Adult SpO2 Sensor\u003c\/a\u003e. Ventilation and oxygenation answer different questions, which is really what the clinical section above is about.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- 7. WHAT'S INCLUDED --\u003e\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul class=\"pbm-highlights\"\u003e\n\u003cli\u003e25 Masimo NomoLine LH Adult\/Pediatric Airway Adapter Sets (item 3814)\u003c\/li\u003e\n\u003cli\u003eEach set is a single-patient-use airway adapter with an integrated 6.6 foot NomoLine sampling line, an inline hydrophobic bacterial filter, and a direct ISA gas inlet connector\u003c\/li\u003e\n\u003cli\u003eNo water trap, no multi-patient adapter, and no separate filter to buy\u003c\/li\u003e\n\u003cli\u003eNo oxygen tubing. This is an airway adapter set for intubated patients, not a cannula, and several competing listings confuse the two\u003c\/li\u003e\n\u003cli\u003eThe 13.1 foot version (4620), the HH version (3827), and the infant\/neonatal set (4367) are made by Masimo. Contact us and we will quote them.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- 8. WHO USES THIS --\u003e\n\u003ch2\u003eWho Uses This\u003c\/h2\u003e\n\u003cdiv class=\"pbm-cards\"\u003e\n\u003cdiv class=\"pbm-card\"\u003e\n\u003ch3\u003eGround EMS \u0026amp; Ambulance\u003c\/h3\u003e\n\u003cp\u003ePost-intubation transports and working arrests on a Zenix or another ISA-equipped monitor, where the waveform is the only continuous proof the tube has not moved.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pbm-card\"\u003e\n\u003ch3\u003eCritical Care \u0026amp; Interfacility Transport\u003c\/h3\u003e\n\u003cp\u003eLong ventilated moves where nobody wants to service a water trap or swap a fouled line in the back of a truck.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pbm-card\"\u003e\n\u003ch3\u003eEmergency Department \u0026amp; Resuscitation\u003c\/h3\u003e\n\u003cp\u003eAirway bay and code cart stock, on the analyzer already in the room, with the adapter set that plugs straight into the inlet.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pbm-card\"\u003e\n\u003ch3\u003eBiomed \u0026amp; Materials Management\u003c\/h3\u003e\n\u003cp\u003eOne standard consumable across a Masimo ISA fleet, on a part number with published dead space, flow, and response time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- 9. FAQ (harvested questions + authenticity\/shipping\/ordering trio) --\u003e\n\u003cdetails class=\"pbm-collapsible\"\u003e\n\u003csummary\u003eFrequently Asked Questions\u003c\/summary\u003e\n\u003cdiv class=\"pbm-faq\"\u003e\n\u003cdetails\u003e\n\u003csummary\u003eLH or HH, which airway adapter set should I order?\u003c\/summary\u003e\n\u003cdiv class=\"pbm-answer\"\u003eMasimo's directions for use define it plainly: LH collects water and is for short term applications with low humidity; HH removes aspirated and condensed water and is for long term applications with high humidity. It describes the duty cycle and the gas you are sampling, not the climate of the room. Item 3814 is the LH adult\/pediatric set. The HH equivalent is 3827.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-1\"\u003e1\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes 3814 plug straight into the analyzer, or do I need the 3800 adapter?\u003c\/summary\u003e\n\u003cdiv class=\"pbm-answer\"\u003eStraight in. Masimo splits the range into two groups. Group 1 lines, 3801 through 3813 and 4368, connect through the NomoLine HH Multi-Patient Use Adapter 3800. Group 2 lines, 3814 through 3839 plus 4367 and 4369, are intended to connect directly to the ISA gas inlet connector. 3814 is Group 2, so nothing goes in between.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-1\"\u003e1\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs this the right part for a ZOLL Zenix, and what else does it fit?\u003c\/summary\u003e\n\u003cdiv class=\"pbm-answer\"\u003eYes. ZOLL's own webstore sells this set as item 8000-010115 against REF 3814, listed under Zenix,\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-2\"\u003e2\u003c\/a\u003e\u003c\/span\u003e and the Zenix operator's guide instructs users to use only Masimo CO2 sampling lines.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-3\"\u003e3\u003c\/a\u003e\u003c\/span\u003e It also fits Masimo ISA gas analyzers and the platforms built on them, including Rad-97, Root, and Radical-7.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-9\"\u003e9\u003c\/a\u003e\u003c\/span\u003e Confirm against your device manual before standardizing.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhere exactly does the airway adapter go in the circuit?\u003c\/summary\u003e\n\u003cdiv class=\"pbm-answer\"\u003eMasimo says connect the small diameter end to the Y-piece of the ventilation source and the large diameter end to the endotracheal tube.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-1\"\u003e1\u003c\/a\u003e\u003c\/span\u003e ZOLL is more specific: put it between the elbow and the ventilator circuit wye, not between the ET tube and the elbow, because that lets secretions collect in the adapter. Keep the sampling tube exiting the top, and verify a proper waveform afterward to confirm the circuit is intact.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-3\"\u003e3\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I use this on an infant, and what is the dead space?\u003c\/summary\u003e\n\u003cdiv class=\"pbm-answer\"\u003eNo. The adult\/pediatric adapter adds 6 mL of dead space to the circuit, and both Masimo and ZOLL state it must not be used on infants or neonates for that reason. The infant and neonatal set is a separate part, 4367, at 0.7 mL, and it must not be run the other way on adults or pediatrics because it can cause excessive flow resistance.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-1\"\u003e1\u003c\/a\u003e,\u003ca href=\"#pbm-ref-3\"\u003e3\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat do I do during nebulized medication or suctioning?\u003c\/summary\u003e\n\u003cdiv class=\"pbm-answer\"\u003eRemove the sampling line connector from the monitor during nebulization or suction on an intubated patient, so moisture does not build up and occlude the line.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-3\"\u003e3\u003c\/a\u003e\u003c\/span\u003e Do not run inhalers or nebulized medications through the set, because it can clog the bacteria filter.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-1\"\u003e1\u003c\/a\u003e\u003c\/span\u003e With a closed suction system, do not place the adapter between the suction catheter and the ET tube.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-3\"\u003e3\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat does a blinking red light at the gas inlet mean, and does this need calibration?\u003c\/summary\u003e\n\u003cdiv class=\"pbm-answer\"\u003eOn the Masimo gas inlet, steady green means monitoring is running, blinking green means zeroing, steady red is a sensor error, and blinking red means check the sampling line for a possible occlusion.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-3\"\u003e3\u003c\/a\u003e\u003c\/span\u003e Replace the line whenever an occlusion alarm fires.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-1\"\u003e1\u003c\/a\u003e\u003c\/span\u003e The spectrometer needs no regular gas zeroing; it takes a room air reference when the line is disconnected.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-3\"\u003e3\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs it single use, and can it be cleaned or sterilized?\u003c\/summary\u003e\n\u003cdiv class=\"pbm-answer\"\u003eSingle patient use, and no. Masimo instructs that the line not be submerged in any cleaning solution or sterilized by autoclave, irradiation, steam, gas, ethylene oxide, or any other method, and not re-used because of cross contamination risk. Replace for each new patient with a maximum of 14 days of use, with Masimo's own caveat that lifetime depends on the application and product type. Not made with natural rubber latex.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-1\"\u003e1\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs this an authentic Masimo product?\u003c\/summary\u003e\n\u003cdiv class=\"pbm-answer\"\u003eYes. Pacific Biomedical supplies genuine, factory-fresh Masimo Corporation products sourced through authorized channels, shipped in original manufacturer packaging.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow fast does this ship?\u003c\/summary\u003e\n\u003cdiv class=\"pbm-answer\"\u003eIn-stock orders typically ship within one business day. For expedited shipping, current lead times, or bulk orders, contact us at \u003ca href=\"mailto:CustomerService@pacificbiomedical.com\"\u003eCustomerService@pacificbiomedical.com\u003c\/a\u003e or 844.436.3526.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow do I place an order, request a quote, or set up an account?\u003c\/summary\u003e\n\u003cdiv class=\"pbm-answer\"\u003eAdd the item to your cart to order online, or contact us for volume pricing, GPO or contract pricing, agency purchase orders, and net terms. Reach us at \u003ca href=\"mailto:CustomerService@pacificbiomedical.com\"\u003eCustomerService@pacificbiomedical.com\u003c\/a\u003e or 844.436.3526.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c!-- 10. REFERENCES (AMA; numbered by order of first appearance) --\u003e\n\u003cdetails class=\"pbm-collapsible\"\u003e\n\u003csummary\u003eReferences\u003c\/summary\u003e\n\u003cdiv class=\"pbm-refs\"\u003e\n\u003col\u003e\n\u003cli id=\"pbm-ref-1\"\u003eMasimo Corporation. NomoLine airway adapter sets and cannulas. Directions for use. LAB-9841A-eIFU. Accessed August 28, 2026. https:\/\/techdocs.masimo.com\/globalassets\/techdocs\/pdf\/lab-9841a-eifu.pdf\u003c\/li\u003e\n\u003cli id=\"pbm-ref-2\"\u003eZOLL Medical Corporation. Masimo NomoLine LH airway adapter set, adult\/pediatric, box of 25. Item 8000-010115. ZOLL Webstore. Accessed August 28, 2026. https:\/\/zollwebstore.com\/defib-and-monitors\/zenix\/ems\/masimo-nomoline-lh-airway-adapter-set-adult-pediatric-box-of-25\u003c\/li\u003e\n\u003cli id=\"pbm-ref-3\"\u003eZOLL Medical Corporation. Zenix EMS operator's guide. 9650-000421-06 Rev. C. Accessed August 28, 2026. https:\/\/www.zoll.com\/products\/defibrillators\u003c\/li\u003e\n\u003cli id=\"pbm-ref-4\"\u003eMasimo Corporation. NomoLine ISA CO2 sidestream gas analyzer operator's manual. LAB-10152A. Accessed August 28, 2026. https:\/\/techdocs.masimo.com\/globalassets\/techdocs\/pdf\/lab-10152a_master.pdf\u003c\/li\u003e\n\u003cli id=\"pbm-ref-5\"\u003eMasimo Corporation. Masimo capnography and multi-gas monitoring. Whitepaper PLM-14382A. Accessed August 28, 2026. https:\/\/www.masimo.com\/siteassets\/us\/documents\/pdf\/plm-14382a-whitepaper-masimo-infrared-spectrometry-global.pdf\u003c\/li\u003e\n\u003cli id=\"pbm-ref-6\"\u003eAlenazi A, Alshibani A. Confirmatory methods for endotracheal tube placement in out-of-hospital settings: a systematic review of the literature. \u003cem\u003eHeliyon\u003c\/em\u003e. 2024;10(7):e28479. doi:10.1016\/j.heliyon.2024.e28479\u003c\/li\u003e\n\u003cli id=\"pbm-ref-7\"\u003eWarner KJ, Cuschieri J, Garland B, et al. The utility of early end-tidal capnography in monitoring ventilation status after severe injury. \u003cem\u003eJ Trauma\u003c\/em\u003e. 2009;66(1):26-31. doi:10.1097\/TA.0b013e3181957a25\u003c\/li\u003e\n\u003cli id=\"pbm-ref-8\"\u003ePaiva EF, Paxton JH, O'Neil BJ. The use of end-tidal carbon dioxide (ETCO2) measurement to guide management of cardiac arrest: a systematic review. \u003cem\u003eResuscitation\u003c\/em\u003e. 2018;123:1-7. doi:10.1016\/j.resuscitation.2017.12.003\u003c\/li\u003e\n\u003cli id=\"pbm-ref-9\"\u003eMasimo Corporation. NomoLine cannulas and airway adapter sets. Accessed August 28, 2026. https:\/\/www.masimo.com\/products\/sensors\/nomoline\/airway-adapters\/\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"pbm-refnote\"\u003ePeer-reviewed citations located via PubMed. This information supports product education and does not replace your agency's protocols, medical direction, or the manufacturer's Instructions for Use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c!-- 11. REGULATORY \u0026 SHIPPING --\u003e\n\u003cdiv class=\"pbm-reg\"\u003e\n\u003cp class=\"pbm-trust\"\u003e\u003cstrong\u003eAuthorized Masimo Distributor (USA).\u003c\/strong\u003e Genuine, factory-fresh product in original manufacturer packaging.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e This legend appears in the NomoLine directions for use and in the NomoLine ISA CO2 operator's manual.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-1\"\u003e1\u003c\/a\u003e,\u003ca href=\"#pbm-ref-3\"\u003e3\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSingle patient use. Not made with natural rubber latex. Do not submerge in cleaning solution or sterilize by any method, and do not apply negative pressure to remove condensed water.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-1\"\u003e1\u003c\/a\u003e\u003c\/span\u003e Do not use sidestream CO2 accessories near flammable anesthetics or other flammable gases, on patients receiving anesthesia, or in an MRI environment, and be aware that a sampling line may ignite in high oxygen concentrations if directly exposed to laser or electrosurgical devices.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-6\"\u003e6\u003c\/a\u003e\u003c\/span\u003e Route the line carefully to reduce the risk of patient entanglement or strangulation, and dispose of used product as biohazardous waste per local regulation.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-1\"\u003e1\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIn-stock orders typically ship within one business day. For current lead times, expedited options, or bulk orders, contact us at \u003ca href=\"mailto:CustomerService@pacificbiomedical.com\"\u003eCustomerService@pacificbiomedical.com\u003c\/a\u003e or 844.436.3526.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- 12. ORDERING CTA --\u003e\n\u003cdiv class=\"pbm-order\"\u003e\n\u003ch3 style=\"margin-top: 0;\"\u003eOrder the Masimo NomoLine LH Adult\/Pediatric Airway Adapter Set, 25\/box\u003c\/h3\u003e\n\u003cp\u003eGenuine Masimo Corporation product, item 3814. Volume, GPO, and agency pricing available.\u003c\/p\u003e\n\u003cp class=\"pbm-phone\"\u003e844.436.3526\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"mailto:CustomerService@pacificbiomedical.com\"\u003eCustomerService@pacificbiomedical.com\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Masimo Corporation","offers":[{"title":"Default Title","offer_id":52912609591607,"sku":"MAS-3814","price":187.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/7415\/6599\/files\/masimo-nomoline-lh-pn3814-airway-adapter-set-both-ends.jpg?v=1790140748","url":"https:\/\/shop.pacificbiomedical.com\/products\/nomoline-lh-adt-ped-arwy-adpt-set-25-box","provider":"Pacific Biomedical","version":"1.0","type":"link"}