{"product_id":"masimo-9794","title":"Masimo Rad-67 9794 Kit, Spot-Check Pulse CO-Oximeter with SpHb","description":"\u003cp\u003eThe Masimo 9794 is the Rad-67 kit: a handheld spot-check Pulse CO-Oximeter that reads functional oxygen saturation (SpO2), pulse rate, perfusion index (Pi), and noninvasive total hemoglobin (SpHb), plus one rainbow M20 patient cable.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e It is a needle-free hemoglobin spot check, not a blood-sample meter, and not a carbon monoxide (SpCO) device.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e The SpHb sensor is not in this kit. Next Generation SpHb on the Rad-67 is available only with a compatible next-generation sensor, the rainbow DCI-mini SC-400 (\u003ca href=\"\/products\/masimo-3798\"\u003eMasimo 3798\u003c\/a\u003e, 400 spot checks).\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-4\"\u003e4\u003c\/a\u003e\u003c\/sup\u003e We are an authorized Masimo distributor and supply the genuine, new Masimo 9794.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's in the Masimo 9794 box\u003c\/h2\u003e\n\u003cp\u003eMasimo's catalog and the dealer quote itemize the kit as the monitor and one patient cable. Sensors must be ordered separately.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e Third-party listings sometimes add an AC adapter or describe the cable as an RD cable. Those descriptions conflict with Masimo's own kit line, so this list marks anything we have not seen on a Masimo packing list as \"confirm.\"\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eIncluded in 9794?\u003c\/th\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRad-67 handheld Pulse CO-Oximeter, with SpO2, pulse rate, perfusion index, and SpHb enabled\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eMasimo catalog 2024 Q3; quote 00575076\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne rainbow M20 patient cable (not an RC cable and not an RD cable)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eQuote 00575076 (\"rainbow M20\"); catalog kit line\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in rechargeable lithium-ion battery\u003c\/td\u003e\n\u003ctd\u003eYes, in the device\u003c\/td\u003e\n\u003ctd\u003eLAB-10262D (up to 6 hours at the lowest indicator brightness with wireless off; about 6 hours to charge)\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003erainbow DCI-mini SpHb sensor (3798 or 3799)\u003c\/td\u003e\n\u003ctd\u003eNo. Order separately.\u003c\/td\u003e\n\u003ctd\u003eCatalog: \"Sensors must be ordered separately.\" Next Generation SpHb is only available with the DCI-mini.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-4\"\u003e4\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMasimo AC power supply \/ adapter\u003c\/td\u003e\n\u003ctd\u003eConfirm\u003c\/td\u003e\n\u003ctd\u003eThe operator's manual lists the AC power supply as part of the Rad-67 system, but the catalog kit line and the quote do not itemize it. Confirm it on the packing list before you depend on it.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhich part number is which: 9794, 9825, 9826, 3798, and 3799\u003c\/h2\u003e\n\u003cp\u003eAuthorized-distributor listings use more than one Rad-67 kit number. They are not interchangeable. We list 9794 and the 3798 sensor separately.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eWhat it is\u003c\/th\u003e\n\u003cth\u003eSensor included?\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e9794\u003c\/td\u003e\n\u003ctd\u003eRad-67 kit: SpO2, pulse rate, perfusion index, SpHb, and one rainbow M20 patient cable. This page.\u003c\/td\u003e\n\u003ctd\u003eNo\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9825\u003c\/td\u003e\n\u003ctd\u003eListed by authorized distributors as a Rad-67 kit that includes a DCI-mini with 200 spot checks (SC-200). Not this page, and not on our 2024 Q3 catalog extract.\u003c\/td\u003e\n\u003ctd\u003eYes, 200 checks, per those listings\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-5\"\u003e5\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9826\u003c\/td\u003e\n\u003ctd\u003eListed as a Rad-67 adult starter kit that includes a DCI-mini with 400 spot checks (SC-400). Not this page.\u003c\/td\u003e\n\u003ctd\u003eYes, 400 checks, per those listings\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-5\"\u003e5\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3798\u003c\/td\u003e\n\u003ctd\u003erainbow DCI-mini SC-400 reusable sensor only, 400 SpHb spot checks. \u003ca href=\"\/products\/masimo-3798\"\u003eQuote-only product page\u003c\/a\u003e.\u003c\/td\u003e\n\u003ctd\u003eThis is the sensor\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-6\"\u003e6\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3799\u003c\/td\u003e\n\u003ctd\u003erainbow DCI-mini, 1,000 spot checks. A different sensor part, not this kit and not our 3798 page.\u003c\/td\u003e\n\u003ctd\u003eThis is the 1,000-check sensor\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-7\"\u003e7\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eSpHb and prehospital blood administration\u003c\/h2\u003e\n\u003cp\u003eIn prehospital blood programs, the Rad-67 provides a fast, needle-free SpHb spot check that supports, but does not replace, the protocol's physiologic transfusion criteria and laboratory hemoglobin. SpHb should not on its own start, withhold, delay, or stop transfusion.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-8\"\u003e8\u003c\/a\u003e\u003c\/sup\u003e Results can display in as few as 30 seconds when the DCI-mini is connected.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-4\"\u003e4\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\n\u003cp\u003eThe 2025 Prehospital Blood Transfusion Coalition civilian EMS guideline uses suspected hemorrhagic shock and vital-sign criteria, not an SpHb cutoff. Those criteria include systolic blood pressure below 90 mm Hg (below 100 mm Hg if the patient is 65 or older), or a weak or absent radial pulse; a heart rate of 100 or more that does not respond to initial interventions; and a shock index (heart rate divided by systolic pressure) greater than 1.0. They are elements of a clinical algorithm under medical direction, not independent reasons to transfuse every patient with an abnormal vital sign.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-8\"\u003e8\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\n\u003cp\u003eMasimo's operator's manual is direct: do not use SpHb spot-check measurements as the sole basis for clinical decisions on blood transfusions. The labeled SpHb accuracy range is 8 to 17 g\/dL and does not include values below 8 g\/dL, which may be important when deciding whether to transfuse.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e SpHb is not intended to replace laboratory blood testing. Blood samples should be analyzed by laboratory instruments before clinical decision making.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-4\"\u003e4\u003c\/a\u003e\u003c\/sup\u003e A normal initial hemoglobin also does not exclude major bleeding; published trauma guidance cautions against transfusing on hemoglobin alone and recommends repeat measurements.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-9\"\u003e9\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\n\u003cp\u003eSpHb on the Rad-67 is indicated for adult patients only (18 years or older). It is not intended for pediatric patients, pregnant patients, or patients with renal disease. The device is not intended to measure SpHb on pregnant women.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\n\n\u003ch3\u003eWhat the studies support, and what they do not\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFinding\u003c\/th\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003cth\u003eHow we use it\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIn a selected trauma group with laboratory Hb below 8 g\/dL (70 patients, 184 paired readings), reported bias was +0.12 g\/dL and limits of agreement were -0.56 to +0.79 g\/dL.\u003c\/td\u003e\n\u003ctd\u003eGamal et al., Shock 2017\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-10\"\u003e10\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eSupportive in a narrow, in-hospital, low-Hb sample. Not a prehospital whole-blood trial, and figures are often repeated from manufacturer summaries.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuring critical-care air-transport training, SpHb was captured on 97.7% of ground readings and 97.2% of in-flight readings. Participants were healthy.\u003c\/td\u003e\n\u003ctd\u003eDavis et al., Military Medicine 2024\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-11\"\u003e11\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eShows it is often possible to obtain a value during transport. This is feasibility, not accuracy in hemorrhaging patients.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIn 23 combat casualties, reported bias was +0.3 +\/- 1.6 g\/dL, the signal was present 76% of the time, and trend direction agreed 86% of the time.\u003c\/td\u003e\n\u003ctd\u003ePubMed 27501120\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-12\"\u003e12\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eSmall sample at trauma hospitals, not in a moving ambulance. Average bias was small; individual error and signal gaps were not.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSome operating-room studies of continuous SpHb reported less red-cell use or earlier transfusion.\u003c\/td\u003e\n\u003ctd\u003ePubMed-indexed in-hospital series\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-13\"\u003e13\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eIn-hospital continuous monitoring, not a prehospital spot-check protocol.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAn emergency-department study of the Rad-67 and DCI-mini in 650 patients found a bias of 0.146 g\/dL and limits of agreement of -2.58 to 2.87 g\/dL versus the hospital analyzer (Pearson 0.812). The authors asked for more research on transfusion and outcomes.\u003c\/td\u003e\n\u003ctd\u003eAl Aseri et al., Am J Emerg Med 2022\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-14\"\u003e14\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eED spot-check agreement, not a prehospital transfusion trial.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA Level 1 trauma repeat study (218 paired measurements) found bias +0.5 g\/dL and limits of agreement of -3.6 to +4.1 g\/dL, and concluded SpHb was not suitable as an initial diagnostic tool for trauma hemoglobin assessment.\u003c\/td\u003e\n\u003ctd\u003eJost et al., J Surg Res 2021\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-15\"\u003e15\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eCite this limit. Individual errors can be several grams per deciliter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIn 711 trauma patients, adding SpHb values and trends did not significantly improve prediction of urgent transfusion over models that used conventional pulse-oximetry features.\u003c\/td\u003e\n\u003ctd\u003eGalvagno et al., 2015\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-16\"\u003e16\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eSpHb is not established as an independent field transfusion trigger.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA study of percutaneous hemoglobin reported that transfusion decisions based on SpHb would have been wrong in 27.1% of patients.\u003c\/td\u003e\n\u003ctd\u003eAnaesthesiol Intensive Ther\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-17\"\u003e17\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eThreshold-based use misclassifies patients. Do not import a cutoff into EMS.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIn patients at risk of hemorrhage, about 15% of measurements failed, and agreement with laboratory hemoglobin change was about 60%.\u003c\/td\u003e\n\u003ctd\u003eDTIC ADA626766\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-18\"\u003e18\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eA downward or stable trend is not automatically reliable.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow peripheral perfusion can degrade SpHb accuracy.\u003c\/td\u003e\n\u003ctd\u003eKondo, ESA 2013\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-19\"\u003e19\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eThis matters in the shock patients a blood program is meant to treat.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAn ARMS of about 1 g\/dL means roughly two-thirds of readings fall within 1 g\/dL of the reference in a controlled study, not that every reading does.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-4\"\u003e4\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\n\n\u003ch2\u003eCable compatibility: M20, RC, and RD\u003c\/h2\u003e\n\u003cp\u003eThe Rad-67 uses a rainbow M20 patient cable. One is in the 9794 kit. Some 3798 listings still say the sensor \"requires a rainbow RC series patient cable.\" That wording comes from older catalogs written for classic rainbow SET monitors. Do not buy an RC-1 or RC-4 for the Rad-67 just because a sensor page says \"RC.\"\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-20\"\u003e20\u003c\/a\u003e\u003c\/sup\u003e Verify the full combination of monitor, cable, and sensor before use; an incorrect set can degrade performance or injure the patient.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e See also our \u003ca href=\"\/pages\/masimo-equivalents\"\u003eMasimo part-number cross-reference\u003c\/a\u003e.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCable family\u003c\/th\u003e\n\u003cth\u003eExample part numbers\u003c\/th\u003e\n\u003cth\u003eFits which monitor\u003c\/th\u003e\n\u003cth\u003eFits which sensors\u003c\/th\u003e\n\u003cth\u003eUse with Rad-67 and 3798?\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003erainbow M20\u003c\/td\u003e\n\u003ctd\u003e4236 (M20-01, 1 ft), 4237 (M20-04, 4 ft)\u003c\/td\u003e\n\u003ctd\u003eRad-67 M20 port\u003c\/td\u003e\n\u003ctd\u003erainbow and M-LNCS sensors, including the DCI-mini\u003c\/td\u003e\n\u003ctd\u003eYes. This is the documented Rad-67 cable family.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-20\"\u003e20\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003erainbow RC\u003c\/td\u003e\n\u003ctd\u003e2405 (RC-1), 2406 (RC-4), 2404 (RC-12), and EMS RC cables 4480 and 4481\u003c\/td\u003e\n\u003ctd\u003eClassic 20-pin rainbow monitors such as the Rad-57 and Radical-7\u003c\/td\u003e\n\u003ctd\u003erainbow sensors, including the DCI-mini, on those monitors\u003c\/td\u003e\n\u003ctd\u003eNo, not on the Rad-67. Use RC when the 3798 is on a Rad-57 or similar classic rainbow SET device.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRD rainbow SET M20 or MD20\u003c\/td\u003e\n\u003ctd\u003eRD M20 cables (for example 4255, 4256, 4257) and MD20 cables (for example 4072, \u003ca href=\"\/products\/masimo-4073\"\u003e4073\u003c\/a\u003e, 4792)\u003c\/td\u003e\n\u003ctd\u003eRD or MD20 instrument connectors\u003c\/td\u003e\n\u003ctd\u003eRD rainbow SET and LNCS-II sensors, not the DCI-mini\u003c\/td\u003e\n\u003ctd\u003eNo. \"M20\" in an RD cable name is not the same as rainbow M20. Do not substitute.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-20\"\u003e20\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eRad-67 compared with Rad-57, Rad-97, Pronto, and HemoCue\u003c\/h2\u003e\n\u003cp\u003eThese are different tools. The table is factual, not a ranking. Choose the device that matches the job and the labeled parameters.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eRad-67 (9794)\u003c\/th\u003e\n\u003cth\u003eRad-57\u003c\/th\u003e\n\u003cth\u003eRad-97\u003c\/th\u003e\n\u003cth\u003ePronto\u003c\/th\u003e\n\u003cth\u003eHemoCue Hb 801\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRole\u003c\/td\u003e\n\u003ctd\u003eHandheld spot-check Pulse CO-Oximeter for SpO2 and needle-free SpHb\u003c\/td\u003e\n\u003ctd\u003eHandheld continuous Pulse CO-Oximetry; the usual Masimo tool for EMS carbon monoxide work when SpCO is enabled\u003c\/td\u003e\n\u003ctd\u003eCompact continuous monitor, with family models that can add capnography or non-invasive blood pressure\u003c\/td\u003e\n\u003ctd\u003eEarlier Masimo handheld SpHb spot-check platform\u003c\/td\u003e\n\u003ctd\u003eHandheld hemoglobin meter that uses a blood sample\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpO2 and pulse rate\u003c\/td\u003e\n\u003ctd\u003eYes, spot-check\u003c\/td\u003e\n\u003ctd\u003eYes, continuous\u003c\/td\u003e\n\u003ctd\u003eYes, continuous\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpHb\u003c\/td\u003e\n\u003ctd\u003eYes, adult spot-check; Next Generation SpHb needs the DCI-mini, sold separately\u003c\/td\u003e\n\u003ctd\u003eAvailable when that parameter is enabled\u003c\/td\u003e\n\u003ctd\u003eAvailable when enabled\u003c\/td\u003e\n\u003ctd\u003eSpot-check SpHb on that platform\u003c\/td\u003e\n\u003ctd\u003eInvasive: about 10 uL of capillary or venous blood; labeled range 1.0 to 25.6 g\/dL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpCO\u003c\/td\u003e\n\u003ctd\u003eNot a US feature on the 9794\u003c\/td\u003e\n\u003ctd\u003eAvailable on SpCO-configured kits\u003c\/td\u003e\n\u003ctd\u003eUpgradeable on supported configurations\u003c\/td\u003e\n\u003ctd\u003eNot the current EMS CO handheld of record\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarms and workflow\u003c\/td\u003e\n\u003ctd\u003eNo physiological alarms; touchscreen; stored, patient-tagged spot checks\u003c\/td\u003e\n\u003ctd\u003eContinuous readings and trend memory\u003c\/td\u003e\n\u003ctd\u003eContinuous trends, patient profiles, optional extra modules\u003c\/td\u003e\n\u003ctd\u003eSpot-check handheld\u003c\/td\u003e\n\u003ctd\u003eA blood-sample result, not a pulse-oximeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIf the assignment is firefighter or EMS carbon monoxide screening, see the \u003ca href=\"\/collections\/masimo-rad-57\"\u003eRad-57 collection\u003c\/a\u003e. If you need rainbow sensors and cables more broadly, see \u003ca href=\"\/collections\/masimo-rainbow-sensors\"\u003erainbow sensors\u003c\/a\u003e and \u003ca href=\"\/collections\/masimo-rainbow-cables\"\u003erainbow cables\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eProduct Highlights\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSpot-check SpO2, pulse rate, perfusion index, and SpHb on one handheld, with a color touchscreen, patient identifiers, and storage for up to 2,000 spot-check sessions.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-4\"\u003e4\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eMasimo SET Measure-through Motion and Low Perfusion pulse oximetry for SpO2 and pulse rate.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-4\"\u003e4\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eNext Generation SpHb when used with the DCI-mini; results display in as few as 30 seconds, with signal-quality indicators.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-4\"\u003e4\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eRechargeable lithium-ion battery, up to 6 hours at the lowest indicator brightness with wireless off, and about 6 hours to charge.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eWireless printing of results at the point of care on a compatible printer.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-4\"\u003e4\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMasimo Part Number\u003c\/th\u003e\n\u003ctd\u003e9794\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003ctd\u003eMAS-9794\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Family\u003c\/th\u003e\n\u003ctd\u003eRad-67 Pulse CO-Oximeter\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice Type\u003c\/th\u003e\n\u003ctd\u003eHandheld spot-check Pulse CO-Oximeter kit\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUS parameters in this kit\u003c\/th\u003e\n\u003ctd\u003eSpO2, pulse rate, perfusion index, SpHb\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpO2 accuracy (DCI-mini, 70-100%)\u003c\/th\u003e\n\u003ctd\u003e2% ARMS no motion and low perfusion; 3% ARMS motion; adults, pediatrics, and infants\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-4\"\u003e4\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse rate accuracy (25-240 bpm)\u003c\/th\u003e\n\u003ctd\u003e3 bpm ARMS no motion and low perfusion; 5 bpm ARMS motion\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-4\"\u003e4\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpHb accuracy range\u003c\/th\u003e\n\u003ctd\u003e8-17 g\/dL, adults only. Operator's manual: -1.82 to 2.07 g\/dL (660 samples).\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpHb resolution\u003c\/th\u003e\n\u003ctd\u003e0.1 g\/dL\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery\u003c\/th\u003e\n\u003ctd\u003eLithium-ion, up to 6 hours; 6 hours charge time\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eBacklit TFT LCD, 720 x 1280\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e7.6 x 3.2 x 0.9 in (19.4 x 8.2 x 2.4 cm)\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.81 lb (0.37 kg) for the device\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIngress\u003c\/th\u003e\n\u003ctd\u003eIP24\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e32 to 95 F (0 to 35 C)\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGTIN\u003c\/th\u003e\n\u003ctd\u003e00843997012812\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eBuying, lead time, and warranty\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAuthorized Masimo distributor. Units ship new, in original Masimo packaging, not refurbished.\u003c\/li\u003e\n\u003cli\u003eCheckout asks for a clinical attestation before this order ships.\u003c\/li\u003e\n\u003cli\u003eLead time: Masimo quote 00575076 stated delivery in 2 to 4 weeks after receipt of order. That quote expired on 2026-09-28, so confirm the current lead time when you order.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eWarranty, as printed in the US operator's manual: Masimo warrants the Rad-67 hardware to the original end-user against defects in material and workmanship for 12 months, and the battery for 6 months, from the date the end-user obtained the product, subject to the exclusions in LAB-10262D. The remedy is repair or replacement at Masimo's option.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eWe accept orders when the item is not on the shelf. Add MAS-9794 to your cart, or contact CustomerService@pacificbiomedical.com or 844.436.3526. We support net terms for agencies and hospitals and ship to all 50 states.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eDirections for use and official documents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRad-67 product information: \u003ca href=\"https:\/\/www.masimo.com\/siteassets\/us\/documents\/pdf\/plm-11186b-product-information-rad-67-us.pdf\"\u003ePLM-11186B\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eRad-67 Operator's Manual: \u003ca href=\"https:\/\/techdocs.masimo.com\/globalassets\/techdocs\/pdf\/lab-10262d_master.pdf\"\u003eLAB-10262D\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eNext Generation SpHb product information: \u003ca href=\"https:\/\/www.masimo.com\/siteassets\/us\/documents\/pdf\/plm-11187a-product-information-spot-check-sphb-us.pdf\"\u003ePLM-11187A\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eDCI-mini directions for use: \u003ca href=\"https:\/\/techdocs.masimo.com\/globalassets\/techdocs\/pdf\/lab-10263a-eifu.pdf\"\u003eLAB-10263A\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eDCI-mini product information: \u003ca href=\"https:\/\/www.masimo.com\/siteassets\/us\/documents\/pdf\/plm-11188b-product-information-rainbow-dci-mini-sensor-us.pdf\"\u003ePLM-11188B\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eSET and rainbow sensor and cable compatibility (US): \u003ca href=\"https:\/\/professional.masimo.com\/siteassets\/us\/documents\/pdf\/plm-10747d-sales-tool-sensor-and-cable-compatibility-us.pdf\"\u003ePLM-10747D\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat's included in the Masimo Rad-67 9794 kit? Does it include a DCI-mini SpHb sensor?\u003c\/h3\u003e\n\u003cp\u003eThe 9794 kit includes the Rad-67 with SpO2, pulse rate, perfusion index, and SpHb, and one rainbow M20 patient cable.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e It does not include a DCI-mini sensor. Order \u003ca href=\"\/products\/masimo-3798\"\u003e3798\u003c\/a\u003e (400 spot checks) separately if you want Next Generation SpHb. The AC power supply is part of the Rad-67 system in the manual; confirm it on the packing list.\u003c\/p\u003e\n\u003ch3\u003eHow much does the Rad-67 cost, and what's the total cost with sensor and spot checks?\u003c\/h3\u003e\n\u003cp\u003eThis 9794 kit is $1,215. The 3798 sensor is quote-only until we have a current dealer cost, so the combined total depends on that quote. Part 9826 is a different kit that, in authorized-distributor listings, already includes a 400-check DCI-mini; we are not listing 9826 on this page.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between 9794, 9825, and 9826?\u003c\/h3\u003e\n\u003cp\u003e9794 is the Rad-67 with an M20 cable and no sensor. Authorized-distributor listings describe 9825 as a Rad-67 kit with a 200-check DCI-mini (SC-200) and 9826 as a Rad-67 adult starter kit with a 400-check DCI-mini (SC-400).\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-5\"\u003e5\u003c\/a\u003e\u003c\/sup\u003e Confirm the exact part number, the cable, and whether a sensor is included before you compare prices.\u003c\/p\u003e\n\u003ch3\u003eDoes the Rad-67 measure SpCO or SpMet? Can it be upgraded?\u003c\/h3\u003e\n\u003cp\u003eNot on this US 9794 kit. US indications are SpO2, pulse rate, and adult SpHb. SpCO and SpMet appear as optional upgrades only in an international brochure that excludes the US and Canada.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-21\"\u003e21\u003c\/a\u003e\u003c\/sup\u003e Confirm any upgrade with Masimo before you promise one. For field CO screening, use a Rad-57 kit that includes SpCO.\u003c\/p\u003e\n\u003ch3\u003eRad-67 vs Rad-57 vs Rad-97: which is better for EMS?\u003c\/h3\u003e\n\u003cp\u003eThey do different jobs. The Rad-67 is a spot-check device for needle-free SpHb and SpO2, with no physiological alarms. The Rad-57 is the usual Masimo handheld for continuous monitoring and, when configured, carbon monoxide (SpCO) work. The Rad-97 is a larger continuous monitor with optional capnography or blood-pressure models. See the comparison table above. A HemoCue Hb 801 is a different tool: it measures hemoglobin from a blood sample, not from a finger sensor.\u003c\/p\u003e\n\u003ch3\u003eCan SpHb be used to decide on prehospital blood transfusion or whole blood?\u003c\/h3\u003e\n\u003cp\u003eNot by itself. Use it as a fast, needle-free adjunct to the clinical picture, vital signs, and the service's approved protocol. The 2025 Prehospital Blood Transfusion Coalition guideline uses suspected hemorrhagic shock and vital-sign criteria, not an SpHb cutoff.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-8\"\u003e8\u003c\/a\u003e\u003c\/sup\u003e Do not use SpHb as the sole basis for transfusion decisions, and do not wait on an SpHb value when hemorrhage resuscitation is already indicated.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e A normal or stable SpHb must not be used to withhold otherwise indicated blood.\u003c\/p\u003e\n\u003ch3\u003eHow accurate is SpHb in trauma and EMS?\u003c\/h3\u003e\n\u003cp\u003eIt depends on the study. A selected low-Hb trauma series reported tight limits of agreement, and an ED study of the Rad-67 found acceptable average agreement with laboratory hemoglobin.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-10\"\u003e10\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-14\"\u003e14\u003c\/a\u003e\u003c\/sup\u003e A Level 1 trauma repeat study found limits of agreement from about -3.6 to +4.1 g\/dL and concluded SpHb was not suitable for initial trauma hemoglobin assessment.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-15\"\u003e15\u003c\/a\u003e\u003c\/sup\u003e Adding SpHb did not improve transfusion prediction in 711 trauma patients.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-16\"\u003e16\u003c\/a\u003e\u003c\/sup\u003e Transport data show that a value can often be captured in flight, but that study used healthy trainees and did not test accuracy in bleeding patients.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-11\"\u003e11\u003c\/a\u003e\u003c\/sup\u003e Treat SpHb as adjunctive.\u003c\/p\u003e\n\u003ch3\u003eWhat are SpHb's limitations vs lab hemoglobin, and what is the validated range?\u003c\/h3\u003e\n\u003cp\u003eSpHb does not replace laboratory hemoglobin.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-4\"\u003e4\u003c\/a\u003e\u003c\/sup\u003e The labeled range is 8 to 17 g\/dL and does not include values below 8 g\/dL.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e Low perfusion, motion, and several clinical conditions can degrade accuracy.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-19\"\u003e19\u003c\/a\u003e\u003c\/sup\u003e About two-thirds of readings in controlled studies fall within the published ARMS or limits of agreement, not every reading.\u003c\/p\u003e\n\u003ch3\u003eHow many spot checks does the 3798 have, and what happens when they run out?\u003c\/h3\u003e\n\u003cp\u003eThe 3798 is an SC-400 sensor, rated for 400 spot checks, not 400 unique patients. X-Cal stops the sensor once that rating is used up. Do not assume it will keep working as an SpO2-only sensor afterward.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-6\"\u003e6\u003c\/a\u003e\u003c\/sup\u003e Replace it when the device reports that the sensor is expired or must be replaced.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between 3798 and 3799 (400 vs 1,000)?\u003c\/h3\u003e\n\u003cp\u003eBoth are rainbow DCI-mini reusable sensors. 3798 is the 400-spot-check (SC-400) version, which we list as quote-only. 3799 is the 1,000-spot-check version, a different part number that is not this kit and not our 3798 page.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-7\"\u003e7\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\n\u003ch3\u003eWhich cable does the Rad-67 use: M20 or RC? Does the 3798 really need an RC cable?\u003c\/h3\u003e\n\u003cp\u003eThe Rad-67 uses a rainbow M20 cable. One is in the 9794 kit. Replacement examples are 4236 (1 ft) and 4237 (4 ft).\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e The \"requires RC\" line on some 3798 listings comes from older catalogs for classic rainbow SET monitors such as the Rad-57. Do not buy an RC cable for the Rad-67. Use an RC cable when the 3798 is connected to a Rad-57 or similar 20-pin rainbow monitor. Do not use an RD M20 or MD20 cable with the DCI-mini.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-20\"\u003e20\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\n\u003ch3\u003eWhich monitors are compatible with the DCI-mini 3798?\u003c\/h3\u003e\n\u003cp\u003eThe sensor directions for use say rainbow DCI-mini reusable sensors are for devices containing Masimo rainbow SET technology, version 7.4 or higher, or a licensed device, with the SpHb parameter enabled for hemoglobin readings.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-6\"\u003e6\u003c\/a\u003e\u003c\/sup\u003e On a Rad-67, use the rainbow M20 cable. On a Rad-57 or other classic rainbow SET monitor, use a rainbow RC series cable. A matching plug is not enough; confirm the monitor, cable, sensor, and enabled parameters.\u003c\/p\u003e\n\u003ch3\u003eCan the Rad-67 be used on pediatric or pregnant patients, or patients with renal disease?\u003c\/h3\u003e\n\u003cp\u003eSpO2 and pulse rate may be used on adult and pediatric patients as labeled. SpHb is indicated for adults only and is not intended for pediatric patients, pregnant patients, or patients with renal disease. The manual lists pregnancy as a contraindication for SpHb measurement.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\n\u003ch3\u003eIs the Rad-67 a continuous monitor? Does it have alarms?\u003c\/h3\u003e\n\u003cp\u003eNo. It is a spot-check device. The manual states that it provides no physiological alarms and is not intended as an apnea monitor.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\n\u003ch3\u003eHow long does the battery last?\u003c\/h3\u003e\n\u003cp\u003eThe built-in lithium-ion battery is rated for up to 6 hours at the lowest indicator brightness with wireless functions off, and about 6 hours to charge, per LAB-10262D.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e Runtime is shorter if the display is bright or wireless is on. The limited warranty on the battery is 6 months from the date the end-user obtained the product.\u003c\/p\u003e\n\n\u003ch2 id=\"references\"\u003eReferences\u003c\/h2\u003e\n\u003col\u003e\n\u003cli id=\"ref-1\"\u003eMasimo. Quotation 00575076, Pacific Biomedical, 9794 Kit, Rad-67, including one rainbow M20 patient cable. Created 2026-07-01, expired 2026-09-28. Delivery stated as 2-4 weeks after receipt of order. Opened 2026-11-21.\u003c\/li\u003e\n\u003cli id=\"ref-2\"\u003eMasimo. Product Catalog 2024 Q3, PLM-10062P. Handheld Instruments, part 9794, Rad-67; Sensors, part 3798, rainbow DCI-mini SC-400; Cables, parts 4236 and 4237, rainbow M20. August 2024.\u003c\/li\u003e\n\u003cli id=\"ref-3\"\u003eMasimo. Rad-67 Pulse CO-Oximeter Operator's Manual, Spot-Check, for sale in the USA. LAB-10262D. Indications, contraindications, transfusion warning, specifications, limited warranty (12 months hardware, 6 months battery). \u003ca href=\"https:\/\/techdocs.masimo.com\/globalassets\/techdocs\/pdf\/lab-10262d_master.pdf\"\u003ehttps:\/\/techdocs.masimo.com\/globalassets\/techdocs\/pdf\/lab-10262d_master.pdf\u003c\/a\u003e. Opened 2026-11-21.\u003c\/li\u003e\n\u003cli id=\"ref-4\"\u003eMasimo. Noninvasive Next Generation SpHb Technology \/ Rad-67 product information. PLM-11187A-0419 and PLM-11186B-0419, 2019. \u003ca href=\"https:\/\/www.masimo.com\/siteassets\/us\/documents\/pdf\/plm-11187a-product-information-spot-check-sphb-us.pdf\"\u003ePLM-11187A\u003c\/a\u003e. \u003ca href=\"https:\/\/www.masimo.com\/siteassets\/us\/documents\/pdf\/plm-11186b-product-information-rad-67-us.pdf\"\u003ePLM-11186B\u003c\/a\u003e. Opened 2026-11-21.\u003c\/li\u003e\n\u003cli id=\"ref-5\"\u003eAuthorized-distributor listings for Masimo 9825 (Rad-67 with DCI-mini SC-200, 200 spot checks) and 9826 (Rad-67 adult starter kit with DCI-mini SC-400, 400 spot checks), including Discount Catheters, Concord Health Supply, MFI Medical, and Medequip Depot, as summarized in the 2026-11-21 Perplexity run (p01, p08). These kit numbers are not on our 2024 Q3 catalog extract. Opened 2026-11-21.\u003c\/li\u003e\n\u003cli id=\"ref-6\"\u003eMasimo. Directions for Use, rainbow DCI-mini Series Reusable SpHb and SpO2 Sensors. LAB-10263A-eIFU-0419. Includes rainbow SET version 7.4 or higher, X-Cal, and a one-year limited warranty to the initial buyer. \u003ca href=\"https:\/\/techdocs.masimo.com\/globalassets\/techdocs\/pdf\/lab-10263a-eifu.pdf\"\u003ehttps:\/\/techdocs.masimo.com\/globalassets\/techdocs\/pdf\/lab-10263a-eifu.pdf\u003c\/a\u003e. Opened 2026-11-21.\u003c\/li\u003e\n\u003cli id=\"ref-7\"\u003eMasimo technical documents and DCI-mini product information list part IDs 3797, 3798, and 3799 in the rainbow DCI-mini series, with 3798 as the 400-spot-check SC-400 and 3799 as the 1,000-spot-check version (PLM-11188B; techdocs rainbow DCI-mini series index). \u003ca href=\"https:\/\/techdocs.masimo.com\/products\/sensor\/rainbow-dci-mini-series-reusable-sphb-spo2-sensor\/\"\u003etechdocs index\u003c\/a\u003e. Opened 2026-11-21.\u003c\/li\u003e\n\u003cli id=\"ref-8\"\u003ePrehospital Blood Transfusion Coalition. Clinical Practice Guideline for Civilian Emergency Medical Services, 2025. Physiologic criteria for transfusion; no SpHb cutoff. \u003ca href=\"https:\/\/prehospitaltransfusion.org\/wp-content\/uploads\/2025\/06\/PHBTC-CPG-final-BOD-app-6-3-25.pdf\"\u003eprehospitaltransfusion.org PDF\u003c\/a\u003e. Opened 2026-11-21.\u003c\/li\u003e\n\u003cli id=\"ref-9\"\u003eRossaint R, Afshari A, Bouillon B, et al. The European guideline on management of major bleeding and coagulopathy following trauma: sixth edition. Crit Care. 2023. doi:10.1186\/s13054-023-04327-7. Opened 2026-11-21.\u003c\/li\u003e\n\u003cli id=\"ref-10\"\u003eGamal M, et al. Evaluation of noninvasive hemoglobin monitoring in trauma patients with low hemoglobin. Shock. 2017. Figures as commonly summarized on Masimo SpHb Outcomes and related pages. Opened 2026-11-21.\u003c\/li\u003e\n\u003cli id=\"ref-11\"\u003eDavis WT, et al. Noninvasive hemoglobin monitoring during critical care air transport training. Mil Med. 2024;189(S3):448. Opened 2026-11-21.\u003c\/li\u003e\n\u003cli id=\"ref-12\"\u003eAccuracy of noninvasive hemoglobin monitoring in combat casualties. PubMed 27501120. Opened 2026-11-21.\u003c\/li\u003e\n\u003cli id=\"ref-13\"\u003eIn-hospital continuous SpHb transfusion-management studies, including PMC4621711 and PMC13267314, as listed on Masimo SpHb Outcomes. Opened 2026-11-21.\u003c\/li\u003e\n\u003cli id=\"ref-14\"\u003eAl Aseri ZAA, Aldawood BA, Altamimi AA, et al. Accuracy of noninvasive hemoglobin level measurement in the emergency department. Am J Emerg Med. 2022. doi:10.1016\/j.ajem.2022.11.012. Opened 2026-11-21.\u003c\/li\u003e\n\u003cli id=\"ref-15\"\u003eJost G, et al. Evaluation of noninvasive hemoglobin measurements in trauma patients: a repeat study. J Surg Res. 2021. PubMed 34023577. Opened 2026-11-21.\u003c\/li\u003e\n\u003cli id=\"ref-16\"\u003eGalvagno SM Jr, Hu P, Yang S, et al. Accuracy of continuous noninvasive hemoglobin monitoring for the prediction of blood transfusion in trauma. 2015. PubMed 25753142. Opened 2026-11-21.\u003c\/li\u003e\n\u003cli id=\"ref-17\"\u003eBlood transfusion decisions cannot be based on percutaneous haemoglobin measurements. Anaesthesiol Intensive Ther. PMC10158438. Opened 2026-11-21.\u003c\/li\u003e\n\u003cli id=\"ref-18\"\u003eAccuracy of Noninvasive Hemoglobin Monitoring in Patients at Risk for Hemorrhage. Defense Technical Information Center, ADA626766. Opened 2026-11-21.\u003c\/li\u003e\n\u003cli id=\"ref-19\"\u003eKondo. Influence of peripheral perfusion index on accuracy of noninvasive hemoglobin monitoring. ESA 2013. Masimo clinical-evidence PDF. Opened 2026-11-21.\u003c\/li\u003e\n\u003cli id=\"ref-20\"\u003eMasimo. SET and rainbow Sensor and Cable Compatibility, US. PLM-10747D. \u003ca href=\"https:\/\/professional.masimo.com\/siteassets\/us\/documents\/pdf\/plm-10747d-sales-tool-sensor-and-cable-compatibility-us.pdf\"\u003ehttps:\/\/professional.masimo.com\/siteassets\/us\/documents\/pdf\/plm-10747d-sales-tool-sensor-and-cable-compatibility-us.pdf\u003c\/a\u003e. See also the 2026-11-21 cable-compatibility review citing rainbow M20 parts 4236 and 4237. Opened 2026-11-21.\u003c\/li\u003e\n\u003cli id=\"ref-21\"\u003eMasimo. Rad-67 product information, UK\/international, PLM-10356C, 2018, which lists optional SpCO and SpMet and excludes the US and Canada. \u003ca href=\"https:\/\/www.masimo.co.uk\/siteassets\/uk\/documents\/pdf\/plm-10356c_product_information_rad-67_british.pdf\"\u003ePLM-10356C\u003c\/a\u003e. Opened 2026-11-21.\u003c\/li\u003e\n\u003c\/ol\u003e\n","brand":"Masimo Corporation","offers":[{"title":"Default Title","offer_id":53681674027319,"sku":"MAS-9794","price":1215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/7415\/6599\/files\/MAS-9794__masimo-official-rad67-in-hand.jpg?v=1795261888","url":"https:\/\/shop.pacificbiomedical.com\/products\/masimo-9794","provider":"Pacific Biomedical","version":"1.0","type":"link"}