{"product_id":"gt-284ma-15ly1","title":"Gentec Click-Style Oxygen Regulator, 0.5-15 LPM, Hose Barb and DISS Outlet, CGA 870, 284MA-15LY1","description":"\u003cdiv class=\"pbm-product pbm-faq-aligned\"\u003e \u003ch2 style=\"text-align: center;\"\u003eGentec Click-Style Oxygen Regulator, 0.5-15 LPM, Hose Barb and DISS Outlet, CGA 870, 284MA-15LY1\u003c\/h2\u003e \u003cdiv class=\"pbm-lead\"\u003eThe \u003cstrong\u003eGentec 284MA-15LY1 click-style oxygen regulator\u003c\/strong\u003e by Genstar Technologies mounts on a medical oxygen cylinder with a CGA 870 yoke and delivers 0.5 to 15 LPM through a hose barb outlet, plus one DISS outlet at a 50 psi delivery pressure.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e It has an aluminum body with a brass high-pressure chamber, a 3000 psi maximum inlet pressure, a 1-1\/2 in UL-listed contents gauge, an internal relief valve and a sintered bronze inlet filter.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e Pacific Biomedical carries it with its \u003ca href=\"\/collections\/oxygen-regulators\"\u003eoxygen regulators\u003c\/a\u003e. \u003c\/div\u003e \u003ch2\u003eProduct Highlights:\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eTwelve click settings:\u003c\/strong\u003e 0, 0.5, 1, 2, 3, 4, 5, 6, 7, 8, 10 and 15 LPM, read in an easy-to-read flow rate window.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eHose barb plus DISS power take off:\u003c\/strong\u003e A hose barb outlet and one DISS outlet at 50 psi delivery pressure; Gentec calls this DISS outlet a power take off on its click-style regulators.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCGA 870 yoke inlet:\u003c\/strong\u003e Fits medical oxygen cylinders with a CGA 870 yoke valve, such as size E cylinders.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt for cylinder pressure:\u003c\/strong\u003e 3000 psi maximum inlet pressure, internal relief valve and piston design regulator.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eInlet filter:\u003c\/strong\u003e Sintered bronze inlet filter for longer service life.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBody:\u003c\/strong\u003e Aluminum body with a brass high-pressure chamber.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eWhat's Included:\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e1 Gentec 284MA-15LY1 click-style oxygen regulator\u003c\/li\u003e \u003cli\u003eNot included: the oxygen cylinder, oxygen tubing, cannula or mask\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eSpecifications:\u003c\/h2\u003e \u003ctable class=\"pbm-table\"\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth style=\"width:38%;\"\u003eProduct\u003c\/th\u003e \u003ctd\u003eClick-style oxygen regulator with hose barb and one DISS outlet\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBrand\u003c\/th\u003e \u003ctd\u003eGentec (Genstar Technologies)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003ePart number\u003c\/th\u003e \u003ctd\u003e284MA-15LY1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003ePacific Biomedical SKU\u003c\/th\u003e \u003ctd\u003eGT-284MA-15LY1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eGas\u003c\/th\u003e \u003ctd\u003eOxygen\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eFlow settings (LPM)\u003c\/th\u003e \u003ctd\u003e0, 0.5, 1, 2, 3, 4, 5, 6, 7, 8, 10, 15\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eOutlets\u003c\/th\u003e \u003ctd\u003eHose barb; 1 DISS outlet\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eDelivery pressure\u003c\/th\u003e \u003ctd\u003e50 psi\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eInlet connection\u003c\/th\u003e \u003ctd\u003eCGA 870 yoke\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMaximum inlet pressure\u003c\/th\u003e \u003ctd\u003e3000 psi\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eContents gauge\u003c\/th\u003e \u003ctd\u003e1-1\/2 in diameter, UL-listed\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eBody\u003c\/th\u003e \u003ctd\u003eAluminum with brass high-pressure chamber\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eDesign\u003c\/th\u003e \u003ctd\u003ePiston design regulator; internal relief valve; sintered bronze inlet filter\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eStandards\u003c\/th\u003e \u003ctd\u003eComplies to CGA standards\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eMedical air version\u003c\/th\u003e \u003ctd\u003e287MA-15LY1, CGA 950 inlet\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e \u003ch2\u003eUse Cases:\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eOxygen delivery through tubing on the hose barb from a medical oxygen cylinder with a CGA 870 yoke valve\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e \u003cli\u003eSupplying oxygen at 50 psi to equipment with a DISS oxygen inlet, from the DISS outlet\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eCompatible products:\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e\n\u003ca href=\"\/products\/products-adapter-diss-f-o2-to-14-hose-barb-green-0124\"\u003ePrecision Medical 0124 DISS-F oxygen to 1\/4 in hose barb adapter\u003c\/a\u003e, which threads onto the DISS outlet\u003c\/li\u003e \u003cli\u003e\u003ca href=\"\/collections\/oxygen-regulators\"\u003eAll oxygen regulators\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eFrequently Asked Questions:\u003c\/h2\u003e \u003cdetails\u003e\u003csummary\u003eWhat is a click-style oxygen regulator?\u003c\/summary\u003e\u003cp\u003eIt is a cylinder regulator with a set of fixed flow settings. The Gentec 284MA-15LY1 is a piston design click-style regulator with 12 settings from 0 to 15 LPM shown in a flow rate window, and a 50 psi delivery pressure.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e \u003cdetails\u003e\u003csummary\u003eWhat flow rates does this oxygen regulator have?\u003c\/summary\u003e\u003cp\u003e0, 0.5, 1, 2, 3, 4, 5, 6, 7, 8, 10 and 15 LPM.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e For flows above 15 LPM, Gentec offers the 284MA-25LY1, which tops out at 25 LPM.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e \u003cdetails\u003e\u003csummary\u003eWhat is the DISS outlet on an oxygen regulator for?\u003c\/summary\u003e\u003cp\u003eThe 284MA-15LY1 has one DISS outlet that delivers oxygen at 50 psi, alongside the hose barb.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e Gentec calls this a DISS power take off outlet on its click-style regulators, and it supplies equipment with a DISS oxygen connection from the same cylinder.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e Models with a -15LY2 suffix have two DISS outlets, and models without the 1 or 2 suffix have none.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e On the 284MA-15LY1 the DISS outlet is the threaded male fitting below the gauge, and a female DISS oxygen fitting such as the \u003ca href=\"\/products\/products-adapter-diss-f-o2-to-14-hose-barb-green-0124\"\u003ePrecision Medical 0124 adapter\u003c\/a\u003e threads onto it.\u003c\/p\u003e\u003c\/details\u003e \u003cdetails\u003e\u003csummary\u003eWhat oxygen tank does a CGA 870 regulator fit?\u003c\/summary\u003e\u003cp\u003eMedical oxygen cylinders with a CGA 870 yoke valve, such as size E medical oxygen cylinders.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e The 284MA-15LY1 has a CGA 870 yoke inlet and is for oxygen only.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e For CGA 540 cylinder valves, Gentec makes the 284MA-15L1, and the medical air version of this regulator is the 287MA-15LY1 with a CGA 950 inlet.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e \u003cdetails\u003e\u003csummary\u003eHow do you put an oxygen regulator on an E tank?\u003c\/summary\u003e\u003cp\u003eCheck that one yoke seal washer is in place and in good condition on the regulator inlet, slide the yoke over the cylinder post valve, seat the index pins in the valve holes without forcing them, and hand tighten the T-handle screw into the dimple on the valve.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e Turn the flow setting to 0, stand with the cylinder between you and the regulator, open the cylinder valve slowly, and confirm pressure on the gauge.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e \u003cdetails\u003e\u003csummary\u003eHow long does an E tank last?\u003c\/summary\u003e\u003cp\u003eDuration in minutes equals cylinder pressure in psig times the cylinder factor, divided by flow in LPM; the E cylinder factor is 0.28, and planning to change the cylinder at about 500 psig gives a safer estimate.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-4\"\u003e4\u003c\/a\u003e\u003c\/sup\u003e At a gauge reading of 2,000 psig with a 500 psig reserve, an E cylinder provides about:\u003c\/p\u003e \u003ctable class=\"pbm-table\"\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth\u003eFlow setting\u003c\/th\u003e \u003cth\u003eApproximate time\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e1 LPM\u003c\/td\u003e \u003ctd\u003e420 min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e2 LPM\u003c\/td\u003e \u003ctd\u003e210 min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e3 LPM\u003c\/td\u003e \u003ctd\u003e140 min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e4 LPM\u003c\/td\u003e \u003ctd\u003e105 min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e5 LPM\u003c\/td\u003e \u003ctd\u003e84 min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e6 LPM\u003c\/td\u003e \u003ctd\u003e70 min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e8 LPM\u003c\/td\u003e \u003ctd\u003e53 min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e10 LPM\u003c\/td\u003e \u003ctd\u003e42 min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e15 LPM\u003c\/td\u003e \u003ctd\u003e28 min\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003eThese are calculated from the formula above; use your own gauge reading and protocol.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-4\"\u003e4\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e \u003cdetails\u003e\u003csummary\u003eHow do you check how much oxygen is left in the tank?\u003c\/summary\u003e\u003cp\u003eRead the contents gauge. The 284MA-15LY1 has a 1-1\/2 in UL-listed gauge reading to 3000 psi, the regulator's maximum inlet pressure.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e A cylinder approaching 500 psig is near the point where it should be replaced.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-4\"\u003e4\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e \u003cdetails\u003e\u003csummary\u003eWhy is my oxygen regulator leaking at the tank?\u003c\/summary\u003e\u003cp\u003eFor a leak between the regulator and the cylinder, close the cylinder valve and vent the regulator before adjusting anything, never tighten fittings under pressure, then inspect or replace the yoke washer and reattach.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e Use only one yoke seal washer, replace it every 6 months or after a leak, and check connections with an oxygen-compatible leak test solution.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e \u003cdetails\u003e\u003csummary\u003eWhat connects to the hose barb outlet?\u003c\/summary\u003e\u003cp\u003eOxygen tubing for a cannula, mask or other oxygen delivery device. The hose barb carries the selected click flow from 0.5 to 15 LPM.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e \u003cdetails\u003e\u003csummary\u003eIs this a genuine Gentec regulator?\u003c\/summary\u003e\u003cp\u003eYes. This is the new Gentec 284MA-15LY1 click-style oxygen regulator; Gentec is the medical product brand of Genstar Technologies Inc.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e Pacific Biomedical supplies it new.\u003c\/p\u003e\u003c\/details\u003e \u003cdetails\u003e\u003csummary\u003eHow fast does this ship?\u003c\/summary\u003e\u003cp\u003ePrepaid, in-stock orders placed before 12:00 PM Arizona time typically ship the same business day via UPS within the United States, and shipping cost is calculated at checkout. For lead times or expedited options, contact CustomerService@pacificbiomedical.com or 844.436.3526.\u003c\/p\u003e\u003c\/details\u003e \u003cdetails\u003e\u003csummary\u003eHow do I order by purchase order or get fleet pricing?\u003c\/summary\u003e\u003cp\u003eAdd it to your cart on this page, or contact CustomerService@pacificbiomedical.com or 844.436.3526 for a purchase order or pricing on multiple regulators.\u003c\/p\u003e\u003c\/details\u003e \u003cdiv class=\"pbm-refs\"\u003e\u003cdetails\u003e\u003csummary\u003eReferences\u003c\/summary\u003e\u003col\u003e \u003cli id=\"ref-1\"\u003eGenstar Technologies Inc. GENTEC Medical Products: Solutions for Life (catalog). Oxygen Therapy, Medical Gas Regulators, 284, 285 Series Oxygen Aluminum Medical Gas Regulators: features and ordering information, pages 22 and 24 (285MA-15L1 one DISS power take off outlet; oxygen use; aluminum body with brass high pressure chamber; 3000 psi maximum inlet pressure; 1-1\/2 in UL-listed gauge; complies to CGA standards; internal relief valve; hose barb outlet; piston design regulator; sintered bronze inlet filter; flow rate window; 284MA-15LY1 \/ 287MA-15LY1 flow settings 0, 0.5, 1, 2, 3, 4, 5, 6, 7, 8, 10, 15 LPM, 1 DISS outlet, 50 psi delivery pressure, CGA 870 \/ CGA 950 inlet). Accessed October 30, 2026. \u003ca href=\"https:\/\/www.tesuco.com.au\/media\/89016\/MED_OXY_V02.pdf\" rel=\"noopener\" target=\"_blank\"\u003etesuco.com.au\u003c\/a\u003e.\u003c\/li\u003e \u003cli id=\"ref-2\"\u003eAirgas. USP medical grade oxygen, size E high pressure steel medical cylinder, CGA 870 yoke fitting (OX USPE). Accessed October 30, 2026. \u003ca href=\"https:\/\/newemarket.airgas.com\/product\/Gases\/Oxygen\/p\/OX%20USPE\" rel=\"noopener\" target=\"_blank\"\u003eairgas.com\u003c\/a\u003e.\u003c\/li\u003e \u003cli id=\"ref-3\"\u003eO-Two Medical Technologies Inc. Pressure Regulators for Use with Medical Gases, 01R series, instructions for use, Part 15PL2171 Rev 23. Brampton, ON; November 2016 (pin index installation; one yoke seal washer; index pins not forced; flow selector at 0; stand behind the cylinder; open the cylinder valve slowly; never tighten fittings under pressure; replace the yoke seal washer every 6 months or after a leak; leak test solution; no oil or grease). Accessed October 30, 2026. \u003ca href=\"https:\/\/otwo.com\/wp-content\/uploads\/Pressure-Regulator-Manual-Rev23.pdf\" rel=\"noopener\" target=\"_blank\"\u003eotwo.com\u003c\/a\u003e.\u003c\/li\u003e \u003cli id=\"ref-4\"\u003eLandry J. Oxygen Cylinder: Uses, Safety, Sizes, and Duration. Respiratory Therapy Zone. Updated September 25, 2026 (duration = cylinder pressure x cylinder factor \/ flow; E cylinder factor 0.28 L\/psig; reserve-adjusted duration; replace the cylinder at about 500 psig). Accessed October 30, 2026. \u003ca href=\"https:\/\/www.respiratorytherapyzone.com\/?p=336555\" rel=\"noopener\" target=\"_blank\"\u003erespiratorytherapyzone.com\u003c\/a\u003e.\u003c\/li\u003e \u003c\/ol\u003e\u003c\/details\u003e\u003c\/div\u003e \u003cp\u003e\u003cem\u003eUse no oil or grease on oxygen equipment.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e Follow the cylinder and regulator instructions for setup and use.\u003c\/em\u003e\u003c\/p\u003e \u003c\/div\u003e","brand":"Genstar Technologies","offers":[{"title":"Default Title","offer_id":52800129499447,"sku":"GT-284MA-15LY1","price":55.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/7415\/6599\/files\/gentec-284ma-15ly1-click-style-oxygen-regulator-diss-outlet.jpg?v=1793405380","url":"https:\/\/shop.pacificbiomedical.com\/products\/gt-284ma-15ly1","provider":"Pacific Biomedical","version":"1.0","type":"link"}