{"product_id":"double-swivel-elbow-with-bronc-120-cs","title":"Double Swivel Elbow with Bronchoscopy Port, 1898000, 120\/Case","description":"\u003cdiv class=\"pbm-product pbm-faq-aligned\"\u003e \u003ch2 style=\"text-align: center;\"\u003eIntersurgical Double Swivel Elbow with Bronchoscopy Port, Double Flip Top Cap with Seal (1898000)\u003c\/h2\u003e \u003cdiv class=\"pbm-lead\"\u003eThe \u003cstrong\u003eIntersurgical Double Swivel Elbow with Double Flip Top Cap with Seal (code 1898000)\u003c\/strong\u003e is a 15 mm OD by 22 mm OD\/15 mm ID double swivel elbow, sold 120 per case in boxes of 30.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e Opening the first tab on the cap allows a fiber optic bronchoscope to be introduced while airway pressure is maintained, and opening the second tab allows suctioning.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e Both connections swivel for added mobility at the patient connection, and the port caps are tethered so they cannot be lost in use.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e Pacific Biomedical supplies the Intersurgical 1898000 by the case of 120. \u003c\/div\u003e \u003ch2\u003eProduct Highlights:\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003eBronchoscopy port:\u003c\/strong\u003e The first tab of the double flip top cap with seal admits a fiber optic bronchoscope while airway pressure is maintained.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e \u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSuction access:\u003c\/strong\u003e The second tab opens for suctioning when required.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e The cap covers 7.6 mm and 9.5 mm applications.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e \u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eDouble swivel:\u003c\/strong\u003e A 15 mm OD swivel and a 22 mm OD\/15 mm ID swivel give added mobility at the patient connection.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e \u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eTethered caps:\u003c\/strong\u003e Intersurgical port caps are tethered to the connector to prevent loss or misplacement in use.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e \u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eCompressible volume:\u003c\/strong\u003e 12 ml.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e \u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSingle use, no natural rubber latex:\u003c\/strong\u003e Single use, supplied non-sterile, and labeled as not made with natural rubber latex.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eWhat's Included:\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e120 x Intersurgical double swivel elbow, 15 mm OD, double flip top cap with seal, 22 mm OD\/15 mm ID (1898000), packed 30 per box\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eSpecifications:\u003c\/h2\u003e \u003ctable class=\"pbm-table\"\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth style=\"width:38%;\"\u003eManufacturer\u003c\/th\u003e \u003ctd\u003eIntersurgical Incorporated\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eManufacturer code (MPN)\u003c\/th\u003e \u003ctd\u003e1898000\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003ePacific Biomedical SKU\u003c\/th\u003e \u003ctd\u003eINT-1898000\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eDescription\u003c\/th\u003e \u003ctd\u003eDouble swivel elbow 15 OD, double flip top cap with seal, 22 OD\/15 ID\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eConnectors\u003c\/th\u003e \u003ctd\u003e15 mm OD (15M) swivel and 22 mm OD\/15 mm ID (22M\/15F) swivel\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003ePort\u003c\/th\u003e \u003ctd\u003eDouble flip top cap with seal: bronchoscope tab and suction tab, covers 7.6 mm and 9.5 mm applications\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eCompressible volume\u003c\/th\u003e \u003ctd\u003e12 ml\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eUse\u003c\/th\u003e \u003ctd\u003eSingle use\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eSterility\u003c\/th\u003e \u003ctd\u003eNon-sterile (sterile version: 1898000S, 15 per box)\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-4\"\u003e4\u003c\/a\u003e\u003c\/sup\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eNatural rubber latex\u003c\/th\u003e \u003ctd\u003eLabeled as not made with natural rubber latex\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003ePack\u003c\/th\u003e \u003ctd\u003e30 per box, 120 per case\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eGTIN\u003c\/th\u003e \u003ctd\u003eCase of 120: 05030267116799; box of 30: 05030267116782; unit: 05030267056026\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eFDA product code\u003c\/th\u003e \u003ctd\u003eBZA, connector, airway (extension)\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eGMDN term\u003c\/th\u003e \u003ctd\u003eStraight\/elbow breathing circuit connector, single-use\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e \u003ch2\u003eUse Cases:\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eFiber optic bronchoscopy through the airway connection while airway pressure is maintained\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e \u003cli\u003eSuctioning through the second tab of the cap when required\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e \u003cli\u003eAdding mobility at the patient connection of a breathing system\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e \u003cli\u003eAs a straight\/elbow breathing circuit connector (GMDN 61346), connecting a breathing circuit breathing tube to an endotracheal tube, anesthesia face mask or other non-sampling breathing circuit component\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eRelated products:\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"\/products\/int-1897000\"\u003eIntersurgical Double Swivel Elbow, 15 mm OD, 22 mm OD\/15 mm ID, without port (1897000)\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"\/products\/int-3511000\"\u003eIntersurgical Flexible Straight Catheter Mount, 22F-22M\/15F (3511000)\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"\/products\/vyaire-adult-circuit-w-o-peep-22mm-spu-10-per-case\"\u003eVyaire LTV Adult Circuit without PEEP, 22 mm (29657-001)\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"\/collections\/ventilation-circuit-accessories\"\u003eAll ventilator circuit accessories\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eFrequently Asked Questions:\u003c\/h2\u003e \u003cdetails\u003e\u003csummary\u003eWhat is a double swivel elbow with a bronchoscopy port used for?\u003c\/summary\u003e\u003cp\u003eIt gives added mobility at the patient connection and a sealed access port.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e On 1898000, the first tab of the cap admits a fiber optic bronchoscope while airway pressure is maintained, and the second tab opens for suctioning.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e \u003cdetails\u003e\u003csummary\u003eHow does the double flip top cap with seal work?\u003c\/summary\u003e\u003cp\u003eOpen the first tab to introduce a fiber optic bronchoscope while airway pressure is maintained. Open the second tab to suction if required.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e The cap covers 7.6 mm and 9.5 mm applications.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e \u003cdetails\u003e\u003csummary\u003eWhat connector sizes does Intersurgical 1898000 have?\u003c\/summary\u003e\u003cp\u003eA 15 mm OD (15M) swivel connector and a 22 mm OD\/15 mm ID (22M\/15F) swivel connector.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e \u003cdetails\u003e\u003csummary\u003eWhat is the difference between Intersurgical 1897000, 1898000 and 1899000?\u003c\/summary\u003e\u003cp\u003eAll three are 15 mm OD by 22 mm OD\/15 mm ID double swivel elbows.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e 1897000 has no port, 1899000 has a flip top cap with a 7.6 mm port for standard 7.6 mm probes or suctioning, and 1898000 has the double flip top cap with seal for bronchoscopy and suctioning.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e See the \u003ca href=\"\/products\/int-1897000\"\u003e1897000 double swivel elbow\u003c\/a\u003e.\u003c\/p\u003e\u003c\/details\u003e \u003cdetails\u003e\u003csummary\u003eWhat does the Intersurgical 1898000 connect to?\u003c\/summary\u003e\u003cp\u003e1898000 is classified as a straight\/elbow breathing circuit connector (GMDN 61346), the device category that creates a direct connection between a breathing circuit breathing tube and an endotracheal tube, anesthesia face mask or other non-sampling breathing circuit component.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e On 1898000 the 15 mm OD and 22 mm OD\/15 mm ID connectors both swivel\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e, and the cap gives bronchoscope and suction access.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e \u003cdetails\u003e\u003csummary\u003eAre the port caps attached to the elbow?\u003c\/summary\u003e\u003cp\u003eYes. Intersurgical port caps are tethered to the connectors to prevent loss or misplacement in use.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e \u003cdetails\u003e\u003csummary\u003eWhat is the compressible volume of the 1898000 elbow?\u003c\/summary\u003e\u003cp\u003e12 ml.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e \u003cdetails\u003e\u003csummary\u003eIs the 1898000 double swivel elbow sterile?\u003c\/summary\u003e\u003cp\u003eNo. 1898000 is supplied non-sterile.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e The sterile version is 1898000S, 15 per box.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-4\"\u003e4\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e \u003cdetails\u003e\u003csummary\u003eIs the Intersurgical 1898000 latex free and single use?\u003c\/summary\u003e\u003cp\u003eIt is single use and is labeled as not made with natural rubber latex.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e \u003cdetails\u003e\u003csummary\u003eHow many elbows come in a case?\u003c\/summary\u003e\u003cp\u003e120 per case, packed 30 per box.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e \u003cdetails\u003e\u003csummary\u003eWhat GTIN does the case of 120 carry?\u003c\/summary\u003e\u003cp\u003e05030267116799 for the case of 120. The box of 30 is 05030267116782, and the unit is 05030267056026.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e \u003cdetails\u003e\u003csummary\u003eHow do I order by purchase order or get facility pricing?\u003c\/summary\u003e\u003cp\u003eAdd it to your cart on this page, or contact CustomerService@pacificbiomedical.com or 844.436.3526 for a purchase order or facility pricing.\u003c\/p\u003e\u003c\/details\u003e \u003cdiv class=\"pbm-refs\"\u003e\u003cdetails\u003e\u003csummary\u003eReferences\u003c\/summary\u003e\u003col\u003e \u003cli id=\"ref-1\"\u003eIntersurgical Incorporated. Double swivel elbows (product range page: double flip top cap with seal function, tethered port caps, 1897000, 1898000 and 1899000, box quantity 30, case quantity 120). Accessed October 30, 2026. \u003ca href=\"https:\/\/us.intersurgical.com\/products\/airway-management\/double-swivel-elbows\" rel=\"noopener\" target=\"_blank\"\u003eus.intersurgical.com\u003c\/a\u003e.\u003c\/li\u003e \u003cli id=\"ref-2\"\u003eIntersurgical Ltd. Patient Connections product catalogue, Elbows. p 20 (double swivel elbow 1898000, 15M swivel, 22M\/15F swivel, double flip top cap with seal covering 7.6 mm and 9.5 mm applications, compressible volume 12 ml).\u003c\/li\u003e \u003cli id=\"ref-3\"\u003eUS Food and Drug Administration. Global Unique Device Identification Database (GUDID) record: Double swivel elbow 15M, double flip top cap with seal, 22M\/15F, version or model 1898000, Intersurgical Incorporated (single use, non-sterile, not made with natural rubber latex, GTIN 05030267056026, packages of 30 and 120, product code BZA, GMDN 61346 straight\/elbow breathing circuit connector single-use, in commercial distribution). Accessed October 30, 2026. \u003ca href=\"https:\/\/accessgudid.nlm.nih.gov\/devices\/05030267056026\" rel=\"noopener\" target=\"_blank\"\u003eaccessgudid.nlm.nih.gov\u003c\/a\u003e.\u003c\/li\u003e \u003cli id=\"ref-4\"\u003eIntersurgical Ltd. Double swivel elbows (international product range page: 1898000S sterile, box quantity 15). Accessed October 30, 2026.\u003c\/li\u003e \u003c\/ol\u003e\u003c\/details\u003e\u003c\/div\u003e \u003cp\u003e\u003cem\u003eFollow the Intersurgical instructions for use and your facility's policy for airway connection, bronchoscopy and suctioning.\u003c\/em\u003e\u003c\/p\u003e \u003c\/div\u003e","brand":"Intersurgical Inc.","offers":[{"title":"Default Title","offer_id":52800198082871,"sku":"INT-1898000","price":226.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/7415\/6599\/files\/intersurgical-1898000-double-swivel-elbow-bronchoscopy-port.jpg?v=1793390075","url":"https:\/\/shop.pacificbiomedical.com\/products\/double-swivel-elbow-with-bronc-120-cs","provider":"Pacific Biomedical","version":"1.0","type":"link"}