{"product_id":"babi-plus-ntest-lung-kit-1-set-r90-r145-r300-r600","title":"Babi.Plus nTest Neonatal Test Lung Kit, R90, R145, R300, R600","description":"\u003c!-- Preferred URL: https:\/\/shop.pacificbiomedical.com\/products\/babi-plus-ntest-lung-kit-1-set-r90-r145-r300-r600 --\u003e\n\u003cdiv class=\"pbm-product pbm-faq-aligned\"\u003e\n\u003ch2 style=\"text-align: center;\"\u003eBabi.Plus nTest Lung Kit, Neonatal Test Lungs R90, R145, R300 and R600 (MPN 2010K)\u003c\/h2\u003e\n\u003cdiv class=\"pbm-lead\"\u003eThe \u003cstrong\u003eBabi.Plus nTest Lung Kit (MPN 2010K)\u003c\/strong\u003e is a set of four neonatal test lungs for infant and neonatal ventilator support devices, one nTest Lung at each resistance: R90, R145, R300 and R600.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e Each nTest Lung is a neonatal lung simulator with two silicone lungs on a Y connector, used for training, demonstration and ventilator verification testing with infant and neonatal ventilator support devices.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e The four resistances, 90, 145, 300 and 600 cm H2O\/L\/s at 1 L\/s, let one kit simulate different lung functions.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/div\u003e\n\u003ch2\u003eProduct Highlights:\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFour resistances in one kit:\u003c\/strong\u003e One nTest Lung set each at R90, R145, R300 and R600.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTwo lungs on a Y connector:\u003c\/strong\u003e Two individual silicone lungs on a Y connector mimic anatomical design.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eColor coded by resistance:\u003c\/strong\u003e Each test lung is color coded around the neck, so the individual lung resistance is easy to identify: R90 green, R145 yellow, R300 blue and R600 pink.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNeonatal volumes:\u003c\/strong\u003e 25 mL per silicone bag, 50 mL total, with compliance of approximately 2.0 mL\/cm H2O.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard ISO connections:\u003c\/strong\u003e The Y connector has a 15\/10 mm port, the straight connector is 10 mm OD, and the pressure monitoring port is 4.3 mm ID.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLight and portable:\u003c\/strong\u003e The nTest Lung weighs approximately 43 grams.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat's Included:\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Babi.Plus nTest Lung, R90 (90 cm H2O\/L\/s)\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n  \u003cli\u003e1 x Babi.Plus nTest Lung, R145 (145 cm H2O\/L\/s)\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n  \u003cli\u003e1 x Babi.Plus nTest Lung, R300 (300 cm H2O\/L\/s)\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n  \u003cli\u003e1 x Babi.Plus nTest Lung, R600 (600 cm H2O\/L\/s)\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eResistance Chart:\u003c\/h2\u003e\n\u003ctable class=\"pbm-table\"\u003e\u003ctbody\u003e\n  \u003ctr\u003e\n\u003cth style=\"width:22%;\"\u003enTest Lung\u003c\/th\u003e\n\u003cth\u003eResistance at 1 L\/s\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/th\u003e\n\u003cth\u003eInner diameter\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/th\u003e\n\u003cth\u003eColor\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eR90\u003c\/td\u003e\n\u003ctd\u003e90 cm H2O\/L\/s\u003c\/td\u003e\n\u003ctd\u003e3.5 mm\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eR145\u003c\/td\u003e\n\u003ctd\u003e145 cm H2O\/L\/s\u003c\/td\u003e\n\u003ctd\u003e3.0 mm\u003c\/td\u003e\n\u003ctd\u003eYellow\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/rl-2010-300\"\u003eR300\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e300 cm H2O\/L\/s\u003c\/td\u003e\n\u003ctd\u003e2.5 mm\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eR600\u003c\/td\u003e\n\u003ctd\u003e600 cm H2O\/L\/s\u003c\/td\u003e\n\u003ctd\u003e2.0 mm\u003c\/td\u003e\n\u003ctd\u003ePink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eSpecifications:\u003c\/h2\u003e\n\u003ctable class=\"pbm-table\"\u003e\u003ctbody\u003e\n  \u003ctr\u003e\n\u003cth style=\"width:38%;\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eBabi.Plus, a registered trademark of GaleMed Corporation\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eSupplier\u003c\/th\u003e\n\u003ctd\u003eRespiralogics, a Global Respiratory Solutions, Inc. company, Reno NV\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\n\u003ctd\u003e2010K\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePacific Biomedical SKU\u003c\/th\u003e\n\u003ctd\u003eRL-2010K\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003ctd\u003eNeonatal lung simulator kit, four nTest Lungs\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eResistances\u003c\/th\u003e\n\u003ctd\u003e90, 145, 300 and 600 cm H2O\/L\/s at 1 L\/s flow\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eTidal volume\u003c\/th\u003e\n\u003ctd\u003e25 mL each silicone bag, 50 mL total\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eApproximately 1.0 mL\/cm H2O per bag (2.0 mL\/cm H2O for the two-lung set)\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eInterface connector\u003c\/th\u003e\n\u003ctd\u003eY connector with 15\/10 mm port\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eStraight connector\u003c\/th\u003e\n\u003ctd\u003e10 mm OD\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003ePressure monitoring port\u003c\/th\u003e\n\u003ctd\u003e4.3 mm ID\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eLung material\u003c\/th\u003e\n\u003ctd\u003eSilicone\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eApproximately 43 grams\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eStorage\u003c\/th\u003e\n\u003ctd\u003enTest Lung line packaged in a zippered canvas bag\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eUse Cases:\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eVentilator verification testing on infant and neonatal ventilator support devices\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n  \u003cli\u003eTraining and product demonstration with infant and neonatal ventilator support devices\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\n\u003c\/li\u003e\n  \u003cli\u003eShowing how one ventilator setting behaves across four different airway resistances\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated products:\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"\/products\/rl-2010-300\"\u003eBabi.Plus nTest Lung, Neonatal, R300 Resistance (single)\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/products\/rl-1000\"\u003eBabi.Plus Bubble PAP Valve, 0 to 10 cm H2O\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/products\/rl-2005\"\u003eVenti.Plus Test Lung, 0.5 L, Pediatric\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/products\/rl-2000\"\u003eVenti.Plus Test Lung, 1.0 L, Adult\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/collections\/test-lungs\"\u003eAll test lungs\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions:\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat is in the Babi.Plus nTest Lung Kit?\u003c\/summary\u003e\u003cp\u003eFour nTest Lungs, one at each resistance: R90, R145, R300 and R600.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e Each nTest Lung is two silicone lungs on a Y connector.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat do R90, R145, R300 and R600 mean?\u003c\/summary\u003e\u003cp\u003eThey are the airway resistance of each test lung in cm H2O\/L\/s at 1 L\/s flow: 90, 145, 300 and 600.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e Each value is set by a different inner diameter, from 3.5 mm on the R90 to 2.0 mm on the R600.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eHow do I tell the four test lungs apart?\u003c\/summary\u003e\u003cp\u003eEach test lung is color coded around the neck.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e R90 is green, R145 is yellow, R300 is blue and R600 is pink.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat is the tidal volume and compliance of the nTest Lung?\u003c\/summary\u003e\u003cp\u003e25 mL per silicone bag, 50 mL total, with compliance of approximately 2.0 mL\/cm H2O for the two-lung set.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e That is 1.0 mL\/cm H2O per bag.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e Compliance is the volume the test lung takes in for each cm H2O of pressure applied.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat is a test lung?\u003c\/summary\u003e\u003cp\u003eA test lung is a lung simulator connected to a ventilator in place of a patient, for training, demonstration and ventilator verification testing. The nTest Lung is a neonatal lung simulator built for infant and neonatal ventilator support devices.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat is a neonatal test lung used for?\u003c\/summary\u003e\u003cp\u003eTraining, demonstration and ventilator verification testing with infant and neonatal ventilator support devices.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat is test lung resistance?\u003c\/summary\u003e\u003cp\u003eResistance is the pressure drop across the test lung airway for each liter per second of flow, stated in cm H2O\/L\/s. The nTest Lung sets it by inner diameter, from 90 cm H2O\/L\/s on the R90 to 600 cm H2O\/L\/s on the R600.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-2\"\u003e2\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eHow do I connect a test lung to a ventilator?\u003c\/summary\u003e\u003cp\u003eThe nTest Lung interface is a Y connector with a 15\/10 mm port, and a 4.3 mm ID port allows pressure monitoring at the test lung.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e Follow the ventilator's test procedure and your facility's policy.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhich test lung do I need for infant, pediatric or adult ventilators?\u003c\/summary\u003e\u003cp\u003eFor infant and neonatal ventilator support devices, the nTest Lung, 50 mL total across two bags.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e For a pediatric lung, the \u003ca href=\"\/products\/rl-2005\"\u003eVenti.Plus Test Lung 0.5 L\u003c\/a\u003e, and for an adult lung, the \u003ca href=\"\/products\/rl-2000\"\u003eVenti.Plus Test Lung 1.0 L\u003c\/a\u003e.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-3\"\u003e3\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eHow is the kit different from the single R300 nTest Lung?\u003c\/summary\u003e\u003cp\u003eThe \u003ca href=\"\/products\/rl-2010-300\"\u003esingle nTest Lung\u003c\/a\u003e is one R300 test lung, part 2010.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e The kit adds R90, R145 and R600, so all four resistances are on hand.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWho is behind the Babi.Plus brand?\u003c\/summary\u003e\u003cp\u003eBabi.Plus is a registered trademark of GaleMed Corporation. Respiralogics, a Global Respiratory Solutions, Inc. company in Reno, Nevada, publishes the nTest Lung product page and catalog sheet C2010.5.\u003csup class=\"pbm-cite\"\u003e\u003ca href=\"#ref-1\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eHow do I order by purchase order or get facility pricing?\u003c\/summary\u003e\u003cp\u003eAdd it to your cart on this page, or contact CustomerService@pacificbiomedical.com or 844.436.3526 for a purchase order or facility pricing.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdiv class=\"pbm-refs\"\u003e\u003cdetails\u003e\u003csummary\u003eReferences\u003c\/summary\u003e\u003col\u003e\n\u003cli id=\"ref-1\"\u003eRespiralogics, a Global Respiratory Solutions, Inc. company. Babi.Plus nTest Lung product page and catalog sheet C2010.5 (neonatal lung simulator, two silicone lungs and a Y connector, color coded around the neck by resistance, training, demonstration and ventilator verification testing, features, specifications, ordering information including 2010K nTest Lung Kit with one test lung set each R90, R145, R300 and R600, Babi.Plus trademark of GaleMed Corporation). \u003ca href=\"https:\/\/www.respiralogics.com\/content\/babi_ntest_lung.html\" rel=\"noopener\" target=\"_blank\"\u003erespiralogics.com\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli id=\"ref-2\"\u003eGaleMed Corporation. Babi.Plus nTest Lung brochure, 2025 (resistance values 90, 145, 300 and 600 cm H2O\/L\/s at 1 L\/s set by inner diameters 3.5, 3.0, 2.5 and 2.0 mm, color rings by resistance, compliance 1.0 mL\/cm H2O per bag, 25 mL per bag). \u003ca href=\"https:\/\/www.galemed.com\/storage\/media\/babi\/pdf\/2025-nTest%20Lung%20Brochure.pdf\" rel=\"noopener\" target=\"_blank\"\u003egalemed.com\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli id=\"ref-3\"\u003eRespiralogics, a Global Respiratory Solutions, Inc. company. Venti.Plus Test Lung product page (1.0 L silicone bag simulates an adult lung, 0.5 L silicone bag simulates a pediatric lung, training, demonstration and ventilator verification testing). \u003ca href=\"https:\/\/www.respiralogics.com\/content\/venti_test_lung.html\" rel=\"noopener\" target=\"_blank\"\u003erespiralogics.com\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ol\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003eUse the nTest Lung for training, demonstration and ventilator verification testing. Follow the ventilator's test procedure and your facility's policy.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n","brand":"Respiralogics, LLC","offers":[{"title":"Default Title","offer_id":52800198148407,"sku":"RL-2010K","price":799.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/7415\/6599\/files\/babi-plus-ntest-lung-kit-2010k-carry-bag.jpg?v=1793367634","url":"https:\/\/shop.pacificbiomedical.com\/products\/babi-plus-ntest-lung-kit-1-set-r90-r145-r300-r600","provider":"Pacific Biomedical","version":"1.0","type":"link"}