{"product_id":"arrow®-t-pod-responder-pelvic-stabilization-device","title":"T-POD (Trauma Pelvic Orthotic Device) Responder Pelvic Stabilization Device","description":"\u003c!--\n============================================================\nPACIFIC BIOMEDICAL — SHOPIFY PRODUCT LISTING\nProduct: Arrow T-POD Responder Pelvic Stabilization Device (Teleflex)\nManufacturer Item #: T-PODR (Responder, orange) | Combat variant: T-PODC (black)\n------------------------------------------------------------\nSHOPIFY SETUP (copy into the matching fields):\n\n  Product title:  Arrow T-POD Responder Pelvic Stabilization Device\n  Vendor:         Teleflex\n  Suggested SKU:  TF-T-PODR         [CONFIRM your Teleflex SKU convention]\n  Suggested handle: arrow-t-pod-responder   [CONFIRM at publish; links below use it]\n  Collection:     Pelvic Binders (\/collections\/pelvic-binders)  [exists]\n  Tags:           pelvic binder, pelvic stabilization device, T-POD, T-PODR, Teleflex,\n                  Arrow, circumferential compression, PCCD, pelvic fracture, trauma, EMS,\n                  HEMS, tactical, TCCC, radiolucent, latex-free, single-use, Rx\n\n  SEO TITLE (61 chars):\n  Arrow T-POD Responder Pelvic Binder (T-PODR) | Teleflex Trauma\n\n  SEO DESCRIPTION (145 chars):\n  Arrow T-POD Responder (T-PODR): Teleflex pulley-driven pelvic binder for suspected unstable pelvic fractures. Radiolucent, latex-free, single-use.\n\n  IMAGE ALT TEXT:\n  Teleflex Arrow T-POD Responder T-PODR orange pelvic stabilization binder with pulley system - Pacific Biomedical\n\n  \u003e\u003e\u003e BEFORE PUBLISH, set these (left as placeholders on purpose):\n      {{PRICE}}      — set your sell price (also fills the Shopify price field)\n      {{IMAGE_URL}}  — your hosted product image URL (for schema)\n      handle\/SKU     — confirm per notes above\n      NSN            — none verified for the T-POD; the 6515-01-560-0290 you may find\n                       belongs to the competitor \"PelvicBinder\" brand, NOT the T-POD.\n                       Add a real T-POD NSN only if Teleflex\/your rep confirms one.\n============================================================\n--\u003e\n\u003cstyle\u003e\n    .pbm-product{--pbm-blue:#1E4C8A;--pbm-accent:#2563EB;--pbm-surface:#EFF6FF;--pbm-border:#CBD5E1;--pbm-text:#1F2937;--pbm-text2:#334155;color:var(--pbm-text);font-family:-apple-system,BlinkMacSystemFont,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;line-height:1.6;max-width:900px;margin:0 auto;}\n    .pbm-product h2{color:var(--pbm-blue);font-size:1.35rem;margin:2rem 0 .75rem;padding-bottom:.4rem;border-bottom:2px solid var(--pbm-surface);text-align:center;}\n    .pbm-product h3{color:var(--pbm-blue);font-size:1.05rem;margin:.25rem 0 .4rem;}\n    .pbm-product p{margin:.6rem 0;color:var(--pbm-text2);}\n    .pbm-product a{color:var(--pbm-accent);text-decoration:none;font-weight:600;}\n    .pbm-product a:hover{text-decoration:underline;}\n    .pbm-lead{background:var(--pbm-surface);border:1px solid var(--pbm-border);border-radius:10px;padding:1.25rem 1.5rem;margin-bottom:1.25rem;}\n    .pbm-lead p{color:var(--pbm-text);font-size:1.02rem;margin:0;}\n    .pbm-facts{display:grid;grid-template-columns:repeat(auto-fit,minmax(145px,1fr));gap:.6rem;margin:1.25rem 0;}\n    .pbm-fact{background:var(--pbm-surface);border:1px solid var(--pbm-border);border-radius:8px;padding:.75rem .85rem;text-align:center;}\n    .pbm-product .pbm-fact-label{display:block;font-size:.7rem;font-weight:600;letter-spacing:.07em;text-transform:uppercase;color:var(--pbm-text2);margin-bottom:.3rem;}\n    .pbm-product .pbm-fact-value{display:block;font-size:.92rem;font-weight:600;color:var(--pbm-blue);line-height:1.35;}\n    \/* list-style forced off — themes re-add native bullets alongside the blue :before dots *\/\n    .pbm-product .pbm-highlights{list-style:none !important;padding-left:0 !important;margin:.5rem 0;}\n    .pbm-product .pbm-highlights li{list-style:none !important;position:relative;padding:.5rem 0 .5rem 1.5rem;border-bottom:1px solid var(--pbm-surface);color:var(--pbm-text2);}\n    .pbm-product .pbm-highlights li::marker{content:\"\";}\n    .pbm-product .pbm-highlights li:before{content:\"\";position:absolute;left:0;top:.95rem;width:8px;height:8px;border-radius:50%;background:var(--pbm-accent);}\n    .pbm-clinical{background:#fff;border:1px solid var(--pbm-border);border-left:4px solid var(--pbm-accent);border-radius:8px;padding:1rem 1.25rem;margin:1.25rem 0;}\n    .pbm-clinical h3{margin-top:0;}\n    .pbm-clinical p{font-size:.95rem;}\n    .pbm-cite{font-size:.7em;vertical-align:super;line-height:0;}\n    .pbm-product .pbm-cite a{color:var(--pbm-accent);font-weight:600;text-decoration:none;}\n    .pbm-refs{background:#fff;border:1px solid var(--pbm-border);border-radius:10px;padding:1rem 1.25rem;margin:1.25rem 0;}\n    .pbm-refs h3{margin-top:0;text-align:center;}\n    .pbm-refs ol{margin:.5rem 0 0;padding-left:1.4rem;}\n    .pbm-refs li{font-size:.85rem;color:var(--pbm-text2);margin-bottom:.55rem;line-height:1.5;}\n    .pbm-refs .pbm-refnote{font-size:.8rem;color:var(--pbm-text2);margin-top:.85rem;}\n    .pbm-table{width:100%;border-collapse:collapse;margin:.75rem 0;font-size:.92rem;}\n    .pbm-table th,.pbm-table td{border:1px solid var(--pbm-border);padding:.6rem .8rem;text-align:left;}\n    .pbm-product .pbm-table th{background:var(--pbm-blue) !important;color:#ffffff !important;font-weight:600;}\n    .pbm-product .pbm-table th *{color:#ffffff !important;}\n    .pbm-table tr:nth-child(even) td{background:var(--pbm-surface);}\n    .pbm-table td:first-child{font-weight:600;color:var(--pbm-blue);width:38%;}\n    .pbm-compat{background:var(--pbm-surface);border:1px solid var(--pbm-border);border-radius:10px;padding:1.1rem 1.35rem;margin:1rem 0;}\n    .pbm-compat h3{margin-top:0;text-align:center;}\n    .pbm-product .pbm-compat ul{list-style:none !important;padding-left:0 !important;margin:.5rem 0 0;}\n    .pbm-product .pbm-compat li::marker{content:\"\";}\n    .pbm-compat li{padding:.5rem 0;border-bottom:1px solid #fff;}\n    .pbm-compat li:last-child{border-bottom:none;}\n    .pbm-cards{display:grid;grid-template-columns:repeat(auto-fit,minmax(190px,1fr));gap:1rem;margin:.75rem 0;}\n    .pbm-card{background:#fff;border:1px solid var(--pbm-border);border-top:3px solid var(--pbm-accent);border-radius:10px;padding:1rem 1.1rem;}\n    .pbm-card h3{margin-top:0;font-size:1rem;}\n    .pbm-card p{font-size:.9rem;margin:.35rem 0 0;}\n    .pbm-faq details{border:1px solid var(--pbm-border);border-radius:8px;margin:.5rem 0;overflow:hidden;background:#fff;}\n    .pbm-product .pbm-faq summary{cursor:pointer;padding:.85rem 1.1rem;font-weight:600;color:var(--pbm-blue);background:var(--pbm-surface);list-style:none !important;}\n    .pbm-product .pbm-faq summary::marker{content:\"\";}\n    .pbm-faq summary::-webkit-details-marker{display:none;}\n    .pbm-faq summary:after{content:\"+\";float:right;color:var(--pbm-accent);font-weight:700;}\n    .pbm-faq details[open] summary:after{content:\"–\";}\n    .pbm-faq .pbm-answer{padding:.85rem 1.1rem;color:var(--pbm-text2);font-size:.94rem;}\n    .pbm-order{background:var(--pbm-blue);border-radius:10px;padding:1.25rem 1.5rem;margin-top:1.5rem;text-align:center;}\n    .pbm-product .pbm-order,.pbm-product .pbm-order h3,.pbm-product .pbm-order p,.pbm-product .pbm-order a,.pbm-product .pbm-order strong{color:#ffffff !important;}\n    .pbm-order p{margin:.35rem 0;}\n    .pbm-order a{text-decoration:underline;}\n    .pbm-order .pbm-phone{font-size:1.25rem;font-weight:700;}\n  \u003c\/style\u003e\n\u003cdiv class=\"pbm-product\"\u003e\n\u003c!-- 1. LEAD OVERVIEW --\u003e\n\u003cdiv class=\"pbm-lead\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eArrow® T-POD® Responder Pelvic Stabilization Device\u003c\/strong\u003e from Teleflex applies circumferential compression to the pelvis in patients with a suspected pelvic fracture — reducing pelvic volume to help control blood loss and pain. Its unique pulley system lets a single EMS professional apply controlled, adjustable compression quickly, and its one-size-fits-all design trims to fit almost any patient. With no metallic parts, it stays in place through X-ray, CT, and MRI.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-1\"\u003e1\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- 2. AT-A-GLANCE SPEC GRID --\u003e\n\u003cdiv class=\"pbm-facts\"\u003e\n\u003cdiv class=\"pbm-fact\"\u003e\n\u003cspan class=\"pbm-fact-label\"\u003eItem #\u003c\/span\u003e\u003cspan class=\"pbm-fact-value\"\u003eT-PODR\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pbm-fact\"\u003e\n\u003cspan class=\"pbm-fact-label\"\u003eManufacturer\u003c\/span\u003e\u003cspan class=\"pbm-fact-value\"\u003eTeleflex (Arrow)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pbm-fact\"\u003e\n\u003cspan class=\"pbm-fact-label\"\u003eMechanism\u003c\/span\u003e\u003cspan class=\"pbm-fact-value\"\u003ePulley compression\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pbm-fact\"\u003e\n\u003cspan class=\"pbm-fact-label\"\u003eSizing\u003c\/span\u003e\u003cspan class=\"pbm-fact-value\"\u003eOne size fits all\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pbm-fact\"\u003e\n\u003cspan class=\"pbm-fact-label\"\u003eImaging\u003c\/span\u003e\u003cspan class=\"pbm-fact-value\"\u003eX-ray, CT, MRI\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pbm-fact\"\u003e\n\u003cspan class=\"pbm-fact-label\"\u003eUse\u003c\/span\u003e\u003cspan class=\"pbm-fact-value\"\u003eSingle-use, Rx only\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- 3. PRODUCT HIGHLIGHTS --\u003e\n\u003ch2\u003eProduct Highlights\u003c\/h2\u003e\n\u003cul class=\"pbm-highlights\"\u003e\n\u003cli\u003ePulley system delivers adjustable circumferential compression that reduces pelvic volume, which may reduce blood loss and pain.\u003c\/li\u003e\n\u003cli\u003eShown to reduce symphyseal diastasis by 60% (p = 0.01) in patients with unstable pelvic fractures and signs of shock.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-2\"\u003e2\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eFast, single-provider application: in an independent equipment review, trained users applied it correctly 100% of the time, and 78% preferred it over the comparator device.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-3\"\u003e3\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eOne-size-fits-all — trim to fit smaller patients, or join two devices together for bariatric patients.\u003c\/li\u003e\n\u003cli\u003eNo metallic parts: remains in place during X-ray, CT, and MRI, so imaging isn't delayed.\u003c\/li\u003e\n\u003cli\u003eNot made with natural rubber latex; single-use. Rx only.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- 4. CLINICAL CONTEXT (E-E-A-T; balanced, sourced) --\u003e\n\u003cdiv class=\"pbm-clinical\"\u003e\n\u003ch3\u003eClinical Context: Right Patient, Right Placement\u003c\/h3\u003e\n\u003cp\u003ePelvic ring injuries carry significant morbidity and mortality, and hemorrhagic shock occurs in roughly 10% of cases — so circumferential compression is a standard early adjunct for the hemodynamically unstable patient with a suspected unstable pelvic fracture.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-4\"\u003e4\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe evidence behind this device is specific. In 15 patients with untreated unstable pelvic fractures and signs of hypovolemic shock, the T-POD reduced symphyseal diastasis by 60% (p = 0.01), with mean arterial pressure rising from 65.3 to 81.2 mm Hg and heart rate falling from 107 to 94.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-2\"\u003e2\u003c\/a\u003e\u003c\/span\u003e In a biomechanical cadaver study of three compression devices, all closed the pelvic ring without over-reduction, but the T-POD required the lowest pulling force to achieve complete reduction at the symphysis — 43 N, versus 60 N and 112 N for the two comparators.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-5\"\u003e5\u003c\/a\u003e\u003c\/span\u003e A 2024 cadaveric comparison against the SAM Pelvic Sling II found the T-POD less susceptible to incorrect positioning; its authors concluded the results support preferred use of the T-POD for prehospital emergency pelvic stabilization.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-6\"\u003e6\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003ePlacement is decisive. The device centerline belongs over the greater trochanters, not the iliac crests. In a review of 167 radiographs with a visible binder, only 50% were positioned correctly and 39% sat too high — and high placement left a symphyseal gap averaging 22 mm greater than correct placement (p \u0026lt; 0.01).\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-7\"\u003e7\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003ePatient selection matters as much as technique. The 2025 NAEMSP position statement notes that the clinical benefit of prehospital compression devices is questionable when applied routinely, and emphasizes evidence-guided selection: reserve them for the unstable patient with a suspicious mechanism, place them correctly, avoid over-tensioning, and keep searching for other sources of bleeding rather than anchoring on the pelvis.\u003cspan class=\"pbm-cite\"\u003e\u003ca href=\"#pbm-ref-8\"\u003e8\u003c\/a\u003e\u003c\/span\u003e Applied to the right patient with correct technique, a pelvic binder remains a valuable prehospital tool. Follow your local protocol and scope of practice.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- 5. PRODUCT IDENTIFIERS --\u003e\n\u003ch2\u003eSpecifications \u0026amp; Compatibility\u003c\/h2\u003e\n\u003ctable class=\"pbm-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanism\u003c\/td\u003e\n\u003ctd\u003ePulley-based circumferential compression, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSizing\u003c\/td\u003e\n\u003ctd\u003eOne-size-fits-all; trim to fit; join two units for bariatric patients\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Site\u003c\/td\u003e\n\u003ctd\u003eCenterline over the greater trochanters \/ symphysis pubis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImaging\u003c\/td\u003e\n\u003ctd\u003eRadiolucent — no metallic parts; X-ray, CT, and MRI compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eNot made with natural rubber latex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUse\u003c\/td\u003e\n\u003ctd\u003eSingle-use; Rx only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVariants\u003c\/td\u003e\n\u003ctd\u003eResponder (T-PODR, orange); Combat (T-PODC, black)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- 7. COMPLETE-THE-SYSTEM \/ INTERNAL LINKS --\u003e\n\u003cdiv class=\"pbm-compat\"\u003e\n\u003ch3\u003eComplete the Hemorrhage-Control Setup\u003c\/h3\u003e\n\u003cp\u003eUnstable pelvic trauma rarely travels alone. Pair pelvic stabilization with layered hemorrhage control:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eJunctional \/ pelvic bleeding:\u003c\/strong\u003e \u003ca href=\"\/products\/jt400-en\"\u003eSAM Junctional Tourniquet\u003c\/a\u003e — controls inguinal and axillary hemorrhage where limb tourniquets can't reach.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHemostatic control:\u003c\/strong\u003e \u003ca href=\"\/products\/trauma-gel-for-ems\"\u003eTraumaGel Hemostatic Gel\u003c\/a\u003e — rapid, ready-to-use control of moderate to severe external bleeding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtremity hemorrhage:\u003c\/strong\u003e \u003ca href=\"\/products\/nar-30-0001\"\u003eCombat Application Tourniquet (C-A-T)\u003c\/a\u003e — the proven field tourniquet for limb bleeding in polytrauma.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- 8. WHO USES THIS --\u003e\n\u003ch2\u003eWho Uses This\u003c\/h2\u003e\n\u003cdiv class=\"pbm-cards\"\u003e\n\u003cdiv class=\"pbm-card\"\u003e\n\u003ch3\u003eGround EMS \u0026amp; Ambulance\u003c\/h3\u003e\n\u003cp\u003eFast, single-provider pelvic stabilization for suspected unstable pelvic fractures.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pbm-card\"\u003e\n\u003ch3\u003eAir Medical \/ HEMS\u003c\/h3\u003e\n\u003cp\u003eCompact, radiolucent binder that stays on through imaging and interfacility transfer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pbm-card\"\u003e\n\u003ch3\u003eFire, Rescue \u0026amp; Tactical\u003c\/h3\u003e\n\u003cp\u003eCombat variant (T-PODC) for TCCC\/TECC casualty care and austere response.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pbm-card\"\u003e\n\u003ch3\u003eHospital ED \u0026amp; Trauma\u003c\/h3\u003e\n\u003cp\u003eMaintains pelvic compression during resuscitation, X-ray, CT, and MRI.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- 9. FAQ (answer-first; ends with authenticity\/shipping\/ordering trio) --\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"pbm-faq\"\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhere should the T-POD be positioned on the pelvis?\u003c\/summary\u003e\n\u003cdiv class=\"pbm-answer\"\u003eCenter the T-POD over the greater trochanters and symphysis pubis — not the iliac crests, a common misplacement that reduces effectiveness. Trim the belt to leave a 15–20 cm gap, then draw tension with the pull tab until snug: two fingers should fit beneath it and the edges should not meet. Internally rotate the legs to complete stabilization.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs the T-POD safe for X-ray, CT, and MRI?\u003c\/summary\u003e\n\u003cdiv class=\"pbm-answer\"\u003eYes. The Arrow T-POD has no metallic parts and is radiolucent, so it can remain in place during X-ray, CT, and MRI. Imaging isn't delayed by removing and reapplying the device, and the pelvis stays stabilized throughout assessment, resuscitation, and transfer.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhen should a pelvic binder be applied — and is it \"more harm than good\"?\u003c\/summary\u003e\n\u003cdiv class=\"pbm-answer\"\u003ePelvic binders are indicated for hemodynamically unstable patients with a suspicious mechanism or suspected unstable pelvic fracture, applied correctly. The 2025 NAEMSP position statement cautions against routine, universal use and stresses careful patient selection, correct placement, and continuing to search for other bleeding sources — not abandoning binders for the right patient. Applied to patients later found to have no fracture, circumferential binding has minimal adverse effect.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat sizes does it fit? Can it be used on large or pediatric patients?\u003c\/summary\u003e\n\u003cdiv class=\"pbm-answer\"\u003eThe T-POD is one-size-fits-all. Trim the belt to fit smaller patients, or join two devices together to create an extra-large binder for bariatric patients. It can also be used for pediatric and small-adult patients as long as the greater-trochanter and symphysis landmarks can be identified for correct placement.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs this an authentic Teleflex product?\u003c\/summary\u003e\n\u003cdiv class=\"pbm-answer\"\u003eYes. Pacific Biomedical supplies genuine, factory-fresh Teleflex (Arrow) products sourced through authorized channels, shipped in original manufacturer packaging.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow fast does this ship?\u003c\/summary\u003e\n\u003cdiv class=\"pbm-answer\"\u003eIn-stock orders typically ship within one business day. For expedited shipping, current lead times, or freight on bulk orders, contact us at \u003ca href=\"mailto:CustomerService@pacificbiomedical.com\"\u003eCustomerService@pacificbiomedical.com\u003c\/a\u003e or 844.436.3526.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow do I order the Responder or Combat variant, request a quote, or set up an account?\u003c\/summary\u003e\n\u003cdiv class=\"pbm-answer\"\u003eAdd the item to your cart to order the Responder (T-PODR). The black Combat variant (T-PODC) is also available — contact us to order it, or for volume pricing, GPO\/contract pricing, agency purchase orders, and net terms. Reach us at \u003ca href=\"mailto:CustomerService@pacificbiomedical.com\"\u003eCustomerService@pacificbiomedical.com\u003c\/a\u003e or 844.436.3526.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c!-- 10. REFERENCES (AMA format, numbered by order of first appearance) --\u003e\n\u003cdiv class=\"pbm-refs\"\u003e\n\u003ch3\u003eReferences\u003c\/h3\u003e\n\u003col\u003e\n\u003cli id=\"pbm-ref-1\"\u003eTeleflex. Arrow T-POD pelvic stabilization device. Accessed July 22, 2026. https:\/\/teleflex.com\/usa\/en\/product-areas\/emergency-medicine\/trauma\/arrow-t-pod\/index.html\u003c\/li\u003e\n\u003cli id=\"pbm-ref-2\"\u003eTan ECTH, van Stigt SFL, van Vugt AB. Effect of a new pelvic stabilizer (T-POD) on reduction of pelvic volume and haemodynamic stability in unstable pelvic fractures. \u003cem\u003eInjury\u003c\/em\u003e. 2010;41(12):1239-1243. doi:10.1016\/j.injury.2010.03.013\u003c\/li\u003e\n\u003cli id=\"pbm-ref-3\"\u003eBryson DJ, Davidson R, Mackenzie R. Pelvic circumferential compression devices (PCCDs): a best evidence equipment review. \u003cem\u003eEur J Trauma Emerg Surg\u003c\/em\u003e. 2012;38(4):439-442. doi:10.1007\/s00068-012-0180-3\u003c\/li\u003e\n\u003cli id=\"pbm-ref-4\"\u003eHalawi MJ. Pelvic ring injuries: emergency assessment and management. \u003cem\u003eJ Clin Orthop Trauma\u003c\/em\u003e. 2015;6(4):252-258. doi:10.1016\/j.jcot.2015.08.002\u003c\/li\u003e\n\u003cli id=\"pbm-ref-5\"\u003eKnops SP, Schep NWL, Spoor CW, et al. Comparison of three different pelvic circumferential compression devices: a biomechanical cadaver study. \u003cem\u003eJ Bone Joint Surg Am\u003c\/em\u003e. 2011;93(3):230-240. doi:10.2106\/JBJS.J.00084\u003c\/li\u003e\n\u003cli id=\"pbm-ref-6\"\u003ePrivalov M, Junge M, Jung MK, et al. Comparison of T-POD and SAM Pelvic Sling II and the influence of attachment level in the initial management of unstable pelvic type C injuries: a cadaveric study. \u003cem\u003eInt J Emerg Med\u003c\/em\u003e. 2024;17(1):34. doi:10.1186\/s12245-024-00610-8\u003c\/li\u003e\n\u003cli id=\"pbm-ref-7\"\u003eBonner TJ, Eardley WGP, Newell N, et al. Accurate placement of a pelvic binder improves reduction of unstable fractures of the pelvic ring. \u003cem\u003eJ Bone Joint Surg Br\u003c\/em\u003e. 2011;93(11):1524-1528. doi:10.1302\/0301-620X.93B11.27023\u003c\/li\u003e\n\u003cli id=\"pbm-ref-8\"\u003eLyng JW, Corsa JG, Raetzke BD, et al. Prehospital trauma compendium: evaluation and management of suspected pelvis fractures — an NAEMSP position statement and resource document. \u003cem\u003ePrehosp Emerg Care\u003c\/em\u003e. 2025:1-35. doi:10.1080\/10903127.2025.2540420\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"pbm-refnote\"\u003ePeer-reviewed citations located via PubMed. This information is provided for clinical education and does not replace your agency's protocols, medical direction, or the manufacturer's Instructions for Use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- 11. ORDERING CTA --\u003e\n\u003cdiv class=\"pbm-order\"\u003e\n\u003ch3 style=\"margin-top: 0;\"\u003eOrder the Arrow T-POD Responder\u003c\/h3\u003e\n\u003cp\u003eGenuine Teleflex product. Responder (T-PODR) and Combat (T-PODC) variants. Volume and agency pricing available.\u003c\/p\u003e\n\u003cp class=\"pbm-phone\"\u003e844.436.3526\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"mailto:CustomerService@pacificbiomedical.com\"\u003eCustomerService@pacificbiomedical.com\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- JSON-LD STRUCTURED DATA (full set) --\u003e\n\u003cp\u003e\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": [\"Product\", \"MedicalDevice\"],\n  \"name\": \"Arrow T-POD Responder Pelvic Stabilization Device\",\n  \"image\": \"{{IMAGE_URL}}\",\n  \"description\": \"Arrow T-POD Responder (T-PODR): Teleflex pulley-driven pelvic binder for suspected unstable pelvic fractures. Radiolucent, latex-free, single-use.\",\n  \"brand\": { \"@type\": \"Brand\", \"name\": \"Teleflex\" },\n  \"sku\": \"TF-T-PODR\",\n  \"mpn\": \"T-PODR\",\n  \"category\": \"Pelvic Binders\",\n  \"offers\": {\n    \"@type\": \"Offer\",\n    \"url\": \"https:\/\/shop.pacificbiomedical.com\/products\/arrow-t-pod-responder\",\n    \"priceCurrency\": \"USD\",\n    \"price\": \"{{PRICE}}\",\n    \"availability\": \"https:\/\/schema.org\/InStock\",\n    \"seller\": { \"@type\": \"Organization\", \"name\": \"Pacific Biomedical\" }\n  }\n}\n\u003c\/script\u003e \u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Organization\",\n  \"name\": \"Pacific Biomedical\",\n  \"url\": \"https:\/\/shop.pacificbiomedical.com\",\n  \"email\": \"CustomerService@pacificbiomedical.com\",\n  \"telephone\": \"844.436.3526\"\n}\n\u003c\/script\u003e \u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    { \"@type\": \"ListItem\", \"position\": 1, \"name\": \"Home\", \"item\": \"https:\/\/shop.pacificbiomedical.com\" },\n    { \"@type\": \"ListItem\", \"position\": 2, \"name\": \"Pelvic Binders\", \"item\": \"https:\/\/shop.pacificbiomedical.com\/collections\/pelvic-binders\" },\n    { \"@type\": \"ListItem\", \"position\": 3, \"name\": \"Arrow T-POD Responder Pelvic Stabilization Device\", \"item\": \"https:\/\/shop.pacificbiomedical.com\/products\/arrow-t-pod-responder\" }\n  ]\n}\n\u003c\/script\u003e \u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    { \"@type\": \"Question\", \"name\": \"Where should the T-POD be positioned on the pelvis?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"Center the T-POD over the greater trochanters and symphysis pubis — not the iliac crests, a common misplacement that reduces effectiveness. Trim the belt to leave a 15–20 cm gap, then draw tension with the pull tab until snug: two fingers should fit beneath it and the edges should not meet. Internally rotate the legs to complete stabilization.\" } },\n    { \"@type\": \"Question\", \"name\": \"Is the T-POD safe for X-ray, CT, and MRI?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"Yes. The Arrow T-POD has no metallic parts and is radiolucent, so it can remain in place during X-ray, CT, and MRI. Imaging isn't delayed by removing and reapplying the device, and the pelvis stays stabilized throughout assessment, resuscitation, and transfer.\" } },\n    { \"@type\": \"Question\", \"name\": \"When should a pelvic binder be applied — and is it more harm than good?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"Pelvic binders are indicated for hemodynamically unstable patients with a suspicious mechanism or suspected unstable pelvic fracture, applied correctly. The 2025 NAEMSP position statement cautions against routine, universal use and stresses careful patient selection, correct placement, and continuing to search for other bleeding sources — not abandoning binders for the right patient. Applied to patients later found to have no fracture, circumferential binding has minimal adverse effect.\" } },\n    { \"@type\": \"Question\", \"name\": \"What sizes does it fit? Can it be used on large or pediatric patients?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"The T-POD is one-size-fits-all. Trim the belt to fit smaller patients, or join two devices together to create an extra-large binder for bariatric patients. It can also be used for pediatric and small-adult patients as long as the greater-trochanter and symphysis landmarks can be identified for correct placement.\" } },\n    { \"@type\": \"Question\", \"name\": \"Is this an authentic Teleflex product?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"Yes. Pacific Biomedical supplies genuine, factory-fresh Teleflex (Arrow) products sourced through authorized channels, shipped in original manufacturer packaging.\" } },\n    { \"@type\": \"Question\", \"name\": \"How fast does this ship?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"In-stock orders typically ship within one business day. Contact us for expedited shipping, current lead times, or freight on bulk orders.\" } },\n    { \"@type\": \"Question\", \"name\": \"How do I order the Responder or Combat variant, request a quote, or set up an account?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"Add the item to your cart to order the Responder (T-PODR). The black Combat variant (T-PODC) is also available — contact us to order it, or for volume pricing, GPO\/contract pricing, agency purchase orders, and net terms.\" } }\n  ]\n}\n\u003c\/script\u003e \u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"WebPage\",\n  \"url\": \"https:\/\/shop.pacificbiomedical.com\/products\/arrow-t-pod-responder\",\n  \"name\": \"Arrow T-POD Responder Pelvic Stabilization Device\",\n  \"datePublished\": \"2026-07-22\",\n  \"dateModified\": \"2026-07-22\",\n  \"primaryImageOfPage\": \"{{IMAGE_URL}}\"\n}\n\u003c\/script\u003e\u003c\/p\u003e","brand":"Teleflex","offers":[{"title":"Default Title","offer_id":51816231076151,"sku":"TF-T-PODR","price":82.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/7415\/6599\/files\/TPOD.webp?v=1784767030","url":"https:\/\/shop.pacificbiomedical.com\/products\/arrow%c2%ae-t-pod-responder-pelvic-stabilization-device","provider":"Pacific Biomedical","version":"1.0","type":"link"}